Contrast-noise-ratio (CNR) analysis and optimisation of breast-specific gamma imaging (BSGI) acquisition protocols

被引:1
|
作者
Dieckens, Dennis [1 ,2 ]
Lavalaye, Jules [2 ]
Romijn, Leo [1 ,2 ]
Habraken, Jan [1 ,2 ]
机构
[1] St Antonius Hosp, Dept Med Phys, NL-3435 CM Nieuwegein, Netherlands
[2] St Antonius Hosp, Dept Nucl Med, NL-3435 CM Nieuwegein, Netherlands
来源
EJNMMI RESEARCH | 2013年 / 3卷 / 01期
关键词
Breast cancer; Scintimammography; Tc-99m-sestamibi; Breast-specific gamma imaging; Contrast-detail phantom; CNR analysis; PROOF-OF-CONCEPT; SCINTIGRAPHY; CAMERAS; CANCER;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundBreast cancer is one of the most prevalent forms of cancer in women. Breast-specific gamma imaging (BSGI) is a diagnostic imaging method that uses sestamibi-labelled Tc-99 and a dedicated gamma camera to localize malignant lesions in breast tissue. The aim of this study is to investigate if the current acquisition protocol for BSGI at our hospital is optimized for the detection of lesions in our patients.MethodsWe analyzed patient data and performed a phantom study with a Dilon 6800 gamma camera. The patient data were collected from a group of 13 patients (740 MBq Tc-99m-sestamibi, four views per patient were dynamically acquired with a frame duration of 30 s per frame and a total acquisition time of 8 min per view). Reduced-time static images were created, and contrast-to-noise ratios of identified hotspots were determined for different acquisition times. For the phantom study, we used a contrast detail phantom to investigate the contrast and resolution properties, within the range of relevant clinical acquisition parameters. The phantom was filled with a concentration of 80 MBq in 500 ml of water, and we dynamically acquired frames for a total acquisition time of 60 min using a general purpose (GP) collimator. To compare the GP collimator with the high-resolution collimator, a second acquisition was made for both collimators with a total acquisition time of 16 min.ResultsThe initial analysis of BSGI scans of the 13 patients showed that a dose reduction by a factor of 3 would not have reduced the number of observable hotspots in each of the acquired views. However, a subsequent systematic analysis of our protocol with a contrast-detail phantom showed that dose reduction results in a lower observability of hotspots, whereas increased doses resulted in a higher observability.ConclusionWe believe that the results of our phantom study are relevant for clinical practice and that further dose reduction cannot be recommended for the BSGI exams at our hospital and that an increase of the administered activity should be considered.
引用
收藏
页数:9
相关论文
共 16 条
  • [1] Contrast-noise-ratio (CNR) analysis and optimisation of breast-specific gamma imaging (BSGI) acquisition protocols
    Dickerscheid, Dennis
    Lavalaye, Jules
    Romijn, Leo
    Habraken, Jan
    EJNMMI RESEARCH, 2013, 3
  • [2] Contrast-noise-ratio (CNR) analysis and optimisation of breast-specific gamma imaging (BSGI) acquisition protocols
    Dennis Dieckens
    Jules Lavalaye
    Leo Romijn
    Jan Habraken
    EJNMMI Research, 3 (1)
  • [3] Effectiveness of Breast-Specific Gamma Imaging (BSGI) for Breast Cancer in Korea: A Comparative Study
    Lee, Anbok
    Chang, Jina
    Lim, Woosung
    Kim, Bom Sahn
    Lee, Jee Eun
    Cha, Eun Suk
    Moon, Byung-In
    BREAST JOURNAL, 2012, 18 (05) : 453 - 458
  • [4] Breast-specific Gamma Imaging (BSGI) as a Complementary Imaging Tool for BI-RADS 0 and 4a Lesions on Mammography or Ultrasonography
    Ryu, Rae Rim
    Kim, Young Joong
    Seo, Jae Young
    Kim, Keum Won
    Kim, Jin Suk
    IRANIAN JOURNAL OF RADIOLOGY, 2022, 19 (02)
  • [5] Complementary Role of Semiquantitative Analysis of Breast-Specific Gamma Imaging in the Diagnosis of Breast Cancer
    Park, Kyung Sik
    Chung, Hyun Woo
    Yoo, Young Bum
    Yang, Jung-Hyun
    Choi, Nami
    So, Young
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (03) : 690 - 695
  • [6] Diagnostic Performance of Breast-Specific Gamma Imaging (BSGI) for Breast Cancer: Usefulness of Dual-Phase Imaging with 99mTc-sestamibi
    Park J.S.
    Lee A.Y.
    Jung K.P.
    Choi S.J.
    Lee S.M.
    kyun Bae S.
    Nuclear Medicine and Molecular Imaging, 2013, 47 (1) : 18 - 26
  • [7] Clinical usefulness of breast-specific gamma imaging as an adjunct modality to mammography for diagnosis of breast cancer: a systemic review and meta-analysis
    Sun, Yu
    Wei, Wei
    Yang, Hua-Wei
    Liu, Jian-Lun
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (03) : 450 - 463
  • [8] Usefulness of feature analysis of breast-specific gamma imaging for predicting malignancy
    Choi, Eun Kyoung
    Im, Jooyeon Jamie
    Park, Chang Suk
    Chung, Yong-An
    Kim, Kijun
    Oh, Jin Kyoung
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5195 - 5202
  • [9] Correlations between Tumor to Background Ratio on Breast-Specific Gamma Imaging and Prognostic Factors in Breast Cancer
    Lee, Soo Jin
    Choi, Yun Young
    Kim, Chanwoo
    Chung, Min Sung
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2017, 32 (06) : 1031 - 1037
  • [10] Breast-specific gamma imaging versus ultrasound and mammography for breast cancer diagnosis: A meta-analysis
    Zhang, Y.
    Zhu, D.
    Feng, R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2024, 22 (01):