Determination of dexamethasone by flow-injection chemiluminescence method using capped CdS quantum dots

被引:9
作者
Khataee, Alireza [1 ]
Hasanzadeh, Aliyeh [1 ]
Lotfi, Roya [1 ]
Pourata, Rahmatollah [2 ]
Joo, Sang Woo [3 ]
机构
[1] Univ Tabriz, Dept Appl Chem, Res Lab Adv Water & Wastewater Treatment Proc, Fac Chem, Tabriz 5166616471, Iran
[2] Univ Zanjan, Dept Chem, Fac Sci, Zanjan 4537138791, Iran
[3] Yeungnam Univ, Sch Mech Engn, Kyongsan 712749, South Korea
关键词
CdS quantum dots; Chemiluminescence; Dexamethasone; Flow injection; Nanocatalyst; ACIDIC POTASSIUM-PERMANGANATE; ENHANCED CHEMILUMINESCENCE; CUO NANOSHEETS; LIQUID-CHROMATOGRAPHY; L-CYSTEINE; SYSTEM; CDTE; WATER; PHARMACEUTICALS; ASSAY;
D O I
10.1016/j.saa.2015.05.047
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
L-Cysteine capped CdS quantum dots (QDs) were synthesized through a facile hydrothermal method and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), photoluminescence (PL) and UV-Vis spectroscopy. The light emitted from KMnO4-L-cysteine capped CdS QDs reaction in acidic medium was applied as a simple and sensitive chemiluminescence (CL) system for determination of dexamethasone. The CL intensity of KMnO4-L-cysteine capped CdS QDs CL system was remarkably enhanced in the presence of dexamethasone. Under optimum experimental conditions, the enhanced CL intensity was related to dexamethasone concentration in the range of 0.004-25.0 mg L-1, with the detection limit (3 sigma) of 0.0013 mg L-1. The analytical applicability of the proposed CL system was assessed by determining dexamethasone in spiked environmental water samples and pharmaceutical formulation. The analytical performances of proposed flow-injection CL method for the determination of dexamethasone were compared with those obtained by corona discharge ionization ion mobility spectrometry (CD-IMS) method. The proposed CL system exhibits a higher sensitivity and precision than the CD-IMS method for the determination of dexamethasone. (c) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 71
页数:9
相关论文
共 40 条
[1]   The characteristic red chemiluminescence from reactions with acidic potassium permanganate: further spectroscopic evidence for a manganese(II) emitter [J].
Adcock, Jacqui L. ;
Francis, Paul S. ;
Smith, Trevor A. ;
Barnett, Neil W. .
ANALYST, 2008, 133 (01) :49-51
[2]   Advances in the use of acidic potassium permanganate as a chemiluminescence reagent: A review [J].
Adcock, Jacqui L. ;
Barnett, Neil W. ;
Barrow, Colin J. ;
Francis, Paul S. .
ANALYTICA CHIMICA ACTA, 2014, 807 :9-28
[3]   Quantum dots-enhanced chemiluminescence: Mechanism and application [J].
Chen, Hui ;
Lin, Ling ;
Li, Haifang ;
Lin, Jin-Ming .
COORDINATION CHEMISTRY REVIEWS, 2014, 263 :86-100
[4]   Determination of L-ascorbic acid in human serum by chemiluminescence based on hydrogen peroxide-sodium hydrogen carbonate-CdSe/CdS quantum dots system [J].
Chen, Hui ;
Li, Ruibo ;
Lin, Ling ;
Guo, Guangsheng ;
Lin, Jin-Ming .
TALANTA, 2010, 81 (4-5) :1688-1696
[5]   Enhanced permanganate chemiluminescence [J].
Francis, Paul S. ;
Hindson, Christopher M. ;
Terry, Jessica M. ;
Smith, Zoe M. ;
Slezak, Teo ;
Adcock, Jacqui L. ;
Fox, Bronwyn L. ;
Barnett, Neil W. .
ANALYST, 2011, 136 (01) :64-66
[6]   VALIDATION OF A SIMPLE AND RAPID UV SPECTROPHOTOMETRIC METHOD FOR DEXAMETHASONE ASSAY IN TABLETS [J].
Friedrich, Rossana Barcellos ;
Ravanello, Aline ;
Cichota, Luiz Carlos ;
Bueno Rolim, Clarice Madalena ;
Ruver Beck, Ruy Carlos .
QUIMICA NOVA, 2009, 32 (04) :1052-1054
[7]   Application of quantum dots as analytical tools in automated chemical analysis: A review [J].
Frigerio, Christian ;
Ribeiro, David S. M. ;
Rodrigues, S. Sofia M. ;
Abreu, Vera L. R. G. ;
Barbosa, Joao A. C. ;
Prior, Joao A. V. ;
Marques, Karine L. ;
Santos, Joao L. M. .
ANALYTICA CHIMICA ACTA, 2012, 735 :9-22
[8]   Occurrence of pharmaceuticals in a water supply system and related human health risk assessment [J].
Gaffney, Vanessa de Jesus ;
Almeida, Cristina M. M. ;
Rodrigues, Alexandre ;
Ferreira, Elisabete ;
Benoliel, Maria Joao ;
Cardoso, Vitor Vale .
WATER RESEARCH, 2015, 72 :199-208
[9]   Simultaneous determination of dexamethasone, dexamethasone 21-acetate, and paclitaxel in a simulated biological matrix by RP-HPLC: Assay development and validation [J].
Goyal, Navin ;
El Achchabi, Amin ;
Goldberg, Eugene ;
Hochhaus, Guenther .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (10) :1478-1491
[10]   Fullerene-C60-modified edge plane pyrolytic graphite electrode for the determination of dexamethasone in pharmaceutical formulations and human biological fluids [J].
Goyal, Rajendra N. ;
Gupta, Vinod K. ;
Chatterjee, Sanghamitra .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (06) :1649-1654