In this paper we describe the application of laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) coupling to particle analysis, i.e., the determination of the isotopic composition of micrometric uranium particles. The performances of this analysis technique are compared with those of the two reference particle analysis techniques: secondary ion mass spectrometry (SIMS) and fission track-thermo-ionization mass spectrometry (FT-TIMS), based on the measurement of the isotopic ratios of U-235/U-238 in particles present in an inter-comparison particulate sample. The agreement of the results obtained using LA-ICP-MS with target values and with the results obtained using FT-TIMS and SIMS was good. Accuracy was equivalent to that of the other two techniques (+/- 3 % deviation). However, relative experimental uncertainties present with LA-ICP-MS (7 %) were higher than those present with FT-TIMS (4.5 %) and SIMS (3 %). Furthermore, measurement yield of LA-ICP-MS coupling was close to that obtained with the same quadrupole ICP-MS for the measurement of a liquid sample (similar to 10(-4)), but lower than that obtained with FT-TIMS and SIMS, respectively, by a factor of 10 and 20, although the particles analyzed using LA-ICP-MS were most likely smaller (diameter similar to 0.6 mu m, containing 4-7 fg of U-235). Nevertheless, thanks to the brevity of the signals obtained, the detection capacity for low isotopic concentrations by LA-ICP-MS coupling is equivalent to that of FT-TIMS, although it remains well below that of SIMS (x15). However, with more sensitive double focusing ICP-MS, performances equivalent to those achieved using SIMS could be obtained.
引用
收藏
页码:609 / 616
页数:8
相关论文
共 14 条
[1]  
Aregbe Y, 2011, ESARDA B, V46, P136
[2]   Determining the isotopic compositions of uranium and fission products in radioactive environmental microsamples using laser ablation ICP-MS with multiple ion counters [J].
Boulyga, Sergei F. ;
Prohaska, Thomas .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (02) :531-539
[3]   Particle isolation for analysis of uranium minor isotopes in individual particles by secondary ion mass spectrometry [J].
Esaka, F. ;
Esaka, K. T. ;
Lee, C. G. ;
Magara, M. ;
Sakurai, S. ;
Usuda, S. ;
Watanabe, K. .
TALANTA, 2007, 71 (03) :1011-1015
[4]   Efficient isotope ratio analysis of uranium particles in swipe samples by total-reflection X-ray fluorescence spectrometry and secondary ion mass spectrometry [J].
Esaka, F ;
Watanabe, K ;
Fukuyama, H ;
Onodera, T ;
Esaka, KT ;
Magara, M ;
Sakurai, S ;
Usuda, S .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2004, 41 (11) :1027-1032
[5]   Comparison of ICP-MS and SIMS techniques for determining uranium isotope ratios in individual particles [J].
Esaka, F. ;
Magara, M. ;
Lee, C. G. ;
Sakurai, S. ;
Usuda, S. ;
Shinohara, N. .
TALANTA, 2009, 78 (01) :290-294
[6]   Development in fission track-thermal ionization mass spectrometry for particle analysis of safeguards environmental samples [J].
Lee, C. G. ;
Iguchi, K. ;
Inagawa, J. ;
Suzuki, D. ;
Esaka, F. ;
Magara, M. ;
Sakurai, S. ;
Watanabe, K. ;
Usuda, S. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 272 (02) :299-302
[7]   Evaluation of a new generation quadrupole-based ICP-MS for uranium isotopic measurements in environmental samples [J].
Pointurier, F. ;
Hubert, A. ;
Baglan, N. ;
Hemet, P. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (02) :505-511
[8]   Application of Nanosecond-UV Laser Ablation-Inductively Coupled Plasma Mass Spectrometry for the Isotopic Analysis of Single Submicrometer-Size Uranium Particles [J].
Pointurier, Fabien ;
Pottin, Anne-Claire ;
Hubert, Amelie .
ANALYTICAL CHEMISTRY, 2011, 83 (20) :7841-7848
[9]   Improved isotopic SIMS measurements of uranium particles for nuclear safeguard purposes [J].
Ranebo, Y. ;
Hedberg, P. M. L. ;
Whitehouse, M. J. ;
Ingeneri, K. ;
Littmann, S. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (03) :277-287
[10]   Study on analysis of isotopic ratio of uranium-bearing particle in swipe samples by FT-TIMS [J].
Shen, Yan ;
Zhao, Yonggang ;
Guo, Shi-Lun ;
Cui, Jianyong ;
Liu, Yuang ;
Li, Jinghuai ;
Xu, Jun ;
Zhang, Huizhen .
RADIATION MEASUREMENTS, 2008, 43 :S299-S302