Ultrasonography Monitoring of Optic Nerve Sheath Diameter and Retinal Vessels in Patients with Cerebral Hemorrhage

被引:31
|
作者
Naldi, Andrea [1 ]
Pivetta, Emanuele [2 ,3 ,4 ,5 ]
Coppo, Lorenzo [6 ]
Cantello, Roberto [6 ]
Comi, Cristoforo [6 ]
Stecco, Alessandro [7 ]
Cerrato, Paolo [1 ]
Lesmeister, Martin [8 ]
Lochner, Piergiorgio [8 ]
机构
[1] City Hlth & Sci Univ Hosp Turin, Stroke Unit, Turin, Italy
[2] Univ Turin, Canc Epidemiol Unit, Dept Med Sci, Turin, Italy
[3] Univ Turin, CPO Unit, Dept Med Sci, Turin, Italy
[4] Univ Turin, Div Emergency Med, Dept Med Sci, Turin, Italy
[5] Univ Turin, High Dependency Unit, Dept Med Sci, Turin, Italy
[6] Univ Piemonte Orientale, Neurol Unit, Dept Translat Med, Novara, Italy
[7] Univ Piemonte Orientale, Neuroradiol Unit, Novara, Italy
[8] Saarland Univ, Dept Neurol, Med Ctr, Kirrberger Str 100, D-66421 Homburg, Germany
关键词
intracerebral hemorrhage; intracranial pressure; optic nerve sheath diameter; retinal vessels; TRANSCRANIAL DOPPLER ULTRASONOGRAPHY; RAISED INTRACRANIAL-PRESSURE; HYPERACUTE STAGE; SONOGRAPHY; PULSATILITY; ULTRASOUND; EYE;
D O I
10.1111/jon.12604
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE Evaluation of the diagnostic accuracy of optic nerve sheath diameter (ONSD) and Doppler indices of central retinal arteries and veins for the detection of increased intracranial pressure (ICP) in intracerebral hemorrhage (ICH) and of the usefulness of a second assessment of these variables in the monitoring of ICH. METHODS A total of 46 acute ICH patients with (group 1, n = 25) and without (group 2, n = 21) clinical and radiological computed tomography signs of raised ICP and 40 healthy controls were recruited. The median binocular ONSD and Doppler indices of retinal vessels including resistive index (RI) and retinal venous pulsation (RVP) were compared among groups, both at admission and later during ICH monitoring. RESULTS Median binocular ONSD showed higher accuracy for the detection of increased ICP (sensitivity and specificity 100%), while Doppler indices were less accurate (sensitivity 48% and specificity 95% for RI; 80% and 62% for RVP). In ICH patients, ONSD was significantly elevated in group 1 both at admission (6.40 mm [interquartile range [IQR] = .70] vs. 4.70 [.40]) and at control time (6.00 [.55] vs. 4.55 [.40]; P < .01), as well as RI (.79 [.11] vs. .77 [.03] and .80 [.06] vs. .75 [.35]; P = .01). RVP was significantly increased in group 1 only at admission (3.20 cm/s [1.05] vs. 2.00 [1.55], P = .02). CONCLUSIONS Median binocular ONSD evaluation showed higher accuracy for the estimation of elevated ICP compared with Doppler indices of retinal vessels. The ONSD enlargement detected in the early phase of ICH persists at control time.
引用
收藏
页码:394 / 399
页数:6
相关论文
共 50 条
  • [31] Optic nerve sheath diameter ultrasonography for elevated intracranial pressure detection
    Wang Li-Juan
    Chen Hong-Xiu
    Chen Ying
    Yu Ze-Yang
    Xing Ying-Qi
    ANNALS OF CLINICAL AND TRANSLATIONAL NEUROLOGY, 2020, 7 (05): : 865 - 868
  • [32] Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
    Yanamandra, Uday
    Gupta, Amul
    Bhattachar, Srinivasa A.
    Yanamandra, Sushma
    Das, Subrat K.
    Patyal, Sagarika
    Grewal, Rajan
    Nair, Velu
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2018, 22 (03) : 150 - 153
  • [33] Bedside Ultrasonography as an Alternative to Computed Tomography Scan for the Measurement of Optic Nerve Sheath Diameter
    Yanamandra, Uday
    Gupta, Amul
    Yanamandra, Sushma
    Das, Subrat Kumar
    Patyal, Sagarika
    Nair, Velu
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2018, 9 (02) : 252 - 255
  • [34] Evaluation of postictal optic nerve sheath diameter at epileptic patients
    Gunsay, Rabia Handan
    Isik, Gulash Cikrikci
    Yildirim, Meral
    Gokcek, Ozcan
    Korucu, Osman
    Cevik, Yunsur
    EPILEPSY & BEHAVIOR, 2023, 144
  • [35] Ultrasonic measurement of optic nerve sheath diameter in elderly patients with craniocerebral injury
    Qiao, Zhifei
    Wang, Lei
    Li, Shutie
    Li, Yuanli
    Gao, Naikun
    Jia, Liqun
    Liu, Chunyan
    Zhai, Liping
    Li, Fulong
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (04): : 3466 - 3472
  • [36] Optic nerve sheath diameter measurement by ultrasound: Evaluation of a standardized protocol
    Pansell, Jakob
    Bell, Max
    Rudberg, Peter
    Friman, Ola
    Cooray, Charith
    JOURNAL OF NEUROIMAGING, 2022, 32 (01) : 104 - 110
  • [37] Retrospective longitudinal assessment of optic nerve sheath diameter in patients with malignant glioma
    Feucht, Daniel
    Kerscher, Susanne R.
    Ruff, Christer
    Schuhmann, Martin U.
    Roder, Constantin
    Zipfel, Julian
    CANCER MEDICINE, 2023, 12 (24): : 22047 - 22055
  • [38] Optic nerve sheath diameter asymmetry in healthy subjects and patients with intracranial hypertension
    Naldi, Andrea
    Provero, Paolo
    Vercelli, Alessandro
    Bergui, Mauro
    Mazzeo, Anna Teresa
    Cantello, Roberto
    Tondo, Giacomo
    Lochner, Piergiorgio
    NEUROLOGICAL SCIENCES, 2020, 41 (02) : 329 - 333
  • [39] Echographic evaluation of optic nerve sheath diameter in malarial patients
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nicola
    JOURNAL OF ULTRASOUND, 2019, 22 (03) : 407 - 407
  • [40] Echographic evaluation of optic nerve sheath diameter in malarial patients
    Maddalena De Bernardo
    Livio Vitiello
    Nicola Rosa
    Journal of Ultrasound, 2019, 22 : 407 - 407