Evaluation of in-stent neointimal tissue components using integrated backscatter intravascular ultrasound: comparison of drug-eluting stents and bare-metal stents

被引:10
|
作者
Muraoka, Yoshitaka [1 ]
Sonoda, Shinjo [1 ]
Kashiyama, Kuninobu [1 ]
Kamezaki, Fumihiko [1 ]
Tsuda, Yuki [1 ]
Araki, Masaru [1 ]
Okazaki, Masahiro [1 ]
Otsuji, Yutaka [1 ]
机构
[1] Univ Occupat & Environm Hlth, Dept Cardiovasc Med, Yahatanishi Ku, Kitakyushu, Fukuoka 8078555, Japan
关键词
Drug-eluting stents; Bare-metal stents; Neointima; Integrated backscatter intravascular ultrasound; CORONARY RESTENOSIS; IMPLANTATION; PACLITAXEL; PATTERNS; POLYMER; HYPERPLASIA; PLAQUES;
D O I
10.1007/s10554-011-9997-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although in-stent restenosis (ISR) occurs after drug-eluting stents (DES) implantation, neointimal tissue characteristics have not been fully investigated. We assessed neointimal tissue components using integrated backscatter intravascular ultrasound (IB-IVUS) after DES and bare-metal stents (BMS) implantation. Fifty-seven consecutive patients with 61 lesions underwent repeated percutaneous coronary intervention (PCI) for the treatment of ISR (DES: 24 lesions, BMS: 37 lesions). PCI was performed using plain old balloon angioplasty (POBA). Before PCI, we assessed neointimal tissue characteristics using IB-IVUS. Neointima was divided into four categories: category 1 (-11 to -29 dB), category 2 (-29 to -35 dB), category 3 (-35 to -49 dB), and category 4 (-49 to -130 dB) according to IB values. We compared neointimal tissue components between DES and BMS. Thirty-three patients with 33 lesions (DES: 17, BMS: 16) were finally included. Neointima was predominantly composed of category 3 tissue in both groups (DES: 68 +/- A 8%, BMS: 73 +/- A 5%, P = 0.053). DES had a broader distribution of category 4 tissue component than BMS. After POBA, distal slow flow phenomenon occurred in 5 of DES (29%), whereas none of BMS. In DES, the optimal threshold of category 4 tissue to predict distal slow flow phenomenon after POBA was 30% (sensitivity: 100%, specificity: 92%). Neointima was mainly composed of category 3 tissue at ISR site, irrespective of DES or BMS. In DES, there was a subgroup with category 4 rich tissue, which caused distal slow flow phenomenon after POBA. IB-IVUS might be useful to identify vulnerable neointima in DES restenosis.
引用
收藏
页码:1635 / 1641
页数:7
相关论文
共 50 条
  • [31] Impact of Drug-Eluting Versus Bare-Metal Stents on Mortality in Patients With Anemia
    Shishehbor, Mehdi H.
    Filby, Steven J.
    Chhatriwalla, Adnan K.
    Christofferson, Ryan D.
    Jain, Anil
    Kapadia, Samir R.
    Lincoff, A. Michael
    Bhatt, Deepak L.
    Ellis, Stephen G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (04) : 329 - 336
  • [32] Difference of Neoatherosclerosis Pattern in Lesions With In-Stent Restenosis Among Bare-Metal, First and Second Generation Drug-Eluting Stents
    Nakamura, Daisuke
    Nishino, Masami
    Yasumura, Keisuke
    Yasumoto, Koji
    Tanaka, Akihiro
    Mori, Naoki
    Yano, Masamichi
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    CIRCULATION, 2017, 136
  • [33] Long-term changes in neointimal hyperplasia following implantation of bare metal stents assessed by integrated backscatter intravascular ultrasound
    Tanaka, Shinichiro
    Noda, Toshiyuki
    Iwama, Makoto
    Tanihata, Shintaro
    Kawasaki, Masanori
    Nishigaki, Kazuhiko
    Minagawa, Taro
    Watanabe, Sachiro
    Minatoguchi, Shinya
    HEART AND VESSELS, 2013, 28 (04) : 415 - 423
  • [34] Femoropopliteal Drug-Eluting Versus Bare-Metal Stents Lost a BATTLE, But Not the War!
    Aronow, Herbert D.
    Saad, Marwan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (04) : 458 - 460
  • [35] Time Dependency of Outcomes for Drug-Eluting vs Bare-Metal Stents
    Leung, Alexander A.
    Southern, Danielle A.
    Galbraith, P. Diane
    Knudtson, Merril L.
    Philpott, Andrew C.
    Ghali, William A.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (12) : 1616 - 1622
  • [36] Drug-eluting or bare-metal stents in interventional cardiology. Theory and Practice
    Er, Fikret
    Erdmann, Erland
    MEDIZINISCHE KLINIK, 2007, 102 (01) : 30 - 32
  • [37] Effect of Length and Diameter of Drug-Eluting Stents Versus Bare-Metal Stents on Late Outcomes
    Applegate, Robert J.
    Sacrinty, Matthew T.
    Kutcher, Michael A.
    Santos, Renato M.
    Gandhi, Sanjay K.
    Little, William C.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (01) : 35 - 42
  • [38] Comparison Between Bare-Metal Stents, First-Generation Drug-Eluting Stents, and Bioresorbable Vascular Scaffolds
    Ng, Andrew Kei-Yan
    Ng, Pauline Yeung
    Siu, Chung-Wah
    Jim, Man-Hong
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (06) : E467 - E473
  • [39] Effect of Stent Thrombosis on the Risk-Benefit Balance of Drug-Eluting Stents and Bare Metal Stents
    Flores-Rios, Xacobe
    Abugattas-de Torres, Juan P.
    Campo-Perez, Rosa
    Pinon-Esteban, Pablo
    Aldama-Lopez, Guillermo
    Salgado-Fernandez, Jorge
    Calvino-Santos, Ramon
    Vazquez-Rodriguez, Jose M.
    Vazquez-Gonzalez, Nicolas
    Castro-Beiras, Alfonso
    REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (05): : 528 - 535
  • [40] The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography
    Sato, Kastsumasa
    Costopoulos, Charis
    Takebayashi, Hideo
    Naganuma, Toru
    Miyazaki, Tadashi
    Goto, Kenji
    Yamane, Hiroki
    Hagikura, Arata
    Kikuta, Yuetsu
    Taniguchi, Masahito
    Hiramatsu, Shigeki
    Ito, Hiroshi
    Colombo, Antonio
    Haruta, Seiichi
    JOURNAL OF CARDIOLOGY, 2014, 64 (5-6) : 488 - 495