FTIR microscopy of biological cells and tissue: data analysis using resonant Mie scattering (RMieS) EMSC algorithm

被引:109
作者
Bassan, Paul [1 ]
Sachdeva, Ashwin [1 ]
Kohler, Achim [2 ]
Hughes, Caryn [1 ]
Henderson, Alex [1 ]
Boyle, Jonathan [3 ]
Shanks, Jonathan H. [4 ]
Brown, Michael [5 ,6 ]
Clarke, Noel W. [5 ,6 ]
Gardner, Peter [1 ]
机构
[1] Univ Manchester, Manchester Interdisciplinary Bioctr, Manchester M1 7DN, Lancs, England
[2] Nofima Mat, Ctr Biospect & Data Modelling, N-1430 As, Norway
[3] Univ Manchester, Res Applicat & Collaborat Team, IT Serv Res, Manchester M13 9PL, Lancs, England
[4] Christie NHS Fdn Trust, Dept Histopathol, Manchester M20 4BX, Lancs, England
[5] Christie NHS Fdn Trust, Dept Urol, Manchester M20 4BX, Lancs, England
[6] Univ Manchester, Genito Urinary Canc Res Grp, Sch Canc & Enabling Sci, Paterson Inst Canc Res,Manchester Acad Hlth Sci C, Manchester M20 4BX, Lancs, England
关键词
INFRARED-SPECTRA; MICROSPECTROSCOPY; PROSTATE;
D O I
10.1039/c2an16088a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Transmission and transflection infrared microscopy of biological cells and tissue suffer from significant baseline distortions due to scattering effects, predominantly resonant Mie scattering (RMieS). This scattering can also distort peak shapes and apparent peak positions making interpretation difficult and often unreliable. A correction algorithm, the resonant Mie scattering extended multiplicative signal correction (RMieS-EMSC), has been developed that can be used to remove these distortions. The correction algorithm has two key user defined parameters that influence the accuracy of the correction. The first is the number of iterations used to obtain the best outcome. The second is the choice of the initial reference spectrum required for the fitting procedure. The choice of these parameters influences computational time. This is not a major concern when correcting individual spectra or small data sets of a few hundred spectra but becomes much more significant when correcting spectra from infrared images obtained using large focal plane array detectors which may contain tens of thousands of spectra. In this paper we show that, classification of images from tissue can be achieved easily with a few (<10) iterations but a reliable interpretation of the biochemical differences between classes could require more iterations. Regarding the choice of reference spectrum, it is apparent that the more similar it is to the pure absorption spectrum of the sample, the fewer iterations required to obtain an accurate corrected spectrum. Importantly however, we show that using three different non-ideal reference spectra, the same unique correction solution can be obtained.
引用
收藏
页码:1370 / 1377
页数:8
相关论文
共 28 条
  • [1] Bambery K. R., 2011, ANALYST UNPUB
  • [2] RMieS-EMSC correction for infrared spectra of biological cells: Extension using full Mie theory and GPU computing
    Bassan, Paul
    Kohler, Achim
    Martens, Harald
    Lee, Joe
    Jackson, Edward
    Lockyer, Nicholas
    Dumas, Paul
    Brown, Michael
    Clarke, Noel
    Gardner, Peter
    [J]. JOURNAL OF BIOPHOTONICS, 2010, 3 (8-9) : 609 - 620
  • [3] Resonant Mie Scattering (RMieS) correction of infrared spectra from highly scattering biological samples
    Bassan, Paul
    Kohler, Achim
    Martens, Harald
    Lee, Joe
    Byrne, Hugh J.
    Dumas, Paul
    Gazi, Ehsan
    Brown, Michael
    Clarke, Noel
    Gardner, Peter
    [J]. ANALYST, 2010, 135 (02) : 268 - 277
  • [4] Bassan P, 2009, ANALYST, V134, P2484
  • [5] Resonant Mie scattering in infrared spectroscopy of biological materials - understanding the 'dispersion artefact'
    Bassan, Paul
    Byrne, Hugh J.
    Bonnier, Franck
    Lee, Joe
    Dumas, Paul
    Gardner, Peter
    [J]. ANALYST, 2009, 134 (08) : 1586 - 1593
  • [6] Two step resonant Mie scattering correction of infrared micro-spectral data: human lymph node tissue
    Bird, Benjamin
    Miljkovic, Milos
    Diem, Max
    [J]. JOURNAL OF BIOPHOTONICS, 2010, 3 (8-9) : 597 - 608
  • [7] Infrared micro-spectral imaging: distinction of tissue types in axillary lymph node histology
    Bird, Benjamin
    Miljkovic, Milos
    Romeo, Melissa
    Smith, Jennifer
    Stone, Nicholas
    George, Michael
    Diem, Max
    [J]. BMC CLINICAL PATHOLOGY, 2008, 8
  • [8] Metabolic fingerprinting in disease diagnosis: biomedical applications of infrared and Raman spectroscopy
    Ellis, David I.
    Goodacre, Royston
    [J]. ANALYST, 2006, 131 (08) : 875 - 885
  • [9] Infrared spectroscopic imaging for histopathologic recognition
    Fernandez, DC
    Bhargava, R
    Hewitt, SM
    Levin, IW
    [J]. NATURE BIOTECHNOLOGY, 2005, 23 (04) : 469 - 474
  • [10] Synchrotron FTIR analysis of drug treated ovarian A2780 cells: an ability to differentiate cell response to different drugs?
    Flower, Kevin R.
    Khalifa, Intisar
    Bassan, Paul
    Demoulin, Damien
    Jackson, Edward
    Lockyer, Nicholas P.
    McGown, Alan T.
    Miles, Philip
    Vaccari, Lisa
    Gardner, Peter
    [J]. ANALYST, 2011, 136 (03) : 498 - 507