Dosimetric verification of RapidArc treatment delivery

被引:93
作者
Korreman, Stine [1 ]
Medin, Joakim [1 ]
Kjaer-Kristoffersen, Flemming [1 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Radiat Oncol, Finsen Ctr Sect 3994, DK-2100 Copenhagen O, Denmark
关键词
INTENSITY-MODULATED RADIOTHERAPY; DYNAMIC MULTILEAF COLLIMATION; ARC THERAPY; IMRT; TOMOTHERAPY; EXPERIENCE;
D O I
10.1080/02841860802287116
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. Recently, Varian Medical Systems have announced the introduction of a new treatment technique, in which dose is delivered over a single gantry rotation with variable MLC positions, dose rate and gantry speed. In February 2008, a preclinical installation of the RapidArc beam delivery approach was carried out on a Varian Clinac at Rigshospitalet in Copenhagen. The purpose of the installation was to perform measurements to verify the correctness of doses delivered with the RapidArc technique. In May 2008, the clinical release of the RapidArc application was installed at Rigshospitalet. Methods and materials. Nine treatment plans were generated in the Eclipse version 8.5 including the RapidArc optimizer for HN and prostate cases. The plans were delivered to the Scandidos Delta4 cylindrical diode array phantom. First, the measured dose distributions were compared with the calculated doses. All plans were then delivered several times to verify consistency of the delivery. Gamma analysis was used to verify the correspondence between dose distributions. The temporal resolution of the delivery was analysed by investigating the arc segments between control points separately. Results. Overall, good agreement was observed between measured and calculated doses in most cases with gamma values above 1 in 95% of measured points. The reproducibility of delivery was also very high. Gamma analysis between two consecutive runs of the same delivery plan generally showed gamma values above 1 in none of the measured points, and dose deviation less than 1%. Temporal analysis showed small discrepancies between doses delivered between control points (2 degrees of the rotation) in consecutive runs of a plan, however these were cancelled out in the accumulated dose. Conclusion. The delivery of RapidArc beam delivery has been verified to correspond well with calculated dose distributions for a number of different cases. The delivery was very reproducible, and was carried out with high stability of the accelerator performance.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 9 条
[1]   Commissioning of a commercially available system for intensity-modulated radiotherapy dose delivery with dynamic multileaf collimation [J].
Essers, M ;
de Langen, M ;
Dirkx, MLP ;
Heijmen, BJM .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (02) :215-224
[2]  
LING C, 2008, INT J RAD IN PRESS
[3]   Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode [J].
LoSasso, T ;
Chui, CS ;
Ling, CC .
MEDICAL PHYSICS, 2001, 28 (11) :2209-2219
[4]   Optimized intensity-modulated arc therapy for prostate cancer treatment [J].
Ma, LJ ;
Yu, CX ;
Earl, M ;
Holmes, T ;
Sarfaraz, M ;
Li, XA ;
Shepard, D ;
Amin, P ;
DiBiase, S ;
Suntharalingam, M ;
Mansfield, C .
INTERNATIONAL JOURNAL OF CANCER, 2001, 96 (06) :379-384
[5]   Tomotherapy [J].
Mackie, TR ;
Balog, J ;
Ruchala, K ;
Shepard, D ;
Aldridge, S ;
Fitchard, E ;
Reckwerdt, P ;
Olivera, G ;
McNutt, T ;
Mehta, M .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (01) :108-117
[6]   Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification [J].
McDermott, L. N. ;
Wendling, M. ;
van Asselen, B. ;
Stroom, J. ;
Sonke, J. -J. ;
van Herk, M. ;
Mijnheer, B. J. .
MEDICAL PHYSICS, 2006, 33 (10) :3921-3930
[7]   Volumetric modulated arc therapy: IMRT in a single gantry arc [J].
Otto, Karl .
MEDICAL PHYSICS, 2008, 35 (01) :310-317
[8]   Acceptance tests and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and the sliding window technique:: experience from five radiotherapy departments [J].
Van Esch, A ;
Bohsung, J ;
Sorvari, P ;
Tenhunen, M ;
Paiusco, M ;
Iori, M ;
Engström, P ;
Nyström, H ;
Huyskens, DP .
RADIOTHERAPY AND ONCOLOGY, 2002, 65 (01) :53-70
[9]   INTENSITY-MODULATED ARC THERAPY WITH DYNAMIC MULTILEAF COLLIMATION - AN ALTERNATIVE TO TOMOTHERAPY [J].
YU, CX .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (09) :1435-1449