Bell's dynamic interaction on a reinforced concrete bell tower

被引:10
作者
Ivorra, Salvador [1 ]
Foti, Dora [2 ]
Gallo, Valentina [2 ]
Vacca, Vitantonio [2 ]
Bru, David [1 ]
机构
[1] Univ Alicante, Dept Civil Engn, Apartado 99, San Vicente Del Raspeig 03080, Spain
[2] Polytech Univ Bari, Dept Civil Engn Sci & Architecture, Via Orabona 4, I-70125 Bari, Italy
关键词
Dynamic loads; Bell forces; OMA; Dynamic monitoring; Historical construction; BEHAVIOR;
D O I
10.1016/j.engstruct.2019.01.071
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present study shows a cheap and simple methodology to evaluate the dynamic behavior of a reinforced concrete bell tower built in 1974 made of concrete structural elements and brick masonry walls. The bell swinging vibrations on the tower are evident and they can be visually observed even without the use of any equipment. In this case a possible interaction between the bells' swinging and the tower vibration has been dynamically identified by the methodology here proposed. An experimental campaign was carried out on the bell tower to record the environmental vibrations and the accelerations induced by the movement of the bells during their swinging. In order to develop the methodology here proposed, the main characteristics of the bells have been measured and the time history force generated by each bell during the swing has been evaluated. A numerical model of the tower has been developed and calibrated by the Operational Modal Analysis technique. The model has then been validated utilizing the acceleration time-histories recorded under kilted excitations. Dynamic analyses have been carried out on the bell tower and the dynamic amplification factor (DAF) has been determined. From the results it is noticed that the bell tower does not comply with its maximum capacity due to the dynamic interaction with the bells swinging as evidenced by the presence of cracks on the facades of the tower. This paper highlights the dynamic problems that bells can cause to slender bell towers and proposes a simple and cheap solution.
引用
收藏
页码:965 / 975
页数:11
相关论文
共 25 条
[11]   Structural damage evaluation of industrial masonry chimneys [J].
Bru, David ;
Reynau, Ricardo ;
Javier Baeza, F. ;
Ivorra, Salvador .
MATERIALS AND STRUCTURES, 2018, 51 (01)
[12]  
Cannito G, 2017, A MARENA 1950 1978 B
[13]   Structural safety assessment of geometrically complex masonry vaults by non-linear analysis. The Chapel of the Wurzburg Residence (Germany) [J].
Compan, Victor ;
Pachon, Pablo ;
Camara, Margarita ;
Lourenco, Paulo B. ;
Saez, Andres .
ENGINEERING STRUCTURES, 2017, 140 :1-13
[14]  
Computers Structures Inc, 2014, SAP2000 V14 SOFTWARE
[15]  
Diaferio M., 2015, 6 INT OP MOD AN C IO
[16]   Prediction of the fundamental frequencies and modal shapes of historic masonry towers by empirical equations based on experimental data [J].
Diaferio, Mariella ;
Foti, Dora ;
Potenza, Francesco .
ENGINEERING STRUCTURES, 2018, 156 :433-442
[17]  
European Commitee for Standardization, 2004, EUR 8 DES STRUCT E 1, V1
[18]  
Foti Dora, 2015, Key Engineering Materials, V628, P168, DOI 10.4028/www.scientific.net/KEM.628.168
[19]   Dynamic forces produced by swinging bells [J].
Ivorra, S ;
Palomo, MJ ;
Verdú, G ;
Zasso, A .
MECCANICA, 2006, 41 (01) :47-62
[20]   Dynamic behaviour of a belfry caused by the swinging bells [J].
Ivorra, S ;
Palomo, MJ ;
Verdú, G .