Time-Domain Modeling of Grounding Systems' Impulse Response Incorporating Nonlinear and Frequency-Dependent Aspects

被引:52
作者
Kherif, Omar [1 ]
Chiheb, Sofiane [1 ]
Teguar, Madjid [1 ]
Mekhaldi, Abdelouahab [1 ]
Harid, Noureddine [2 ]
机构
[1] Ecole Natl Polytech, Lab Rech Electrotech, Algiers 16200, Algeria
[2] Petr Inst, Elect Engn Dept, Abu Dhabi 2533, U Arab Emirates
关键词
Frequency dependence; grounding; impulse response; lightning; modeling; mutual coupling; soil ionization; transient analysis; transmission line approach; two-layer soil; SOIL; ELECTRODES; PARAMETERS; ROD;
D O I
10.1109/TEMC.2017.2751564
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
At lightning discharge, the grounding systems' transient behavior is influenced by time-dependent nonlinear behavior and frequency-dependent effects. These effects are related to complex phenomena arising from the soil ionization surrounding the conductors at high current and to the fast risetime of the impulse current, respectively. Most of the performed investigations were either focused on soil ionization effects or frequency-dependent effects. This paper proposes a model that incorporates both aspects including the mutual coupling and air-soil interface effects, giving a more realistic representation of the grounding systems behavior. Based on the transmission line approach, the model can compute the grounding systems transient response buried in uniform and nonuniform soil. The model is applied to horizontal, vertical electrodes, and grounding grid subjected to impulse currents of variable magnitudes and shapes. The model results are validated against published measurement results obtained with low-current and high-current impulses. The time-domain transient potential and transient impedances show good agreement with experimental results. Other impulse impedance parameters used for the grounding systems analysis are reproduced quite accurately. As an application, the impulse impedance of a horizontal electrode and a grounding grid buried in two-layer soil is discussed when the upper layer depth and the resistivity of soil layers are varied.
引用
收藏
页码:907 / 916
页数:10
相关论文
共 33 条
  • [1] Time-Domain Analysis of Frequency-Dependent Electrical Parameters of Soil
    Alipio, Rafael
    Visacro, Silverio
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2017, 59 (03) : 873 - 878
  • [2] Aerial and grounding system analysis by the shifting complex images method
    Andolfato, R
    Bernardi, L
    Fellin, L
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (03) : 1001 - 1009
  • [3] Cavka D., 2013, ELECTROMAGNETIC COMP, P1
  • [4] Computation of ground resistances and assessment of ground grid safety at 161/23.9-kV indoor-type substation
    Chang, Cheng Nan
    Lee, Chien-Hsing
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) : 1250 - 1260
  • [5] CIGRE WG C4. 501, 2013, C4501 CIGRE WG
  • [6] Clark D, 2014, P INT C GROUND EARTH, P196
  • [7] Extension of a modal-domain transmission line model to include frequency-dependent ground parameters
    De Conti, Alberto
    Emidio, Maique Paulo S.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2016, 138 : 120 - 130
  • [8] Elzowawi A, 2015, P INT U POW ENG C ST, P1
  • [9] The Transmission Line Modeling Method to Represent the Soil Ionization Phenomenon in Grounding Systems
    Gazzana, Daniel S.
    Bretas, Arturo S.
    Dias, Guilherme A. D.
    Tello, Marcos
    Thomas, Dave W. P.
    Christopoulos, Christos
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (02) : 505 - 508
  • [10] Behaviour of grounding systems excited by high impulse currents: the model and its validation
    Geri, A
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (03) : 1008 - 1017