Ultrasonography Monitoring of Optic Nerve Sheath Diameter and Retinal Vessels in Patients with Cerebral Hemorrhage

被引:31
|
作者
Naldi, Andrea [1 ]
Pivetta, Emanuele [2 ,3 ,4 ,5 ]
Coppo, Lorenzo [6 ]
Cantello, Roberto [6 ]
Comi, Cristoforo [6 ]
Stecco, Alessandro [7 ]
Cerrato, Paolo [1 ]
Lesmeister, Martin [8 ]
Lochner, Piergiorgio [8 ]
机构
[1] City Hlth & Sci Univ Hosp Turin, Stroke Unit, Turin, Italy
[2] Univ Turin, Canc Epidemiol Unit, Dept Med Sci, Turin, Italy
[3] Univ Turin, CPO Unit, Dept Med Sci, Turin, Italy
[4] Univ Turin, Div Emergency Med, Dept Med Sci, Turin, Italy
[5] Univ Turin, High Dependency Unit, Dept Med Sci, Turin, Italy
[6] Univ Piemonte Orientale, Neurol Unit, Dept Translat Med, Novara, Italy
[7] Univ Piemonte Orientale, Neuroradiol Unit, Novara, Italy
[8] Saarland Univ, Dept Neurol, Med Ctr, Kirrberger Str 100, D-66421 Homburg, Germany
关键词
intracerebral hemorrhage; intracranial pressure; optic nerve sheath diameter; retinal vessels; TRANSCRANIAL DOPPLER ULTRASONOGRAPHY; RAISED INTRACRANIAL-PRESSURE; HYPERACUTE STAGE; SONOGRAPHY; PULSATILITY; ULTRASOUND; EYE;
D O I
10.1111/jon.12604
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE Evaluation of the diagnostic accuracy of optic nerve sheath diameter (ONSD) and Doppler indices of central retinal arteries and veins for the detection of increased intracranial pressure (ICP) in intracerebral hemorrhage (ICH) and of the usefulness of a second assessment of these variables in the monitoring of ICH. METHODS A total of 46 acute ICH patients with (group 1, n = 25) and without (group 2, n = 21) clinical and radiological computed tomography signs of raised ICP and 40 healthy controls were recruited. The median binocular ONSD and Doppler indices of retinal vessels including resistive index (RI) and retinal venous pulsation (RVP) were compared among groups, both at admission and later during ICH monitoring. RESULTS Median binocular ONSD showed higher accuracy for the detection of increased ICP (sensitivity and specificity 100%), while Doppler indices were less accurate (sensitivity 48% and specificity 95% for RI; 80% and 62% for RVP). In ICH patients, ONSD was significantly elevated in group 1 both at admission (6.40 mm [interquartile range [IQR] = .70] vs. 4.70 [.40]) and at control time (6.00 [.55] vs. 4.55 [.40]; P < .01), as well as RI (.79 [.11] vs. .77 [.03] and .80 [.06] vs. .75 [.35]; P = .01). RVP was significantly increased in group 1 only at admission (3.20 cm/s [1.05] vs. 2.00 [1.55], P = .02). CONCLUSIONS Median binocular ONSD evaluation showed higher accuracy for the estimation of elevated ICP compared with Doppler indices of retinal vessels. The ONSD enlargement detected in the early phase of ICH persists at control time.
引用
收藏
页码:394 / 399
页数:6
相关论文
共 50 条
  • [21] A New Inexpensive Simulation Model for Ultrasound Assessment of Optic Nerve Sheath Diameter
    Johnson, Garrett G. R. J.
    Jelic, Tomislav
    Derksen, Angela
    Unger, Bertram
    Zeiler, Frederick
    Ziesmann, Markus
    Gillman, Lawrence M.
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2020, 47 (04) : 543 - 548
  • [22] Optic Nerve Sheath Diameter is not Related to Intracranial Pressure in Subarachnoid Hemorrhage Patients
    Tommaso Zoerle
    Alessio Caccioppola
    Eleonora D’Angelo
    Marco Carbonara
    Giorgio Conte
    Sabrina Avignone
    Elisa R. Zanier
    Tatiana Birg
    Fabrizio Ortolano
    Fabio Triulzi
    Nino Stocchetti
    Neurocritical Care, 2020, 33 : 491 - 498
  • [23] Determination of normal values of optic nerve sheath diameter in newborns with bedside ultrasonography
    Yapicioglu, Hacer
    Aslan, Nagehan
    Sertdemir, Yasar
    Yildizdas, Dincer
    Gulasi, Selvi
    Mert, Kurthan
    EARLY HUMAN DEVELOPMENT, 2020, 145
  • [24] Correlation of optic nerve sheath diameter with intracranial pressure monitoring in patients with severe traumatic brain injury
    Sahoo, Siddhartha Shankar
    Agrawal, Deepak
    INDIAN JOURNAL OF NEUROTRAUMA, 2013, 10 (01) : 9 - 12
  • [25] Measuring optic nerve sheath diameter using ultrasonography in patients with idiopathic intracranial hypertension
    Dagdelen, Kenan
    Ekici, Merve
    ARQUIVOS DE NEURO-PSIQUIATRIA, 2022, 80 (06) : 580 - 585
  • [26] The clinical and prognostic values of optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in comatose patients with supratentorial lesions
    Zhu, Sha
    Cheng, Chao
    Zhao, Dianjiang
    Zhao, Yuanli
    Liu, Xianzeng
    Zhang, Jun
    BMC NEUROLOGY, 2021, 21 (01)
  • [27] The clinical and prognostic values of optic nerve sheath diameter and optic nerve sheath diameter/eyeball transverse diameter ratio in comatose patients with supratentorial lesions
    Sha Zhu
    Chao Cheng
    Dianjiang Zhao
    Yuanli Zhao
    Xianzeng Liu
    Jun Zhang
    BMC Neurology, 21
  • [28] Optic nerve sheath diameter ultrasonography in differentiation of ischemic and hemorrhagic strokes
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nicola
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2019, 37 (07) : 1384 - 1385
  • [29] Measuring the Optic Nerve Sheath Diameter with Ultrasound in Acute Middle Cerebral Artery Stroke Patients
    Guzeldag, Seda
    Yilmaz, Gokhan
    Tuna, Merva
    Altuntas, Mukerrem
    Ozdemir, Mustafa
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2021, 30 (02)
  • [30] Association Between Optic Nerve Sheath Diameter and Mortality in Patients with Severe Traumatic Brain Injury
    Sekhon, Mypinder S.
    McBeth, Paul
    Zou, Jie
    Qiao, Lu
    Kolmodin, Leif
    Henderson, William R.
    Reynolds, Steve
    Griesdale, Donald E. G.
    NEUROCRITICAL CARE, 2014, 21 (02) : 245 - 252