Preclinical Evaluation of MR Attenuation Correction Versus CT Attenuation Correction on a Sequential Whole-Body MR/PET Scanner

被引:28
作者
Bini, Jason [1 ,2 ]
Izquierdo-Garcia, David [1 ]
Mateo, Jesus [1 ,3 ]
Machac, Josef [4 ]
Narula, Jagat [5 ,6 ]
Fuster, Valentin [3 ,5 ,6 ]
Fayad, Zahi A. [1 ,5 ,6 ,7 ]
机构
[1] Mt Sinai Sch Med, Translat & Mol Imaging Inst, New York, NY 10029 USA
[2] CUNY, Dept Biomed Engn, New York, NY 10021 USA
[3] Ctr Nacl Invest Cardiovasc, Madrid, Spain
[4] Mt Sinai Sch Med, Dept Radiol, Div Nucl Med, New York, NY 10029 USA
[5] Mt Sinai Sch Med, Zena & Michael A Weiner Cardiovasc Inst, Dept Cardiol, New York, NY 10029 USA
[6] Mt Sinai Sch Med, Marie Josee & Henry R Kravis Ctr Cardiovasc Hlth, New York, NY 10029 USA
[7] Mt Sinai Sch Med, Dept Radiol, New York, NY 10029 USA
关键词
positron emission tomography; magnetic resonance imaging; molecular imaging; attenuation correction; quantification; POSITRON-EMISSION-TOMOGRAPHY; HYBRID PET/MRI SYSTEMS; PET; CLASSIFICATION; REGISTRATION; DESIGN;
D O I
10.1097/RLI.0b013e31827a49ba
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The application of attenuation correction for combined magnetic resonance/positron emission tomography (MR/PET) systems is still a major challenge for accurate quantitative PET. Computed tomographic attenuation correction (CTAC) is the current clinical standard for PET/computed tomographic (CT) scans. Magnetic resonance, unlike CT, has no direct information about photon attenuation but, rather, proton densities. On combined MR/PET scanners, MR-based attenuation correction (MRAC) consists of assigning empirical attenuation coefficients to MR signal intensities. The objective of the current study was to evaluate the MRAC implemented on the combined MR/PET scanner versus the CTAC with the same PET data in an animal model. Materials and Methods: Acquisition was performed using a clinically approved sequential MR/PET scanner (Philips Ingenuity TF). Computed tomographic and MR/PET images of 20 New Zealand White rabbits were retrospectively analyzed. The animals were positioned on a customized animal bed to avoid movement between the CT and MR/PET scanners. Positron emission tomographic images from both methods (MRAC and CTAC) were generated. Voxel-by-voxel and region-of-interest (ROI) analyses were performed to determine differences in standardized uptake values (SUV). Regions of interest were drawn on the coregistered CT images for the aorta, liver, kidney, spine, and soft tissue (muscle) and superimposed on the PET images. Results: The voxel-by-voxel comparison of PET showed excellent correlation between MRAC and CTAC SUV values (R = 0.99; P < 0.0001). The mean of the difference of SUVs between all respective MRAC and CTAC voxels was -0.94% (absolute difference [AD] +/- SD, -0.06 +/- 0.30), confirming slight underestimation of MRAC. The ROI-based comparison similarly showed that MRAC SUV values were underestimated compared with CTAC SUV values. The mean difference between MRAC and CTAC for all ROIs was 10.8% (AD, -0.08 +/- 0.06; R = 0.99; P < 0.0001) and -9.7% (AD, -0.15 +/- 0.12; R = 0.99; P < 0.0001) for the SUV mean (SUVmean) and the SUV maximum (SUVmax), respectively. The highest differences were found in the spine (SUVmean -26.1% [-0.11]) and areas close to large bones such as the back muscles (SUVmean, -16.8% [-0.04]). Conclusions: In this study, we have compared MRAC and CTAC methods for PET attenuation correction in an animal model. We have confirmed that the MRAC method implemented on a sequential MR/PET scanner underestimates PET values by less than 10% in most regions, except the areas containing or close to large bone structures such as the spine or the back muscles. Bone segmentation is therefore suggested to be included in the MR attenuation map to minimize the quantification error of MRAC methods compared with the clinical standard CTAC. Further clinical studies need to be carried out to validate the clinical use of MRAC.
引用
收藏
页码:313 / 322
页数:10
相关论文
共 50 条
  • [21] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Vontobel, Jan
    Liga, Riccardo
    Possner, Mathias
    Clerc, Olivier F.
    Mikulicic, Fran
    Veit-Haibach, Patrick
    ter Voert, Edwin E. G. W.
    Fuchs, Tobias A.
    Stehli, Julia
    Pazhenkottil, Aju P.
    Benz, Dominik C.
    Graeni, Christoph
    Gaemperli, Oliver
    Herzog, Bernhard
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (10) : 1574 - 1580
  • [22] MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction
    Jan Vontobel
    Riccardo Liga
    Mathias Possner
    Olivier F. Clerc
    Fran Mikulicic
    Patrick Veit-Haibach
    Edwin E. G. W. ter Voert
    Tobias A. Fuchs
    Julia Stehli
    Aju P. Pazhenkottil
    Dominik C. Benz
    Christoph Gräni
    Oliver Gaemperli
    Bernhard Herzog
    Ronny R. Buechel
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 1574 - 1580
  • [23] Quantitative carotid PET/MR imaging: clinical evaluation of MR-Attenuation correction versus CT-Attenuation correction in F-18-FDG PET/MR emission data and comparison to PET/CT
    Bini, Jason
    Robson, Philip M.
    Calcagno, Claudia
    Eldib, Mootaz
    Fayad, Zahi A.
    AMERICAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 5 (03): : 293 - 304
  • [24] The effect of limited MR field of view in MR/PET attenuation correction
    Delso, Gaspar
    Martinez-Moeller, Axel
    Bundschuh, Ralph A.
    Nekolla, Stephan G.
    Ziegler, Sibylle I.
    MEDICAL PHYSICS, 2010, 37 (06) : 2804 - 2812
  • [25] Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging
    Lee, Tzu C.
    Alessio, Adam M.
    Miyaoka, Robert M.
    Kinahan, Paul E.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 60 (01) : 25 - 39
  • [26] A review of PET attenuation correction methods for PET-MR
    Krokos, Georgios
    Mackewn, Jane
    Dunn, Joel
    Marsden, Paul
    EJNMMI PHYSICS, 2023, 10 (01)
  • [27] Evaluation of attenuation correction in cardiac PET using PET/MR
    Lau, Jeffrey M. C.
    Laforest, R.
    Sotoudeh, H.
    Nie, X.
    Sharma, S.
    McConathy, J.
    Novak, E.
    Priatna, A.
    Gropler, R. J.
    Woodard, P. K.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (03) : 839 - 846
  • [28] CT-Based Attenuation Correction on the FLEX Triumph Preclinical PET/CT Scanner
    Prasad, Rameshwar
    Ay, Mohammad R.
    Ratib, Osman
    Zaidi, Habib
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 66 - 75
  • [29] Evaluation of attenuation correction in cardiac PET using PET/MR
    Jeffrey M. C. Lau
    R. Laforest
    H. Sotoudeh
    X. Nie
    S. Sharma
    J. McConathy
    E. Novak
    A. Priatna
    R. J. Gropler
    P. K. Woodard
    Journal of Nuclear Cardiology, 2017, 24 : 839 - 846
  • [30] A comparison of CT- and MR-based attenuation correction in neurological PET
    John C. Dickson
    Celia O’Meara
    Anna Barnes
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1176 - 1189