Online Diagnosis and Localization of High-Resistance Connection in PMSM With Improved Fault Indicator

被引:39
作者
Zhang, Jianzhong [1 ]
Hang, Jun [1 ,2 ]
Ding, Shichuan [1 ,3 ]
Cheng, Ming [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
[2] Anhui Univ, Coll Elect Engn & Automat, Hefei 230601, Peoples R China
[3] Anhui Univ, Natl Engn Lab Energy Saving Motor & Control Tech, Hefei 230601, Peoples R China
基金
中国国家自然科学基金;
关键词
Fault diagnosis; frequency tracking algorithm; high-resistance connection (HRC); permanent magnet machine; wind energy; INDUCTION-MOTOR DRIVES; TURN FAULTS; MACHINES; UNBALANCE; SYSTEM;
D O I
10.1109/TPEL.2016.2587670
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a method for online diagnosis and localization of high-resistance connection (HRC) in permanent magnet synchronous machine (PMSM) with an improved fault indicator. In the proposed method, the amplitude and initial phase angle of zero-sequence voltage component are both analyzed. Based on the analysis, the fault indicator with angle difference is defined for fault diagnosis and localization. It is shown that not only the HRC can be detected, but also the fault severity can be assessed and the faulty phases can be identified in this method. The simulation and experiment are carried out to verify the theoretical analysis. Both the results show that the proposed method can be effectively applied for online detection and identification of the HRC in the PMSM.
引用
收藏
页码:3585 / 3594
页数:10
相关论文
共 28 条
[21]   Short-Circuit Detection by Means of Empirical Mode Decomposition and Wigner-Ville Distribution for PMSM Running Under Dynamic Condition [J].
Rosero, Javier A. ;
Romeral, Luis ;
Ortega, Juan A. ;
Rosero, Esteban .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (11) :4534-4547
[22]   Mixed resistive unbalance and winding inter-turn faults model of permanent magnet synchronous motors [J].
Urresty, Julio-Cesar ;
Riba, Jordi-Roger ;
Romeral, Luis ;
Antonio Ortega, Juan .
ELECTRICAL ENGINEERING, 2015, 97 (01) :75-85
[23]   Influence of the Stator Windings Configuration in the Currents and Zero-Sequence Voltage Harmonics in Permanent Magnet Synchronous Motors With Demagnetization Faults [J].
Urresty, Julio-Cesar ;
Riba, Jordi-Roger ;
Romeral, Luis .
IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (08) :4885-4893
[24]   Diagnosis of Interturn Faults in PMSMs Operating Under Nonstationary Conditions by Applying Order Tracking Filtering [J].
Urresty, Julio-Cesar ;
Riba, Jordi-Roger ;
Romeral, Luis .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (01) :507-515
[25]   Dynamic Permanent Magnet Flux Estimation of Permanent Magnet Synchronous Machines [J].
Xiao, Xi ;
Chen, Changming ;
Zhang, Meng .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) :1085-1088
[26]   Online Detection of High-Resistance Connections in the Incoming Electrical Circuit for Induction Motors [J].
Yun, Jangho ;
Cho, Jintae ;
Lee, Sang Bin ;
Yoo, Ji-Yoon .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (02) :694-702
[27]   Detection and Classification of Stator Turn Faults and High-Resistance Electrical Connections for Induction Machines [J].
Yun, Jangho ;
Lee, Kwanghwan ;
Lee, Kwang-Woon ;
Lee, Sang Bin ;
Yoo, Ji-Yoon .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (02) :666-675
[28]   Detection and Localization of Stator Resistance Dissymmetry Based on Multiple Reference Frame Controllers in Multiphase Induction Motor Drives [J].
Zarri, Luca ;
Mengoni, Michele ;
Gritli, Yasser ;
Tani, Angelo ;
Filippetti, Fiorenzo ;
Serra, Giovanni ;
Casadei, Domenico .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (08) :3506-3518