Polar monolithic capillary columns for the molecular-mass separation of polystyrene standards are synthesized on the basis of ethylene glycol dimethacrylate. The monolith structure is optimized through variation in the type of porogen because variation in other synthesis parameters (the time and temperature of polymerization, the amount of monomer in the initial feed) is inefficient. The separation of polymers on monolithic sorbents proceeds via a combined exclusion-hydrodynamic mechanism. In terms of a model that allows for contributions of both mechanisms to retention, calibration plots are drawn for the synthesized columns. Monolithic columns with the optimum monolith structure make it possible to use up to 60% of the column free volume for the efficient separation of polymers in a broad molecular-mass range.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 31 条
[1]   Determination of the porosities of monolithic columns by inverse size-exclusion chromatography [J].
Al-Bokari, M ;
Cherrak, D ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (02) :275-284
[2]  
Bird R.B., 1962, Transport Phenomena
[3]  
DiMarzio E.A., 1970, MACROMOLECULES, V3, P131, DOI [DOI 10.1021/MA60014A005, 10.1021/ma60014a005]
[4]   Influence of the polymerisation time on the porous and chromatographic properties of monolithic poly(1,2-bis(p-vinylphenyl))ethane capillary columns [J].
Greiderer, Andreas ;
Trojer, Lukas ;
Huck, Christian W. ;
Bonn, Guenther K. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (45) :7747-7754
[5]   Pore structural characterization of monolithic silica columns by inverse size-exclusion chromatography [J].
Grimes, Brian A. ;
Skudas, Romas ;
Unger, Klaus K. ;
Lubda, Dieter .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1144 (01) :14-29
[6]   Column efficiency and separation of DNA fragments using slalom chromatography: Hydrodynamic study and fractal considerations [J].
Guillaume, YC ;
Peyrin, E ;
Thomassin, M ;
Ravel, A ;
Grosset, C ;
Villet, A ;
Robert, JF ;
Guinchard, C .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4846-4852
[7]   Separation in slalom chromatography: Stretching and velocity dependence [J].
Guillaume, YC ;
Perrin, FX ;
Guinchard, C ;
Nicod, L ;
Truong, TT ;
Xicluna, A ;
Millet, J ;
Thomassin, M .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1217-1222
[8]   A mathematical model for hydrodynamic and size exclusion chromatography of polymers on porous particles [J].
Guillaume, YC ;
Robert, JF ;
Guinchard, C .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :3059-3064
[9]   Monolithic columns in high-performance liquid chromatography [J].
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1168 (1-2) :101-168
[10]   Applied slalom chromatography. Improved DNA separation by the use of columns developed for reversed-phase chromatography [J].
Hirabayashi, J ;
Kasai, K .
JOURNAL OF CHROMATOGRAPHY A, 1996, 722 (1-2) :135-142