Preclinical Evaluation of MR Attenuation Correction Versus CT Attenuation Correction on a Sequential Whole-Body MR/PET Scanner

被引:28
|
作者
Bini, Jason [1 ,2 ]
Izquierdo-Garcia, David [1 ]
Mateo, Jesus [1 ,3 ]
Machac, Josef [4 ]
Narula, Jagat [5 ,6 ]
Fuster, Valentin [3 ,5 ,6 ]
Fayad, Zahi A. [1 ,5 ,6 ,7 ]
机构
[1] Mt Sinai Sch Med, Translat & Mol Imaging Inst, New York, NY 10029 USA
[2] CUNY, Dept Biomed Engn, New York, NY 10021 USA
[3] Ctr Nacl Invest Cardiovasc, Madrid, Spain
[4] Mt Sinai Sch Med, Dept Radiol, Div Nucl Med, New York, NY 10029 USA
[5] Mt Sinai Sch Med, Zena & Michael A Weiner Cardiovasc Inst, Dept Cardiol, New York, NY 10029 USA
[6] Mt Sinai Sch Med, Marie Josee & Henry R Kravis Ctr Cardiovasc Hlth, New York, NY 10029 USA
[7] Mt Sinai Sch Med, Dept Radiol, New York, NY 10029 USA
关键词
positron emission tomography; magnetic resonance imaging; molecular imaging; attenuation correction; quantification; POSITRON-EMISSION-TOMOGRAPHY; HYBRID PET/MRI SYSTEMS; PET; CLASSIFICATION; REGISTRATION; DESIGN;
D O I
10.1097/RLI.0b013e31827a49ba
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The application of attenuation correction for combined magnetic resonance/positron emission tomography (MR/PET) systems is still a major challenge for accurate quantitative PET. Computed tomographic attenuation correction (CTAC) is the current clinical standard for PET/computed tomographic (CT) scans. Magnetic resonance, unlike CT, has no direct information about photon attenuation but, rather, proton densities. On combined MR/PET scanners, MR-based attenuation correction (MRAC) consists of assigning empirical attenuation coefficients to MR signal intensities. The objective of the current study was to evaluate the MRAC implemented on the combined MR/PET scanner versus the CTAC with the same PET data in an animal model. Materials and Methods: Acquisition was performed using a clinically approved sequential MR/PET scanner (Philips Ingenuity TF). Computed tomographic and MR/PET images of 20 New Zealand White rabbits were retrospectively analyzed. The animals were positioned on a customized animal bed to avoid movement between the CT and MR/PET scanners. Positron emission tomographic images from both methods (MRAC and CTAC) were generated. Voxel-by-voxel and region-of-interest (ROI) analyses were performed to determine differences in standardized uptake values (SUV). Regions of interest were drawn on the coregistered CT images for the aorta, liver, kidney, spine, and soft tissue (muscle) and superimposed on the PET images. Results: The voxel-by-voxel comparison of PET showed excellent correlation between MRAC and CTAC SUV values (R = 0.99; P < 0.0001). The mean of the difference of SUVs between all respective MRAC and CTAC voxels was -0.94% (absolute difference [AD] +/- SD, -0.06 +/- 0.30), confirming slight underestimation of MRAC. The ROI-based comparison similarly showed that MRAC SUV values were underestimated compared with CTAC SUV values. The mean difference between MRAC and CTAC for all ROIs was 10.8% (AD, -0.08 +/- 0.06; R = 0.99; P < 0.0001) and -9.7% (AD, -0.15 +/- 0.12; R = 0.99; P < 0.0001) for the SUV mean (SUVmean) and the SUV maximum (SUVmax), respectively. The highest differences were found in the spine (SUVmean -26.1% [-0.11]) and areas close to large bones such as the back muscles (SUVmean, -16.8% [-0.04]). Conclusions: In this study, we have compared MRAC and CTAC methods for PET attenuation correction in an animal model. We have confirmed that the MRAC method implemented on a sequential MR/PET scanner underestimates PET values by less than 10% in most regions, except the areas containing or close to large bone structures such as the spine or the back muscles. Bone segmentation is therefore suggested to be included in the MR attenuation map to minimize the quantification error of MRAC methods compared with the clinical standard CTAC. Further clinical studies need to be carried out to validate the clinical use of MRAC.
引用
收藏
页码:313 / 322
页数:10
相关论文
共 50 条
  • [1] MRI-guided attenuation correction in whole-body PET/MR: assessment of the effect of bone attenuation
    Akbarzadeh, A.
    Ay, M. R.
    Ahmadian, A.
    Alam, N. Riahi
    Zaidi, H.
    ANNALS OF NUCLEAR MEDICINE, 2013, 27 (02) : 152 - 162
  • [2] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    David Izquierdo-Garcia
    Stephen J. Sawiak
    Karin Knesaurek
    Jagat Narula
    Valentin Fuster
    Joseph Machac
    Zahi A. Fayad
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1574 - 1584
  • [3] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    Izquierdo-Garcia, David
    Sawiak, Stephen J.
    Knesaurek, Karin
    Narula, Jagat
    Fuster, Valentin
    Machac, Joseph
    Fayad, Zahi A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) : 1574 - 1584
  • [4] Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
    Schulz, V.
    Torres-Espallardo, I.
    Renisch, S.
    Hu, Z.
    Ojha, N.
    Boernert, P.
    Perkuhn, M.
    Niendorf, T.
    Schaefer, W. M.
    Brockmann, H.
    Krohn, T.
    Buhl, A.
    Guenther, R. W.
    Mottaghy, F. M.
    Krombach, G. A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (01) : 138 - 152
  • [5] Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
    V. Schulz
    I. Torres-Espallardo
    S. Renisch
    Z. Hu
    N. Ojha
    P. Börnert
    M. Perkuhn
    T. Niendorf
    W. M. Schäfer
    H. Brockmann
    T. Krohn
    A. Buhl
    R. W. Günther
    F. M. Mottaghy
    G. A. Krombach
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 138 - 152
  • [6] Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner
    Delso, G.
    Martinez-Moeller, A.
    Bundschuh, R. A.
    Ladebeck, R.
    Candidus, Y.
    Faul, D.
    Ziegler, S. I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15) : 4361 - 4374
  • [7] Impact of Attenuation Correction on Quantification Accuracy in Preclinical Whole-Body PET Images
    Wanek, Thomas
    Schoellbauer, Lara
    Filip, Thomas
    Mairinger, Severin
    Sauberer, Michael
    Blaickner, Matthias
    Kuntner, Claudia
    FRONTIERS IN PHYSICS, 2020, 8
  • [8] MRI-guided attenuation correction in whole-body PET/MR: assessment of the effect of bone attenuation
    A. Akbarzadeh
    M. R. Ay
    A. Ahmadian
    N. Riahi Alam
    H. Zaidi
    Annals of Nuclear Medicine, 2013, 27 : 152 - 162
  • [9] Whole-body PET/MRI: The effect of bone attenuation during MR-based attenuation correction in oncology imaging
    Aznar, M. C.
    Sersar, R.
    Saabye, J.
    Ladefoged, C. N.
    Andersen, F. L.
    Rasmussen, J. H.
    Lofgren, J.
    Beyer, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1177 - 1183
  • [10] Evaluation of improved attenuation correction in whole-body PET/MR on patients with bone metastasis using various radiotracers
    Grafe, Hong
    Lindemann, Maike E.
    Ruhlmann, Verena
    Oehmigen, Mark
    Hirmas, Nader
    Umutlu, Lale
    Herrmann, Ken
    Quick, Harald H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (10) : 2269 - 2279