A triple-source CT system for micro-scale investigation of geological materials: A simulation study

被引:4
作者
Gao, Xu-Guang [1 ]
Sha, Jun-Feng [1 ]
Luan, Ji-Yuan [1 ]
Li, Meng -Chen [1 ]
Wang, Ji-Peng [1 ]
机构
[1] Shandong Univ, Sch Civil Engn, Jingshi Rd 17922, Jinan 250061, Peoples R China
基金
中国国家自然科学基金;
关键词
CT scanning; Triple-source CT; Image analysis; Positioning error; Dead detector pixels; Numerical simulation; RAY COMPUTED-TOMOGRAPHY; PRINCIPLES; CONCRETE; IMAGE;
D O I
10.1016/j.apradiso.2022.110510
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A triple-source CT system is proposed for micro-scale testing of geological materials. This study aims at reducing the projection acquisition time by two-thirds compared to a conventional single-source CT system. The proposed system with different positioning errors in the source-to-object distance (SOD) was simulated and tested using the Shepp-Logan phantom model, as well as slices of sand, glass beads, and concrete samples. Furthermore, the imaging quality of a single-source and the triple-source CT system with different dead detector pixels was compared. The results showed that within the maximum allowable positioning error, the pixel differences be-tween the simulated and the original images are close to zero, and the structural similarities are greater than 0.96. In the presence of dead detector pixels, the quality of the simulated images in the triple-source CT system is superior to that of a single-source CT system. The presented triple-source CT system performs well in high-quality image reconstruction.
引用
收藏
页数:10
相关论文
共 37 条
[1]   Tolerance to geometrical inaccuracies in CBCT systems: A comprehensive study [J].
Abella, Monica ;
Martinez, Cristobal ;
Garcia, Ines ;
Moreno, Patricia ;
De Molina, Claudia ;
Desco, Manuel .
MEDICAL PHYSICS, 2021, 48 (10) :6007-6019
[2]   A Novel CT Imaging System with Adjacent Double X-Ray Sources [J].
An, Mou ;
Xie, Yaoqin .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
[3]   Investigation of phase composition and microstructure of foamed cement paste with different supplementary cementing materials [J].
Chung, Sang-Yeop ;
Kim, Ji-Su ;
Lehmann, Christian ;
Stephan, Dietmar ;
Han, Tong-Seok ;
Abd Elrahman, Mohamed .
CEMENT & CONCRETE COMPOSITES, 2020, 109 (109)
[4]   Experimental investigation of microstructural changes in soils eroded by suffusion using X-ray tomography [J].
Cong Doan Nguyen ;
Benahmed, Nadia ;
Ando, Edward ;
Sibille, Luc ;
Philippe, Pierre .
ACTA GEOTECHNICA, 2019, 14 (03) :749-765
[5]   A deep learning reconstruction framework for X-ray computed tomography with incomplete data [J].
Dong, Jianbing ;
Fu, Jian ;
He, Zhao .
PLOS ONE, 2019, 14 (11)
[6]   Iterative image reconstruction using non-local means with total variation from insufficient projection data [J].
Ertas, Metin ;
Yildirim, Isa ;
Kamasak, Mustafa ;
Akan, Aydin .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (01) :1-8
[7]   QUANTITATIVE ANALYSIS OF CONCRETE ON THE BASIS OF FUZZY SET AND COMPUTERISED TOMOGRAPHY NUMBER [J].
Fang, Jian-Yin ;
Li, Na ;
Qu, Fei ;
Dou, Zhan-Shuang ;
Li, Shu-Tian .
THERMAL SCIENCE, 2020, 24 (06) :3907-3913
[8]   Towards geometrical calibration of x-ray computed tomography systems-a review [J].
Ferrucci, Massimiliano ;
Leach, Richard K. ;
Giusca, Claudiu ;
Carmignato, Simone ;
Dewulf, Wim .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (09)
[9]   Principles of CT and CT Technology [J].
Goldman, Lee W. .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2007, 35 (03) :115-128
[10]   Nondestructive observation of pores during press forming of aluminum foam by X-ray radiography [J].
Hangai, Yoshihiko ;
Kawato, Daisuke ;
Ando, Mizuki ;
Ohashi, Masataka ;
Morisada, Yoshiaki ;
Ogura, Takuya ;
Fujii, Hidetoshi ;
Nagahiro, Ryohei ;
Amagai, Kenji ;
Utsunomiya, Takao ;
Yoshikawa, Nobuhiro .
MATERIALS CHARACTERIZATION, 2020, 170