Polarization-sensitive optical coherence tomography based on polarization-maintaining fibers and frequency multiplexing

被引:55
作者
Al-Qaisi, Muhammad K. [1 ]
Akkin, Taner [1 ]
机构
[1] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1364/OE.16.013032
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report a novel polarization-maintaining fiber based optical coherence tomography for single detector imaging of tissue reflectivity and birefringence. A single depth scan yields quantitative birefringence information along the A-line accurately. Since the orthogonal polarization channels are frequency multiplexed, the polarization information is extracted by using digital band-pass filters. Here, we introduce the optical system and present the reflectivity and birefringence images of biological tissues with an axial resolution of 7.9 mu m and SNR of 30 dB. (C) 2008 Optical Society of America.
引用
收藏
页码:13032 / 13041
页数:10
相关论文
共 29 条
  • [1] Single camera based spectral domain polarization sensitive optical coherence tomography
    Baumann, Bernhard
    Goetzinger, Erich
    Pircher, Michael
    Hitzenberger, Christoph K.
    [J]. OPTICS EXPRESS, 2007, 15 (03): : 1054 - 1063
  • [2] Polarization-sensitive spectral-domain optical coherence tomography using a single line scan camera
    Cense, Barry
    Mujat, Mircea
    Chen, Teresa C.
    Park, B. Hyle
    de Boer, Johannes F.
    [J]. OPTICS EXPRESS, 2007, 15 (05): : 2421 - 2431
  • [3] Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    Choma, MA
    Sarunic, MV
    Yang, CH
    Izatt, JA
    [J]. OPTICS EXPRESS, 2003, 11 (18): : 2183 - 2189
  • [4] Polarization-maintaining fiber-based optical low-coherence reflectometer for characterization and ranging of birefringence
    Davé, DP
    Akkin, T
    Milner, TE
    [J]. OPTICS LETTERS, 2003, 28 (19) : 1775 - 1777
  • [5] Optical low-coherence reflectometer for differential phase measurement
    Davé, DP
    Milner, TE
    [J]. OPTICS LETTERS, 2000, 25 (04) : 227 - 229
  • [6] Phase-sensitive frequency-multiplexed optical low-coherence reflectometery
    Davé, DP
    Akkin, T
    Milner, TE
    Rylander, HG
    [J]. OPTICS COMMUNICATIONS, 2001, 193 (1-6) : 39 - 43
  • [7] Polarization effects in optical coherence tomography of various biological tissues
    de Boer, JF
    Srinivas, SM
    Park, BH
    Pham, TH
    Chen, ZP
    Milner, TE
    Nelson, JS
    [J]. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) : 1200 - 1204
  • [8] Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
    de Boer, JF
    Cense, B
    Park, BH
    Pierce, MC
    Tearney, GJ
    Bouma, BE
    [J]. OPTICS LETTERS, 2003, 28 (21) : 2067 - 2069
  • [9] Determination of the depth-resolved Stokes parameters of light backscattered from turbid media by use of polarization-sensitive optical coherence tomography
    de Boer, JF
    Milner, TE
    Nelson, JS
    [J]. OPTICS LETTERS, 1999, 24 (05) : 300 - 302
  • [10] Drexler W, 2001, J RHEUMATOL, V28, P1311