Retention force assessment in conical crowns in different material combinations

被引:5
作者
Pietruski, Jan K.
Sajewicz, Eugeniusz [1 ]
Sudnik, Jacek [1 ]
Pietruska, Malgorzata D. [2 ]
机构
[1] Bialystok Tech Univ, Fac Mech Engn, Bialystok, Poland
[2] Med Univ Bialystok, Dept Periodontal & Oral Mucosa Dis, Bialystok, Poland
关键词
retention force; conical crowns; gold casting alloy; gold electroforming alloy; FRICTION; GOLD;
D O I
10.5277/abb130105
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The puprose of this study was to evaluate retention force of conical double crowns in two material connections: gold casting alloy/gold casting alloy and gold casting alloy/gold electroforming alloy. 12 crown pairs of both material connections with the cone angles of 2 degrees, 4 degrees and 6 degrees were made. Experiment of 10.000 in-and-out cycles was performed using a new device which allows the retentive force to be measured in continuous way without necessity of moving the samples to another device. It has been found that the higher the retentive force values, the lower the cone angle. Dispersion of the retention value was similar in both groups, but when cone angle was 2 degrees or 4 degrees, stability of retention force with the passage of time was higher in combinations with electroformed copings. The optimum solution was the cast alloy/cast alloy connection but only with cone angle 6 degrees. However, retentive values seem to be too low to achieve proper retention of dentures.
引用
收藏
页码:35 / 42
页数:8
相关论文
共 22 条
[1]   A NEW TELESCOPIC CROWN SYSTEM USING A SOLDERED HORIZONTAL PIN FOR REMOVABLE PARTIAL DENTURES [J].
AKAGAWA, Y ;
SEO, T ;
OHKAWA, S ;
TSURU, H .
JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (02) :228-231
[2]   Influence of the lubricant and the alloy on the wear behaviour of attachments [J].
Bayer, Stefan ;
Keilig, Ludger ;
Kraus, Dominik ;
Gruener, Manfred ;
Stark, Helmut ;
Mues, Sebastian ;
Enkling, Norbert .
GERODONTOLOGY, 2011, 28 (03) :221-226
[3]  
Besimo C, 1994, INT J PERIODONT RES, V14, P487
[4]  
BUCKLEY D.H., 1981, TRIBOLOGY SERIES, P95
[5]  
Chladek G, 2008, ACTA BIOENG BIOMECH, V10, P7
[6]   CORROSION OF GOLD AND AMALGAM PLACED IN CONTACT WITH EACH OTHER [J].
FUSAYAMA, T ;
NOMOTO, S ;
KATAYORI, T .
JOURNAL OF DENTAL RESEARCH, 1963, 42 (05) :1183-&
[7]   Telescoping implant prostheses with intraoral luted galvano mesostructures to improve passive fit [J].
Greven, Bjoern ;
Luepke, Michael ;
von Dorsche, Soeren Hahn .
JOURNAL OF PROSTHETIC DENTISTRY, 2007, 98 (03) :239-244
[8]   Parameters affecting retentive force of conus crowns [J].
Güngör, MA ;
Artunç, C ;
Sonugelen, M .
JOURNAL OF ORAL REHABILITATION, 2004, 31 (03) :271-277
[9]  
KLIMEK L., 2012, ACTA BIOENG BIOMECH, P14
[10]   ATTACHMENT FIXATION OF OVERDENTURE .2. [J].
MENSOR, MC .
JOURNAL OF PROSTHETIC DENTISTRY, 1978, 39 (01) :16-20