Development of a near-infrared spectroscopy instrument for applications in urology

被引:0
|
作者
Macnab, Andrew J. [1 ]
Stothers, Lynn [1 ]
机构
[1] Univ British Columbia, Univ British Columbia Hosp, Bladder Care Ctr, Dept Urol Sci,Unit 1B, Vancouver, BC V6T 2B5, Canada
关键词
chromophores; urodynamics; detrusor; oxyhemoglobin; deoxyhemoglobin;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Near infrared spectroscopy (NIRS) is an established technology using photons of light in the near infrared spectrum to monitor changes in tissue of naturally occurring chromophores, including oxygenated and deoxygenated hemoglobin. Technology and methodology have been validated for measurement of a range of physiologic parameters. NIRS has been applied successfully in urology research; however current instruments are designed principally for brain and muscle study. Objective: To describe development of a NIRS instrument specifically designed for monitoring changes in chromophore concentration in the bladder detrusor in real time, to facilitate research to establish the role of this non-invasive technology in the evaluation of patients with voiding dysfunction Method: The portable continuous wave NIRS instrument has a 3 laser diode light source (785, 808 and 830 nanometers), fiber optic cables for light transmission, a self adhesive patient interface patch with an en-titter and sensor, and software to detect the difference between the light transmitted and received by the instrument. Software incorporated auto-attenuates the optical signals and converts raw optical data into chromophore concentrations displayed graphically. Results: The prototype was designed, tested, and iteratively developed to achieve optimal suprapubic transcutaneous monitoring of the detrusor in human subjects during bladder filling and emptying. Evaluation with simultaneous invasive urodynamic measurement in men and women indicates good specificity and sensitivity of NIRS chromophore concentration changes by receiver operator curve analysis, and correlation between NIRS data and urodynamic pressures. Conclusion: Urological monitoring with this NIRS instrument is feasible and generates data of potential diagnostic value.
引用
收藏
页码:4233 / 4240
页数:8
相关论文
共 50 条
  • [1] NEAR-INFRARED SPECTROSCOPY (NIRS) FOR APPLICATION IN UROLOGY
    Te, Alexis E.
    Chung, Doreen E.
    Lee, Richard I.
    Kaplan, Steven A.
    JOURNAL OF UROLOGY, 2009, 181 (04): : 601 - 602
  • [2] FUNCTIONAL NEAR-INFRARED SPECTROSCOPY (fNIRS): DEVELOPMENT AND APPLICATIONS IN NEUROSCIENCE
    Cinciute, Sigita
    Daktariunas, Algis
    Ruksenas, Osvaldas
    MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 75 - 78
  • [3] Pharmaceutical Applications of Near-Infrared Spectroscopy
    Muselik, Jan
    CHEMICKE LISTY, 2012, 106 (01): : 10 - 15
  • [4] Entomological applications of near-infrared spectroscopy
    Throne, JE
    Dowell, FE
    Perez-Mendoza, J
    Baker, JE
    ADVANCES IN STORED PRODUCT PROTECTION, 2003, : 131 - 134
  • [5] Near-infrared spectroscopy: Applications in neonates
    Sood, Beena G.
    McLaughlin, Kathleen
    Cortez, Josef
    SEMINARS IN FETAL & NEONATAL MEDICINE, 2015, 20 (03): : 164 - 172
  • [6] ANALYTICAL APPLICATIONS OF NEAR-INFRARED SPECTROSCOPY
    CIURCZAK, EW
    CHEMTECH, 1992, 22 (06) : 374 - 380
  • [7] Near-infrared spectroscopy for dermatological applications
    McIntosh, LM
    Jackson, M
    Mantsch, HH
    Mansfield, JR
    Crowson, AN
    Toole, JWP
    VIBRATIONAL SPECTROSCOPY, 2002, 28 (01) : 53 - 58
  • [8] Near-infrared spectroscopy - Clinical applications
    Simonson, SG
    Piantadosi, CA
    CRITICAL CARE CLINICS, 1996, 12 (04) : 1019 - &
  • [9] Near-infrared spectroscopy: Theory and applications
    Wahr, JA
    Tremper, KK
    Samra, S
    Delpy, DT
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1996, 10 (03) : 406 - 418
  • [10] Development of Portable Plant Components Measurement Instrument Based on Near-infrared Spectroscopy
    Ma, Hao
    Ji, Haiyan
    PROCEEDINGS OF THE 10TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA 2012), 2012, : 4163 - 4167