Comparison of Intraoperative Motor Evoked Potentials Monitoring with Direct Cranial Stimulation by Peg-Screw and Transcranial Stimulation by Corkscrew for Supratentorial Surgery

被引:1
作者
Kanaya, Kohei [1 ]
Goto, Tetsuya [1 ]
Horiuchi, Tetsuyoshi [1 ]
Hongo, Kazuhiro [1 ]
机构
[1] Shinshu Univ, Sch Med, Dept Neurosurg, Matsumoto, Nagano, Japan
关键词
Corkscrew electrode; Motor evoked potentials; Motor threshold; Peg-screw electrode; Transcranial electrical stimulation; ELECTRICAL-STIMULATION; ANEURYSM SURGERY; TUMOR SURGERY; ELECTRODE; RESECTION;
D O I
10.1016/j.wneu.2019.04.039
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: Corkscrew (CS) electrodes are usually used for transcranial electrical stimulation (TES) in the intraoperative monitoring of motor evoked potentials (MEP). Direct cranial stimulation with peg-screw (PS) electrodes can elicit MEP. The present study investigated the difference in the initial threshold between PS and CS electrodes for intraoperative MEP monitoring. METHODS: We retrospectively analyzed TES-MEP monitoring for supratentorial surgery in 72 patients. Of these 72 patients, 44 were monitored with PS and CS electrodes (PS/CS group) and 28 were monitored with CS and CS electrodes (CS/CS group). TES was used to deliver electrical stimulation by a train of 4-pulse anodel constant current stimulation. The initial threshold in each electrode was checked and analyzed. RESULTS: In the PS/CS group, the initial threshold with the PS electrode was 38.3 +/- 15.1 mA (mean +/- standard deviation) on the affected side, and the initial threshold with the CS electrode was 51.4 +/- 13.9 mA on the unaffected side. The initial threshold with the PS electrode was significantly lower than that with the CS electrode (P = 0.0001). In the CS/CS group, the initial threshold was 56.2 +/- 16.5 mA on the affected side and 62.1 +/- 18.6 mA on the unaffected side, with no statistically significant difference (P = 0.23). CONCLUSION: The initial threshold to elicit MEP was significantly lower with the PS electrode than with the CS electrode. A PS electrode can be used as a feasible stimulation electrode for TES-MEP.
引用
收藏
页码:E1044 / E1050
页数:7
相关论文
共 50 条
[31]   Stimulation parameters for motor evoked potentials during intraoperative spinal cord monitoring. A systematic review [J].
Dulfer, S. E. ;
Gadella, M. C. ;
Sahinovic, M. M. ;
Lange, F. ;
Absalom, A. R. ;
Groen, R. J. M. ;
Szelenyi, A. ;
Drost, G. .
CLINICAL NEUROPHYSIOLOGY, 2023, 149 :70-80
[32]   Direct Cortical Motor Evoked Potentials Versus Transcranial Motor Evoked Potentials for the Detection of Cortical Ischemia During Supratentorial Craniotomy: Case Report [J].
Silverstein, Justin W. ;
Rosenthal, Andrew ;
Ellis, Jason A. .
CUREUS, 2018, 10 (12)
[33]   Effects of carotid endarterectomy on motor evoked potentials elicited by transcranial magnetic stimulation [J].
G. Katsoulas ;
I. Tsolakis ;
A. A. Argyriou ;
P. Polychronopoulos ;
M. Argentou ;
E. Chroni .
Journal of Neurology, 2005, 252 :1050-1054
[34]   Effects of carotid endarterectomy on motor evoked potentials elicited by transcranial magnetic stimulation [J].
Katsoulas, G ;
Tsolakis, I ;
Argyriou, AA ;
Polychronopoulos, P ;
Argentou, M ;
Chroni, E .
JOURNAL OF NEUROLOGY, 2005, 252 (09) :1050-1054
[35]   Comparison of navigated and non-navigated transcranial magnetic stimulation for motor cortex mapping, motor threshold and motor evoked potentials [J].
Julkunen, Petro ;
Saisanen, Laura ;
Danner, Nils ;
Niskanen, Eini ;
Hukkanen, Taina ;
Mervaala, Esa ;
Kononen, Mervi .
NEUROIMAGE, 2009, 44 (03) :790-795
[36]   Threshold-level multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: description of method and comparison to somatosensory evoked potential monitoring [J].
Calancie, B ;
Harris, W ;
Broton, JG ;
Alexeeva, N ;
Green, BA .
JOURNAL OF NEUROSURGERY, 1998, 88 (03) :457-470
[37]   Significance of intraoperative motor function monitoring using transcranial electrical motor evoked potentials (MEP) in patients with spinal and cranial lesions near the motor pathways [J].
Krammer, Matthias Johannes ;
Wolf, Stefan ;
Schul, David Baruch ;
Gerstner, Werner ;
Lumenta, Christianto Bernardo .
BRITISH JOURNAL OF NEUROSURGERY, 2009, 23 (01) :48-55
[38]   Incidence and linguistic quality of speech errors: a comparison of preoperative transcranial magnetic stimulation and intraoperative direct cortex stimulation [J].
Baehrend, Ina ;
Muench, Max R. ;
Schneider, Heike ;
Moshourab, Rabih ;
Dreyer, Felix R. ;
Vajkoczy, Peter ;
Picht, Thomas ;
Faust, Katharina .
JOURNAL OF NEUROSURGERY, 2020, 134 (05) :1409-1418
[39]   Bite injuries caused by transcranial electrical stimulation motor-evoked potentials’ monitoring: incidence, associated factors, and clinical course [J].
Sachiko Yata ;
Mitsuru Ida ;
Hiroko Shimotsuji ;
Yosuke Nakagawa ;
Nobuhiro Ueda ;
Tsunenori Takatani ;
Hideki Shigematsu ;
Yasushi Motoyama ;
Hiroyuki Nakase ;
Tadaaki Kirita ;
Masahiko Kawaguchi .
Journal of Anesthesia, 2018, 32 :844-849
[40]   Comparison of motor-evoked potentials monitoring in response to transcranial electrical stimulation in subjects undergoing neurosurgery with partial vs no neuromuscular block [J].
Kim, W. H. ;
Lee, J. J. ;
Lee, S. M. ;
Park, M. N. ;
Park, S. K. ;
Seo, D. W. ;
Chung, I. S. .
BRITISH JOURNAL OF ANAESTHESIA, 2013, 110 (04) :567-576