A new model of urban cooling demand and heat island application to vertical greenery systems (VGS)

被引:50
作者
Afshari, Afshin [1 ]
机构
[1] Masdar Inst Sci & Technol, Dept Engn Syst & Management, POB 54224, Abu Dhabi, U Arab Emirates
关键词
Thermal network model; Vertical greenery system; Urban heat island; Town energy balance; FLUX-PROFILE RELATIONSHIPS; THERMAL PERFORMANCE; ENERGY USE; SURFACE; FACADE; MICROCLIMATE; COEFFICIENT; TEMPERATURE; VEGETATION; WALLS;
D O I
10.1016/j.enbuild.2017.01.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The relationship between Urban Heat Island (UHI) and energy consumption in buildings has been widely observed and studied. The aim of this paper is to investigate the impact of large-scale deployment of indirect Vertical Greenery Systems (VGS) on the cooling demand of buildings and on the urban micro climate. VGS significantly reduces air temperature and wind speed near the walls. In doing so, it also positively impacts the UHI intensity. This is achieved mainly through the conversion of sensible heat to latent heat mediated by evaporation and transpiration from the VGS foliage. Evapotranspiration is a physically complex phenomenon and its interaction with the building and the urban climate is difficult to model accurately. We propose to use a dynamic nonlinear lumped parameter thermal network model to determine the thermal interactions between the prototypical building, the VGS, the paved road, the urban canopy air and the atmosphere. The model accounts for both sensible and latent exchanges within and outside the building. Solar (short-wave) radiation on building fa ade and road accounts for shading and unlimited diffuse reflections. Long-wave radiation among surfaces and between surfaces and the sky are estimated using view factors and the fully nonlinear Stefan-Bolzmann law. Building envelope infiltration rate and convective heat transfer coefficient vary with wind speed so as to properly reflect the energetic impact of wind speed attenuation near the wall due to the foliage. The thermal and aerodynamic characterization of the vegetation is based on the formulations proposed by Deardorff (1978). The evapotranspiration rate is estimated based on the Penman formula and is driven by the 'vapor pressure deficit' between actual vapor pressure in the ambient air and the saturation vapor pressure assumed to prevail on the surface of leaves. The calculation of sensible and latent heat fluxes between the urban canopy and the first level of the atmosphere considers buoyancy effects, using the coefficients introduced by Mascart et al. (1995). First, a base case model (no VGS) is created and validated using both building energy consumption data and urban air temperature measurements. The validated model is then used to investigate the impact of a large-scale deployment of VGS in the urban context. The weather data and the typical building thermo-physical properties are from the UAE. Comparison of the urban base case to the rural base case (both without VGS) shows a cooling load penalty, due to the UHI, of about 7%. Retrofitting VGS to all buildings in the urban domain of study results in a 5 8% reduction of the cooling load and a dramatic drop of the urban air temperature of about 0.7 0.9 C, reducing the UHI intensity by almost half. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:204 / 217
页数:14
相关论文
共 50 条
  • [31] Remotely sensing the cooling effects of city scale efforts to reduce urban heat island
    Mackey, Christopher W.
    Lee, Xuhui
    Smith, Ronald B.
    BUILDING AND ENVIRONMENT, 2012, 49 : 348 - 358
  • [32] An examination of urban heat island characteristics in a global climate model
    Oleson, K. W.
    Bonan, G. B.
    Feddema, J.
    Jackson, T.
    INTERNATIONAL JOURNAL OF CLIMATOLOGY, 2011, 31 (12) : 1848 - 1865
  • [33] Impact of urban heat island on energy demand in buildings: Local climate zones in Nanjing
    Yang, Xiaoshan
    Peng, Lilliana L. H.
    Jiang, Zhidian
    Chen, Yuan
    Yao, Lingye
    He, Yunfei
    Xu, Tianjing
    APPLIED ENERGY, 2020, 260
  • [34] The urban heat island of London, an empirical model
    Levermore, Geoff
    Parkinson, John
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2019, 40 (03) : 290 - 295
  • [35] The role of structure cooling to reduce the effect of urban heat island in Mumbai
    Dwivedi, Aparna
    Khire, M., V
    Mohan, B. K.
    Shah, Surendra
    ADVANCES IN BUILDING ENERGY RESEARCH, 2019, 13 (02) : 174 - 192
  • [36] On the energy potential of daytime radiative cooling for urban heat island mitigation
    Carlosena, Laura
    Ruiz-Pardo, Alvaro
    Feng, Jie
    Irulegi, Olatz
    Hernandez-Minguillon, Rufino J.
    Santamouris, Mattheos
    SOLAR ENERGY, 2020, 208 : 430 - 444
  • [37] Daytime Radiative Cooling: A Perspective toward Urban Heat Island Mitigation
    Kousis, Ioannis
    D'Amato, Roberto
    Pisello, Anna Laura
    Latterini, Loredana
    ACS ENERGY LETTERS, 2023, 8 (07) : 3239 - 3250
  • [38] A simple method for designation of urban ventilation corridors and its application to urban heat island analysis
    Wong, Man Sing
    Nichol, Janet E.
    To, Pui Hang
    Wang, Jingzhi
    BUILDING AND ENVIRONMENT, 2010, 45 (08) : 1880 - 1889
  • [39] Numerical investigation on the urban heat island in an entire city with an urban porous media model
    Hu, Zhangbao
    Yu, Bingfeng
    Chen, Zhi
    Li, Tiantian
    Liu, Min
    ATMOSPHERIC ENVIRONMENT, 2012, 47 : 509 - 518
  • [40] Effective cooling networks: Optimizing corridors for Urban Heat Island mitigation
    Rezaei, Teimour
    Shen, Xinyuan
    Chaiyarat, Rattanawat
    Pumijumnong, Nathsuda
    REMOTE SENSING APPLICATIONS-SOCIETY AND ENVIRONMENT, 2024, 36