Efficient tandem solid-phase extraction and liquid chromatography-triple quadrupole mass spectrometry method to determine polar benzotriazole, benzothiazole and benzenesulfonamide contaminants in environmental water samples

被引:59
|
作者
Herrero, P. [1 ]
Borrull, F. [1 ]
Pocurull, E. [1 ]
Marce, R. M. [1 ]
机构
[1] Univ Rovira & Virgili, Dept Analyt Chem & Organ Chem, E-43007 Tarragona, Spain
关键词
Benzotriazole derivates; Benzothiazole derivates; Benzenesulfonamide derivates; Liquid chromatography-tandem mass spectrometry; Solid-phase extraction; Environmental waters; MUNICIPAL WASTE-WATER; PRESSURE CHEMICAL-IONIZATION; BAR SORPTIVE EXTRACTION; AQUEOUS MATRICES; ELECTROSPRAY-IONIZATION; CORROSION-INHIBITORS; ULTRAVIOLET FILTERS; SULFONAMIDES; POLLUTANTS; RIVER;
D O I
10.1016/j.chroma.2013.08.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An analytical method has been developed that allows the simultaneous determination of five benzotriazole (BTRs), four benzothiazole (BTs) and five benzenesulfonamide (BSAs) derivates. The method is based on tandem solid-phase extraction (SPE) with Oasis HLB followed by a clean-up step with Florisil. The chromatographic analysis was performed in less than 15 min and detection was carried out with a triple quadrupole mass analyser operating in multiple reaction monitoring (MRM) mode. A comparison was performed between Oasis HLB and Oasis MAX sorbents for the solid-phase extraction, with Oasis HLB being the sorbent that gave the highest recoveries, ranging between 75% and 106%, depending on the compound and the matrix analysed. The proposed clean-up with Florisil sorbent reduced the matrix effect to below 20%. The repeatability (%RSD, 50-3000 ng/L, n = 3) of the method was less than 15% for all of the compounds in all of the matrices. The limits of detection (LODs) achieved ranged from 1 ng/L for BTR in river water up to 100 ng/L for BT in influent sewage. All of the compounds were determined in environmental waters such as river water and sewage. The highest concentrations determined corresponded to influent sewage samples in which the sum of concentrations for all compounds were between 4.6 mu g/L and 8.0 mu g/L. These concentrations were slightly reduced in secondary effluent and tertiary effluent sewage. Moreover, samples from tertiary effluent sewage based on ultra-filtration membrane treatments were also analysed and preliminary results seem to indicate that these treatments may be most effective for removing BTR, BT and BSA derivates. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 50 条
  • [21] Determination of MS-222 in Water Samples by Solid-phase Extraction Coupled with Liquid Chromatography/Tandem Mass Spectrometry
    Zhao, Dong-Hao
    Wang, Qiang
    Wang, Xu-Feng
    Li, Zhi-Guang
    Li, Yong-Xian
    Huang, Ke
    Li, Liu-Dong
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2017, 55 (08) : 813 - 817
  • [22] Determination of polycyclic aromatic hydrocarbons in water samples by gas chromatography coupled to triple quadrupole tandem mass spectrometry using macroporous resin solid-phase extraction
    Xing, Yan
    Wang, Min
    Li, Tingting
    Fu, Yin Xu
    Wang, Xu
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (11) : 2453 - 2460
  • [23] Simultaneous liquid-liquid extraction and dispersive solid-phase extraction as a sample preparation method to determine acidic contaminants in river water by gas chromatography/mass spectrometry
    Jimenez, Juan J.
    TALANTA, 2013, 116 : 678 - 687
  • [24] Multianalyte method for the determination of pharmaceuticals in wastewater samples using solid-phase extraction and liquid chromatography–tandem mass spectrometry
    Marilena E. Dasenaki
    Nikolaos S. Thomaidis
    Analytical and Bioanalytical Chemistry, 2015, 407 : 4229 - 4245
  • [25] Selective determination of sartan drugs in environmental water samples by mixed-mode solid-phase extraction and liquid chromatography tandem mass spectrometry
    Castro, G.
    Rodriguez, I.
    Ramil, M.
    Cela, R.
    CHEMOSPHERE, 2019, 224 : 562 - 571
  • [26] Solid-phase extraction followed by liquid chromatography-tandem mass spectrometry for the determination of hydroxylated benzophenone UV absorbers in environmental water samples
    Negreira, N.
    Rodriguez, I.
    Ramil, M.
    Rubi, E.
    Cela, R.
    ANALYTICA CHIMICA ACTA, 2009, 654 (02) : 162 - 170
  • [27] Development of a Multiresidue Method for Pesticide Analysis in Drinking Water by Solid Phase Extraction and Determination by Gas and Liquid Chromatography with Triple Quadrupole Tandem Mass Spectrometry
    Donato, Filipe F.
    Martins, Manoel L.
    Munaretto, Juliana S.
    Prestes, Osmar D.
    Adaime, Martha B.
    Zanella, Renato
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (10) : 2077 - 2087
  • [28] Comprehensive analysis of synthetic cannabinoids and metabolites in oral fluid by online solid-phase extraction coupled to liquid chromatography-triple quadrupole-mass spectrometry
    Carmen T. Mulet
    Anamary Tarifa
    Anthony P. DeCaprio
    Analytical and Bioanalytical Chemistry, 2020, 412 : 7937 - 7953
  • [29] Comprehensive analysis of synthetic cannabinoids and metabolites in oral fluid by online solid-phase extraction coupled to liquid chromatography-triple quadrupole-mass spectrometry
    Mulet, Carmen T.
    Tarifa, Anamary
    DeCaprio, Anthony P.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (28) : 7937 - 7953
  • [30] Simultaneous determination of benzotriazole and benzothiazole derivatives in aqueous matrices by mixed-mode solid-phase extraction followed by liquid chromatography-tandem mass spectrometry
    Carpinteiro, I.
    Abuin, B.
    Ramil, M.
    Rodriguez, I.
    Cela, R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (07) : 2471 - 2478