An efficient cardiac signal enhancement using time-frequency realization of leaky adaptive noise cancelers for remote health monitoring systems

被引:25
作者
Rahman, Muhammad Zia Ur [1 ]
Karthik, G. V. S. [2 ]
Fathima, S. Y. [3 ]
Lay-Ekuakille, A. [4 ]
机构
[1] KL Univ, Dept Elect & Commun, Vaddeswaram 522002, AP, India
[2] Coimbatore Inst Technol, Dept Elect & Elect Engn, Coimbatore 641014, Tamil Nadu, India
[3] Vasireddy Venkatadri Inst Technol, Dept Elect & Commun Engn, Nambur 522508, India
[4] Univ Salento, Dept Innovating Engn, Salento, Italy
关键词
Artifacts; Biomedical signal processing; Biotelemetry; Block LMS algorithm; ECG; Leaky factor; Noise cancelation; DETERMINISTIC REFERENCE INPUTS; LMS ALGORITHM; FILTERS;
D O I
10.1016/j.measurement.2013.07.009
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Nowadays telecardiology is an important tool in cardiac diagnosis from a remote location. During Electrocardiogram (ECG) or Cardiac Signal acquisition several artifacts strongly affect the ST segment, degrade the signal quality, frequency resolution, produce large amplitude signals in ECG that can resemble PQRST waveforms and mask the tiny features that are important for clinical monitoring and diagnosis. So the extraction of high-resolution cardiac signals from recordings contaminated with artifacts is an important issue to investigate. In this paper, various novel block based time-frequency domain adaptive filter structures for cardiac signal enhancement are presented. These filters estimate the deterministic components of the cardiac signal and remove the noise component. The Block Leaky Least Mean Square (BLLMS) algorithm, being the solution of the steepest descent strategy for minimizing the mean squared error in a complete signal occurrence, is shown to be steady-state unbiased and with a lower variance than the LMS algorithm. To improve the filtering capability some variants of BLLMS, Block Normalized LLMS (BNLLMS) and Block Error Normalized LLMS (BENLLMS) algorithms are implemented in both time domain (TD) and frequency domains (FD). Finally, we have applied these algorithms on real cardiac signals obtained from the MIT-BIH data base and compared their performance with the conventional LLMS algorithm. The results show that the performance of the block based algorithms is superior to the LLMS counterparts in terms of signal to noise ratio improvement (SNRI), excess mean square error (EMSE) and misadjustment (M). Among all the algorithms FDBENLLMS achieves higher SNRI than other techniques. These values are 25.8713 dB, 20.1548 dB, 21.6718 dB and 20.7131 dBs for power line interference (PLI), baseline wander (BW), muscle artifacts (MA) and electrode motion artifacts (EM) removal. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3815 / 3835
页数:21
相关论文
共 27 条
[1]   Clinical Assessment of Wireless ECG Transmission in Real-Time Cardiac Telemonitoring [J].
Alesanco, Alvaro ;
Garcia, Jose .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (05) :1144-1152
[2]  
[Anonymous], 1230 IEEE
[3]  
[Anonymous], BIOMEDICAL SIGNAL PR
[4]  
[Anonymous], ADV BIOSIGNAL PROCES
[5]  
[Anonymous], BOST BETH ISR HOSP M
[6]   NORMALIZED DATA NONLINEARITIES FOR LMS ADAPTATION [J].
DOUGLAS, SC ;
MENG, THY .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1994, 42 (06) :1352-1365
[7]   A Fast Lane Approach to LMS prediction of respiratory motion signals [J].
Ernst, Floris ;
Schlaefer, Alexander ;
Dieterich, Sonja ;
Schweikard, Achim .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2008, 3 (04) :291-299
[8]   Analysis of the frequency-domain block LMS algorithm [J].
Farhang-Boroujeny, B ;
Chan, KS .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2000, 48 (08) :2332-2342
[9]  
FarhangBoroujeny B., 1998, Adaptive Filters: Theory and Applications, V3rd ed.
[10]   Comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG [J].
Hamilton, PS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (01) :105-109