Crohn disease with endoscopic correlation: Single-shot fast spin-echo and gadolinium-enhanced fat-suppressed spoiled gradient-echo MR imaging

被引:133
|
作者
Low, RN
Sebrechts, CP
Politoske, DA
Bennett, MT
Flores, S
Snyder, RJ
Pressman, JH
机构
[1] Sharp Mem Hosp & Rehabil Ctr, Sharp & Childrens MRI Ctr, San Diego, CA 92123 USA
[2] Sharp Mem Hosp & Rehabil Ctr, Dept Radiol, San Diego, CA 92123 USA
[3] Sharp Mem Hosp & Rehabil Ctr, Dept Gastroenterol, San Diego, CA 92123 USA
关键词
Crohn disease; magnetic resonance (MR); comparative studies;
D O I
10.1148/radiol.2223010811
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare T2-weighted breath-hold single-shot fast spin-echo (SE) and gadolinium-enhanced spoiled gradient-echo (GRE) MR imaging with contrast material administered orally and rectally for evaluating patients with Crohn disease. MATERIALS AND METHODS: Twenty-eight patients with Crohn disease received 2% barium sulfate and water enema. The abdomen and pelvis were imaged with transverse and coronal single-shot fast SE and gadolinium-enhanced spoiled GRE MR imaging. Two radiologists reviewed the two types of images for bowel disease. The extent, severity, and conspicuity of the disease were determined Proof of bowel disease at MR imaging was compared with that. g g p at endoscopy, barium study, and surgery. Statistical analysis was per-formed with the McNemar test. RESULTS: Twenty-five of 28 patients had proven abnormal bowel segments. The per-patient sensitivity of gadolinium-enhanced spoiled GRE MR imaging for the two radiologists was 100% and 96% versus 60% and 60% (P < .05) with single-shot fast SE MR imaging, Gadolinium-enhanced spoiled GRE MR images depicted more segments (54 and 52 of 61 segments; sensitivity, 89% and 85%, respectively) of the diseased bowel than did single-shot fast SE MR images (31 and 32 of 61 segments; sensitivity, 51% and 52%, respectively; P < .001). Severity of Crohn disease was correctly depicted at gadolinium-enhanced spoiled GRE imaging in 93% of patients versus in 43% of patients at single-shot fast SE imaging. CONCLUSION: In patients with Crohn disease, gadolinium-enhanced fat-suppressed spoiled GRE MR imaging better depicted the extent and severity of intestinal disease compared with single-shot fast SE imaging. (C) RSNA, 2002.
引用
收藏
页码:652 / 660
页数:9
相关论文
共 50 条
  • [1] MR dynamic Gadolinium-enhanced fast multiplanar spoiled gradient-echo and spin-echo T1-weighted fat-suppressed techniques in diagnosis of pancreatic carcinoma
    Meng-Su Zeng
    Fu-Hua Yan
    Kang-Rong Zhou
    Zhu-Wan Chen
    Ji-Zhang Sun
    Cai-Zhong Chen
    Wei-Bing Shi From the Dapartment of Radiology
    Hepatobiliary&PancreaticDiseasesInternational, 2002, (02) : 294 - 298
  • [2] Gradient-echo versus fat-suppressed fast spin-echo MR imaging of rotator cuff tears
    Sahin-Akyar, G
    Miller, TT
    Staron, RB
    McCarthy, DM
    Feldman, F
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) : 223 - 227
  • [3] RENAL-CANCER STAGING - COMPARISON OF CONTRAST-ENHANCED CT AND GADOLINIUM-ENHANCED FAT-SUPPRESSED SPIN-ECHO AND GRADIENT-ECHO MR-IMAGING
    SEMELKA, RC
    SHOENUT, JP
    MAGRO, CM
    KROEKER, MA
    MACMAHON, R
    GREENBERG, HM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04): : 597 - 602
  • [4] Stomach diseases: MR evaluation using combined T2-weighted single-shot echo train spin-echo and gadolinium-enhanced spoiled gradient-echo sequences
    Marcos, HB
    Semelka, RC
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (06): : 950 - 960
  • [5] Comparison of fat-suppressed fast spin-echo protondensity and fat-suppressed three-dimensional spoiled gradient-echo MR imaging of normal and abnormal articular cartilage in the knee using an animal model
    Peh, WC
    Chan, JH
    Wong, JW
    Shek, TW
    RADIOLOGY, 1999, 213P : 374 - 374
  • [6] DYNAMIC GRADIENT-ECHO AND FAT-SUPPRESSED SPIN-ECHO CONTRAST-ENHANCED MRI OF THE BREAST
    KERSLAKE, RW
    CARLETON, PJ
    FOX, JN
    IMRIE, MJ
    COOK, AM
    READ, JR
    BOWSLEY, SJ
    BUCKLEY, DL
    HORSMAN, A
    CLINICAL RADIOLOGY, 1995, 50 (07) : 440 - 454
  • [7] Gradient echo versus fat-suppressed fast spin-echo imaging of rotator cuff pathology: Surgical correlation
    SahinAkyar, G
    Miller, TT
    Staron, RB
    McCarthy, DM
    Feldman, F
    RADIOLOGY, 1997, 205 : 1691 - 1691
  • [8] Detection of cartilage lesions with fat-suppressed three-dimensional spoiled gradient-echo MR imaging
    Brossmann, J
    Frank, L
    Resnick, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (03) : 910 - 911
  • [9] CARDIAC MASSES - SIGNAL INTENSITY FEATURES ON SPIN-ECHO, GRADIENT-ECHO, GADOLINIUM-ENHANCED SPIN-ECHO, AND TURBOFLASH IMAGES
    SEMELKA, RC
    SHOENUT, JP
    WILSON, ME
    PELLECH, AE
    PATTON, JN
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04): : 415 - 420
  • [10] FAT-SUPPRESSED MR OF THE ORBIT AND CAVERNOUS SINUS - COMPARISON OF FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO
    MUKHERJI, SK
    TART, RP
    FITZSIMMONS, J
    BELDEN, C
    MCGORRAY, S
    GUY, J
    MANCUSO, AA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (09) : 1707 - 1714