Attomole Antigen Detection Using Self-Electrochemiluminous Graphene Oxide-Capped Au@L012 Nanocomposite

被引:31
作者
Cui, Chen [1 ]
Chen, Ying [1 ]
Jiang, Dechen [1 ]
Zhu, Jun-Jie [1 ]
Chen, Hong-Yuan [1 ]
机构
[1] Nanjing Univ, Sch Chem & Chem Engn, State Key Lab Analyt Chem Life Sci, Nanjing 210093, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
ALKALINE AQUEOUS-SOLUTIONS; ELECTROGENERATED CHEMILUMINESCENCE; ENHANCED ELECTROCHEMILUMINESCENCE; GOLD NANOPARTICLES; QUANTUM DOTS; ULTRASENSITIVE DETECTION; LUMINOL; ELECTRODE; SIGNAL; ACID;
D O I
10.1021/acs.analchem.6b04305
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a self-electrochemiluminous graphene oxide capped Au@L012 nanocomposite was prepared as the label at carcinoembryonic (CEA) antibody to detect attomole CEA antigen. To maximize the luminescence intensity, L012 molecules (luminol analogue) were linked with poly(diallyldimethylammonium chloride) (PDDA) to form positive charged PDDA&L012 pairs, which were modified on negative charged Au@nafion nanoparticles to construct a Au@nafion@PDDA&L012 (Au@L012) complex. Graphene oxide with carboxyl groups was capped at Au@L012 complex through electrostatic interaction to serve as an effective matrix for the covalent attachment of CEA antibody. As compared with the traditional used Au nanoparticles modified with luminol, similar to 740-fold increase of self-luminescence was observed from this new complex so that CEA antigen as low as 0.5 amol at electrode surface was measurable in the absence of any coreactant. Moreover, the nanocomposite was attached with CEA antigen at MCF-7 cells allowing the detection of CEA antigen from 72 cells. The success in the detection of surface antigen at small population of cells suggested the self-electrochemiluminescence nanocomposite as the new and biosafe label for the ECL immunoassay, which might push the application of ECL for the cellular immunoanalysis.
引用
收藏
页码:2418 / 2423
页数:6
相关论文
共 40 条
[1]   Graphene Oxide-Based Supramolecular Hydrogels for Making Nanohybrid Systems with Au Nanoparticles [J].
Adhikari, Bimalendu ;
Biswas, Abbijit ;
Banerjee, Arindam .
LANGMUIR, 2012, 28 (02) :1460-1469
[2]   Ultrasensitive Nanoimmunosensor by coupling non-covalent functionalized graphene oxide platform and numerous ferritin labels on carbon nanotubes [J].
Akter, Rashida ;
Jeong, Bongjin ;
Choi, Jong-Soon ;
Rahman, Md Aminur .
BIOSENSORS & BIOELECTRONICS, 2016, 80 :123-130
[3]   An effective hydrothermal route for the synthesis of multiple PDDA-protected noble-metal nanostructures [J].
Chen, Hongjun ;
Wang, Yuling ;
Dong, Shaojun .
INORGANIC CHEMISTRY, 2007, 46 (25) :10587-10593
[4]   Gold nanoparticle-modified ITO electrode for electrogenerated chemilumineseence: Well-preserved transparency and highly enhanced activity [J].
Chen, Zuofeng ;
Zu, Yanbing .
LANGMUIR, 2007, 23 (23) :11387-11390
[5]   Design and Biosensing of Mg2+-Dependent DNAzyme-Triggered Ratiometric Electrochemiluminescence [J].
Cheng, Yan ;
Huang, Yin ;
Lei, Jianping ;
Zhang, Lei ;
Ju, Huangxian .
ANALYTICAL CHEMISTRY, 2014, 86 (10) :5158-5163
[6]   Electrochemical Immunosensors for Detection of Cancer Protein Biomarkers [J].
Chikkaveeraiah, Bhaskara V. ;
Bhirde, Ashwinkumar A. ;
Morgan, Nicole Y. ;
Eden, Henry S. ;
Chen, Xiaoyuan .
ACS NANO, 2012, 6 (08) :6546-6561
[7]   Multichannel electrochemiluminescence of luminol in neutral and alkaline aqueous solutions on a gold nanoparticle self-assembled electrode [J].
Cui, H ;
Xu, Y ;
Zhang, ZF .
ANALYTICAL CHEMISTRY, 2004, 76 (14) :4002-4010
[8]   Synthesis, characterization, and electrochemiluminescence of luminol-reduced gold nanoparticles and their application in a hydrogen peroxide sensor [J].
Cui, Hua ;
Wang, Wei ;
Duan, Chun-Feng ;
Dong, Yong-Ping ;
Guo, Ji-Zhao .
CHEMISTRY-A EUROPEAN JOURNAL, 2007, 13 (24) :6975-6984
[9]   Carbon nanotubes functionalized electrospun nanofibers formed 3D electrode enables highly strong ECL of peroxydisulfate and its application in immunoassay [J].
Dai, Hong ;
Xu, Guifang ;
Zhang, Shupei ;
Gong, Lingshan ;
Li, Xiuhua ;
Yang, Caiping ;
Lin, Yanyu ;
Chen, Jinghua ;
Chen, Guonan .
BIOSENSORS & BIOELECTRONICS, 2014, 61 :575-578
[10]   Single-Cell Pathogen Detection with a Reverse-Phase Immunoassay on Impedimetric Transducers [J].
de la Rica, Roberto ;
Baldi, Antonio ;
Fernandez-Sanchez, Cesar ;
Matsui, Hiroshi .
ANALYTICAL CHEMISTRY, 2009, 81 (18) :7732-7736