X-ray phase-shifts-based method of volumetric breast density measurement

被引:11
|
作者
Wu, Xizeng [1 ]
Yan, Aimin [1 ]
Liu, Hong [2 ,3 ]
机构
[1] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35233 USA
[2] Univ Oklahoma, Ctr Bioengn, Norman, OK 73019 USA
[3] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK 73019 USA
关键词
X-ray phase contrast; phase retrieval; breast density; SYNCHROTRON-RADIATION; MAMMOGRAPHY; RETRIEVAL; IMAGES;
D O I
10.1118/1.4729838
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The high breast density is one of the biggest risk factors for breast cancer. Identifying patient having persistent high breast density is important for breast cancer screening and prevention. In this work the authors propose for the first time an x-ray phase-shifts-based method of breast density measurement. Methods: When x ray traverses the breast, x ray gets not only its intensity attenuated but also its phase shifted. Studying the x-ray phase-shifts generated by the breast tissues, we derived a general formula for determining the volumetric breast density from the breast phase map. The volumetric breast density is reconstructed by retrieving the breast phase map from just a single phase-sensitive projection of the breast, through the use of an innovative phase retrieval method based on the phase-attenuation duality. In order to numerically validate this phase-shifts-based method for measuring the volumetric breast density, the authors performed computer simulations with a digitally simulated anthropomorphic breast phantom. Results: Using the proposed phase-shifts-based method, we reconstructed the breast phantom's volumetric breast density, which differs from the phantom's intrinsic breast density by only 0.06%. In the presence of noises in the projection image, the reconstructed volumetric breast density differs from the phantom's intrinsic breast density by only 1.79% for a projection signal-to-noise-ratio (SNR) of 34. The error in reconstructed breast density is further reduced to 1.61% and 1.55% for SNR = 68 and SNR = 134, respectively, achieving good accuracies in the breast density determination. Conclusions: The authors proposed an x-ray phase-shifts-based method of measuring the volumetric breast density. The simulation results numerically validated the proposed method as a novel method of breast density measurement with good accuracies. 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4729838]
引用
收藏
页码:4239 / 4244
页数:6
相关论文
共 50 条
  • [41] Development of simulations for a mesh-based x-ray phase imaging system
    Hasan, Laila
    Pyakurel, Uttam
    Sun, Weiyuan
    MacDonald, Carolyn A.
    Petruccelli, Jonathan C.
    COMPUTATIONAL IMAGING V, 2020, 11396
  • [42] Charge density measurement in MgH2 by synchrotron X-ray diffraction
    Noritake, T
    Towata, S
    Aoki, M
    Seno, Y
    Hirose, Y
    Nishibori, E
    Takata, M
    Sakata, M
    JOURNAL OF ALLOYS AND COMPOUNDS, 2003, 356 : 84 - 86
  • [43] A phase sensitive x-ray breast tomosynthesis system: Preliminary patient images with cancer lesions
    Ghani, Muhammad U.
    Fajardo, Laurie L.
    Omoumi, Farid
    Yan, Aimin
    Jenkins, Peter
    Wong, Molly
    Li, Yuhua
    Peterson, Michael E.
    Callahan, Edward J.
    Hillis, Stephen L.
    Zheng, Bin
    Wu, Xizeng
    Liu, Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (21)
  • [44] Hard X-ray phase-contrast tomography of non-homogeneous specimens: grating interferometry versus propagation-based imaging
    Ruiz-Yaniz, Maite
    Zanette, Irene
    Sarapata, Adrian
    Birnbacher, Lorenz
    Marschner, Mathias
    Chabior, Michael
    Olbinado, Margie
    Pfeiffer, Franz
    Rack, Alexander
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1202 - 1209
  • [45] Fundamentals and Applications of Stress Measurement Method Using White X-ray
    Shibano J.-I.
    Zairyo/Journal of the Society of Materials Science, Japan, 2023, 72 (04) : 306 - 315
  • [46] Crystal-Based X-ray Interferometry and Its Application to Phase-Contrast X-ray Imaging, Zeff Imaging, and X-ray Thermography
    Yoneyama, Akio
    Takamatsu, Daiko
    Lwin, Thet-Thet
    Yamada, Shigehito
    Takakuwa, Tetsuya
    Hyodo, Kazuyuki
    Hirano, Keiichi
    Takeya, Satoshi
    APPLIED SCIENCES-BASEL, 2023, 13 (09):
  • [47] Image correction method without gain correction in grating-based X-ray phase-contrast imaging
    Zan, Guibin
    Hu, Renfang
    Wu, Zhao
    Wang, Qiuping
    Yun, Wenbing
    Wang, Ge
    SECOND SYMPOSIUM ON NOVEL TECHNOLOGY OF X-RAY IMAGING, 2019, 11068
  • [48] X-ray scatter correction method for dedicated breast computed tomography
    Sechopoulos, Ioannis
    MEDICAL PHYSICS, 2012, 39 (05) : 2896 - 2903
  • [49] In-Line Phase Contrast Mammography, Phase Contrast Digital Breast Tomosynthesis, and Phase Contrast Breast Computed Tomography With a Dedicated CT Scanner and a Microfocus X-Ray Tube: Experimental Phantom Study
    Mettivier, Giovanni
    di Franco, Francesca
    Sarno, Antonio
    Castriconi, Roberta
    Di Lillo, Francesca
    Bliznakova, Kristina
    Russo, Paolo
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (06) : 793 - 806
  • [50] Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography
    Brun, E.
    Grandl, S.
    Sztrokay-Gaul, A.
    Barbone, G.
    Mittone, A.
    Gasilov, S.
    Bravin, A.
    Coan, P.
    MEDICAL PHYSICS, 2014, 41 (11)