A Multispectral Three-Dimensional Acquisition Technique for Imaging Near Metal Implants

被引:218
作者
Koch, Kevin M. [1 ]
Lorbiecki, John. E. [1 ]
Hinks, R. Scott [1 ]
King, Kevin F. [1 ]
机构
[1] GE Healthcare, Appl Sci Lab, Waukesha, WI 53188 USA
关键词
MRI of arthroplasty; metal implants; image artifacts; 3D imaging; TOTAL HIP-ARTHROPLASTY; KNEE ARTHROPLASTY; UNITED-STATES; IN-VITRO; MRI; OSTEOLYSIS; RECONSTRUCTION; INSTRUMENTS; REDUCTION; TISSUE;
D O I
10.1002/mrm.21856
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Metallic Implants used In bone and joint arthroplasty Induce severe spatial perturbations to the B-0 magnetic field used for high-field clinical magnetic resonance. These perturbations distort slice-selection and frequency encoding processes applied In conventional two-dimensional MRI techniques and hinder the diagnosis of complications from arthroplasty. Here, a method is presented whereby multiple three-dimensional fast-spin-echo Images are collected using discrete offsets In RF transmission and reception frequency. It Is demonstrated that this multi acquisition variable-resonance Image combination technique can be used to generate a composite image that is devoid of slice-plane distortion and possesses greatly reduced distortions In the readout direction, even in the Immediate vicinity of metallic Implants. Magn Reson Mad 61:381-390, 2009. (c) 2009 Wiley-Liss, Inc.
引用
收藏
页码:381 / 390
页数:10
相关论文
共 31 条
  • [1] BEATTY PJ, 2006, P 14 ANN M ISMRM SEA, P2462
  • [2] Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods
    Brau, Anja C. S.
    Beatty, Philip J.
    Skare, Stefan
    Bammer, Roland
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) : 382 - 395
  • [3] Reduction of blurring in view angle tilting MRI
    Butts, K
    Pauly, JM
    Gold, GE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (02) : 418 - 424
  • [4] Butts K, 1999, JMRI-J MAGN RESON IM, V9, P586, DOI 10.1002/(SICI)1522-2586(199904)9:4<586::AID-JMRI13>3.0.CO
  • [5] 2-X
  • [6] Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information
    Candès, EJ
    Romberg, J
    Tao, T
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) : 489 - 509
  • [7] Compressed sensing
    Donoho, DL
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) : 1289 - 1306
  • [8] Gallo Jiri, 2002, Biomedical Papers (Olomouc), V146, P21
  • [9] Effects on MRI due to altered rf polarization near conductive implants or instruments
    Graf, H
    Steidle, G
    Martirosian, P
    Lauer, UA
    Schick, F
    [J]. MEDICAL PHYSICS, 2006, 33 (01) : 124 - 127
  • [10] RF aitifacts caused by metallic implants or instruments which get more prominent at 3 T: an in vitro study
    Graf, H
    Lauer, UA
    Berger, A
    Schick, F
    [J]. MAGNETIC RESONANCE IMAGING, 2005, 23 (03) : 493 - 499