Ultrasensitive determination of receptor tyrosine kinase with a label-free electrochemical immunosensor using graphene quantum dots-modified screen-printed electrodes

被引:56
|
作者
Mollarasouli, Fariba [1 ,2 ]
Serafin, Veronica [2 ]
Campuzano, Susana [2 ]
Yanez-Sedeno, Paloma [2 ]
Pingarron, Jose M. [2 ,3 ]
Asadpour-Zeynali, Karim [1 ]
机构
[1] Univ Tabriz, Fac Chem, Dept Analyt Chem, Tabriz 5166616471, Iran
[2] Univ Complutense Madrid, Fac Ciencias Quim, Dept Quim Analit, E-28040 Madrid, Spain
[3] IMDEA Nanosci, Ciudad Univ Cantoblanco, Madrid 28049, Spain
关键词
Graphene quantum dots (GQDs); Label-free; Electrochemical immunosensor; AXL; Serum; Screen-printed carbon electrode (SPCE); SENSITIVE DETECTION; PARATHION; SENSOR; AMINE;
D O I
10.1016/j.aca.2018.01.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new label-free electrochemical immunosensor is constructed for the selective and sensitive determination of the clinically relevant biomarker receptor tyrosine kinase (AXL) in human serum. The disposable immunosensing platform is prepared by immobilization of the specific anti-AXL antibody onto amine functionalized graphene quantum dots (fGQDs)-modified screen-printed carbon electrodes (SPCEs). The affinity reactions were monitored by measuring the decrease in the differential pulse voltammetric (DPV) response of the redox probe Fe(CNI)(6)(3-/4-). All the experimental variables involved in the preparation of the modified electrodes and in the immunosensor performance were optimized. The as prepared immunosensor exhibits an improved analytical performance with respect to other electrochemical immunosensors reported so far, with a wider range of linearity and a lower detection limit, 0.5 pg mL(-1), which is more than one hundred thousand times lower than the established cut-off value for heart failure (HF) diagnosis in serum (71 ng mL(-1)). The developed immunosensor was successfully applied to the determination of the endogenous content of AXL in serum of HF patients without any matrix effect observed after just a sample dilution. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 50 条
  • [1] Impedimetric Label-Free Immunosensor on Disposable Modified Screen-Printed Electrodes for Ochratoxin A
    Malvano, Francesca
    Albanese, Donatella
    Crescitelli, Alessio
    Pilloton, Roberto
    Esposito, Emanuela
    BIOSENSORS-BASEL, 2016, 6 (03):
  • [2] Label-free electrochemical impedance immunosensor based on modified screen-printed gold electrodes for the diagnosis of canine visceral leishmaniasis
    Cordeiro, Tais A. R.
    Goncalves, Marcus V. C.
    Franco, Diego L.
    Reis, Alexandre B.
    Martins, Helen R.
    Ferreira, Lucas F.
    TALANTA, 2019, 195 : 327 - 332
  • [3] Voltammetric determination of dopamine in the presence of tyrosine using graphite screen-printed electrode modified with graphene quantum dots
    Beitollahi, Hadi
    Dourandish, Zahra
    Ganjali, Mohammad Reza
    Shakeri, Shahryar
    IONICS, 2018, 24 (12) : 4023 - 4031
  • [4] Voltammetric determination of dopamine in the presence of tyrosine using graphite screen-printed electrode modified with graphene quantum dots
    Hadi Beitollahi
    Zahra Dourandish
    Mohammad Reza Ganjali
    Shahryar Shakeri
    Ionics, 2018, 24 : 4023 - 4031
  • [5] Electrochemical determination of propranolol by using modified screen-printed electrodes
    Mohammadi, Sayed Zia
    Tajik, Somayeh
    Beitollahi, Hadi
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2020, 27 (01) : 73 - 78
  • [6] A label-free electrochemical immunosensor for the detection of cardiac marker using graphene quantum dots (GQDs)
    Tuteja, Satish K.
    Chen, Rui
    Kukkar, Manil
    Song, Chung Kil
    Mutreja, Ruchi
    Singh, Suman
    Paul, Ashok K.
    Lee, Haiwon
    Kim, Ki-Hyun
    Deep, Akash
    Suri, C. Raman
    BIOSENSORS & BIOELECTRONICS, 2016, 86 : 548 - 556
  • [7] Electrochemical Sensing of Isoproterenol using Graphite Screen-printed Electrode Modified with Graphene Quantum Dots
    Dourandish, Zahra
    Beitollahi, Hadi
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (02): : 192 - 202
  • [8] Graphene Quantum Dots Modified Screen-printed Electrodes as Electroanalytical Sensing Platform for Diethylstilbestrol
    Gevaerd, Ava
    Banks, Craig E.
    Bergamini, Marcio F.
    Marcolino-Junior, Luiz Humberto
    ELECTROANALYSIS, 2019, 31 (05) : 838 - 843
  • [9] A label-free impedimetric immunosensor for zearalenone based on CS-CNT-Pd nanocomposite modified screen-printed disposable electrodes
    Kumar, V. Sunil
    Kummari, Shekher
    Catanante, Gaelle
    Gobi, K. Vengatajalabathy
    Marty, Jean Louis
    Goud, K. Yugender
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 377
  • [10] A label-free Electrochemical Immunosensor Based on Polythionine-nanogold Nanocomposite for Detection of Trypsin Using screen-printed Electrode
    Hu, Jianxiong
    Li, Quwen
    Chen, Jianhui
    Chen, Shijun
    Cai, Yangfang
    Zhao, Chengfei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):