Ultrasonography Monitoring of Optic Nerve Sheath Diameter and Retinal Vessels in Patients with Cerebral Hemorrhage

被引:31
|
作者
Naldi, Andrea [1 ]
Pivetta, Emanuele [2 ,3 ,4 ,5 ]
Coppo, Lorenzo [6 ]
Cantello, Roberto [6 ]
Comi, Cristoforo [6 ]
Stecco, Alessandro [7 ]
Cerrato, Paolo [1 ]
Lesmeister, Martin [8 ]
Lochner, Piergiorgio [8 ]
机构
[1] City Hlth & Sci Univ Hosp Turin, Stroke Unit, Turin, Italy
[2] Univ Turin, Canc Epidemiol Unit, Dept Med Sci, Turin, Italy
[3] Univ Turin, CPO Unit, Dept Med Sci, Turin, Italy
[4] Univ Turin, Div Emergency Med, Dept Med Sci, Turin, Italy
[5] Univ Turin, High Dependency Unit, Dept Med Sci, Turin, Italy
[6] Univ Piemonte Orientale, Neurol Unit, Dept Translat Med, Novara, Italy
[7] Univ Piemonte Orientale, Neuroradiol Unit, Novara, Italy
[8] Saarland Univ, Dept Neurol, Med Ctr, Kirrberger Str 100, D-66421 Homburg, Germany
关键词
intracerebral hemorrhage; intracranial pressure; optic nerve sheath diameter; retinal vessels; TRANSCRANIAL DOPPLER ULTRASONOGRAPHY; RAISED INTRACRANIAL-PRESSURE; HYPERACUTE STAGE; SONOGRAPHY; PULSATILITY; ULTRASOUND; EYE;
D O I
10.1111/jon.12604
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE Evaluation of the diagnostic accuracy of optic nerve sheath diameter (ONSD) and Doppler indices of central retinal arteries and veins for the detection of increased intracranial pressure (ICP) in intracerebral hemorrhage (ICH) and of the usefulness of a second assessment of these variables in the monitoring of ICH. METHODS A total of 46 acute ICH patients with (group 1, n = 25) and without (group 2, n = 21) clinical and radiological computed tomography signs of raised ICP and 40 healthy controls were recruited. The median binocular ONSD and Doppler indices of retinal vessels including resistive index (RI) and retinal venous pulsation (RVP) were compared among groups, both at admission and later during ICH monitoring. RESULTS Median binocular ONSD showed higher accuracy for the detection of increased ICP (sensitivity and specificity 100%), while Doppler indices were less accurate (sensitivity 48% and specificity 95% for RI; 80% and 62% for RVP). In ICH patients, ONSD was significantly elevated in group 1 both at admission (6.40 mm [interquartile range [IQR] = .70] vs. 4.70 [.40]) and at control time (6.00 [.55] vs. 4.55 [.40]; P < .01), as well as RI (.79 [.11] vs. .77 [.03] and .80 [.06] vs. .75 [.35]; P = .01). RVP was significantly increased in group 1 only at admission (3.20 cm/s [1.05] vs. 2.00 [1.55], P = .02). CONCLUSIONS Median binocular ONSD evaluation showed higher accuracy for the estimation of elevated ICP compared with Doppler indices of retinal vessels. The ONSD enlargement detected in the early phase of ICH persists at control time.
引用
收藏
页码:394 / 399
页数:6
相关论文
共 50 条
  • [41] Optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in prediction of malignant progression in ischemic stroke
    Guo, Yuan
    Chen, Yinjuan
    Shen, Chaoxiong
    Fan, Daofeng
    Hu, Xiaohong
    Duan, Jiaojiao
    Chen, Yangui
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [42] Prediction of Intracranial Pressure in Patients with an Aneurysmal Subarachnoid Hemorrhage Using Optic Nerve Sheath Diameter via Explainable Predictive Modeling
    Kim, Kwang Hyeon
    Kang, Hyung Koo
    Koo, Hae-Won
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (07)
  • [43] Optic nerve sheath diameter measurements using ultrasonography to diagnose raised intracranial pressure in preeclampsia: an observational study
    Biswas, Jhuma
    Khatun, Nasima
    Bandyopadhyay, Rakhi
    Bhattacharya, Namrata
    Maitra, Arghya
    Mukherjee, Sayan
    Mondal, Swarnakamal
    JOURNAL OF THE TURKISH-GERMAN GYNECOLOGICAL ASSOCIATION, 2023, 24 (01) : 5 - 11
  • [44] Monitoring of Intracranial Pressure by CT-Defined Optic Nerve Sheath Diameter
    Bekerman, Inessa
    Kimiagar, Itzhak
    Sigal, Tal
    Vaiman, Michael
    JOURNAL OF NEUROIMAGING, 2016, 26 (03) : 309 - 314
  • [45] Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial Pressure
    Agrawal, Ashish
    Cheng, Roger
    Tang, Julin
    Madhok, Debbie Y.
    CRITICAL CARE MEDICINE, 2019, 47 (06) : E495 - E501
  • [46] High-fidelity Training Model for Measurement of Dynamic Optic Nerve Sheath Diameter Using Transorbital Ultrasonography
    Hajat, Zakir
    Dinsmore, Michael
    Venkatraghavan, Lashmi
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 2020, 32 (03) : 256 - 262
  • [47] Optic nerve sheath diameter in patients with hepatic encephalopathy
    Colak, Nese
    Basakci, Ozlem Bayrak
    Bayram, Basak
    Aksay, Ersin
    Simsek, Muhammet Kursat
    Karabay, Nuri
    PLOS ONE, 2022, 17 (11):
  • [48] ULTRASONOGRAPHIC EVALUATION OF OPTIC NERVE SHEATH DIAMETER AMONG HEALTHY CHINESE ADULTS
    Wang, Lijuan
    Feng, Liangshu
    Yao, Yan
    Deng, Fang
    Wang, Yuzhi
    Feng, Jiachun
    Xing, Yingqi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (03) : 683 - 688
  • [49] Assessing ultrasonographic optic nerve sheath diameter in animal model with anesthesia regimens
    Azevedo, Maira de Robertis
    de-Lima-Oliveira, Marcelo
    Belon, Alessandro Rodrigo
    Brasil, Sergio
    Teixeira, Manoel Jacobsen
    Paiva, Wellingson Silva
    Bor-Seng-Shu, Edson
    ACTA CIRURGICA BRASILEIRA, 2022, 37 (03)
  • [50] Measurement of Optic Nerve Sheath Diameter: Differences between Methods? A Pilot Study
    Giger-Tobler, C.
    Eisenack, J.
    Holzmann, D.
    Pangalu, A.
    Sturm, V.
    Killer, H. E.
    Landau, K.
    Jaggi, G. P.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2015, 232 (04) : 467 - 470