Small-animal tomography with a liquid-metal-jet x-ray source

被引:1
作者
Larsson, D. H. [1 ]
Lundstrom, U. [1 ]
Westermark, U. [2 ]
Takman, P. A. C. [1 ,3 ]
Burvall, A. [1 ]
Henriksson, M. Arsenian [2 ]
Hertz, H. M. [1 ]
机构
[1] Royal Inst Technol, Dept Appl Phys, Roslagstullsbacken 21, Stockholm, Sweden
[2] Karolinska Inst, Dept Microbiol Tumor & Cell Biol MTC, Stockholm, Sweden
[3] Excillum AB, Kista, Sweden
来源
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING | 2012年 / 8313卷
关键词
Small-animal imaging; liquid-metal-jet-anode; x-ray; tomography; mouse; PHASE-CONTRAST;
D O I
10.1117/12.910777
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray tomography of small animals is an important tool for medical research. For high-resolution x-ray imaging of few-cm-thick samples such as, e.g., mice, high-brightness x-ray sources with energies in the few-10-keV range are required. In this paper we perform the first small-animal imaging and tomography experiments using liquid-metal-jet-anode x-ray sources. This type of source shows promise to increase the brightness of microfocus x-ray systems, but present sources are typically optimized for an energy of 9 keV. Here we describe the details of a high-brightness 24-keV electron-impact laboratory microfocus x-ray source based on continuous operation of a heated liquid-In/Ga-jet anode. The source normally operates with 40 W of electron-beam power focused onto the metal jet, producing a 7x7 mu m(2) FWHM x-ray spot. The peak spectral brightness is 4x10(9) photons/(sxmm(2)xmrad(2)x0.1%BW) at the 24.2 keV In K-alpha line. We use the new In/Ga source and an existing Ga/In/Sn source for high-resolution imaging and tomography of mice.
引用
收藏
页数:7
相关论文
共 15 条
  • [1] [Anonymous], 1990, IMAGING SYSTEMS MED
  • [2] In vivo small-animal imaging using micro-CT and digital subtraction angiography
    Badea, C. T.
    Drangova, M.
    Holdsworth, D. W.
    Johnson, G. A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19) : R319 - R350
  • [3] Phase retrieval in X-ray phase-contrast imaging suitable for tomography
    Burvall, Anna
    Lundstrom, Ulf
    Takman, Per A. C.
    Larsson, Daniel H.
    Hertz, Hans M.
    [J]. OPTICS EXPRESS, 2011, 19 (11): : 10359 - 10376
  • [4] ELECTRON-BEAM MELTING IN MICROFOCUS X-RAY TUBES
    GRIDER, DE
    WRIGHT, A
    AUSBURN, PK
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1986, 19 (12) : 2281 - 2292
  • [5] Liquid-metal-jet anode X-ray tube
    Hemberg, O
    Otendal, M
    Hertz, HM
    [J]. OPTICAL ENGINEERING, 2004, 43 (07) : 1682 - 1688
  • [6] Liquid-metal-jet anode electron-impact x-ray source
    Hemberg, O
    Otendal, M
    Hertz, HM
    [J]. APPLIED PHYSICS LETTERS, 2003, 83 (07) : 1483 - 1485
  • [7] Hubbell J.H., 2011, Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients from 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest
  • [8] ATOMIC RADIATIVE AND RADIATIONLESS YIELDS FOR K-SHELLS AND L-SHELLS
    KRAUSE, MO
    [J]. JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1979, 8 (02) : 307 - 327
  • [9] A 24 keV liquid-metal-jet x-ray source for biomedical applications
    Larsson, D. H.
    Takman, P. A. C.
    Lundstrom, U.
    Burvall, A.
    Hertz, H. M.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (12)
  • [10] SOME KAPPA-X-RAY RELATIVE TRANSITION-PROBABILITIES FOR Z = 47, 49, 52, 55 AND 56
    MARTINS, MC
    MARQUES, MI
    PARENTE, F
    FERREIRA, JG
    [J]. JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1989, 22 (20) : 3167 - 3174