Influence of electrochemical corrosion tests in an artificial environment on the chemical composition of a Co-Cr-Mo dental alloy

被引:0
作者
Baciu, E. R. [1 ]
Baciu, C. [2 ]
Bosinceanu, D. G. [1 ]
Baciu, M. A. [2 ]
Bosinceanu, D. N. [1 ]
Baciu, M. [2 ]
Bulancea, B. [1 ]
机构
[1] Gr T Popa Univ Med & Pharm Iasi Romania, Fac Med Dent, 16 Univ St, Iasi 700115, Romania
[2] Gheorghe Asachi Tech Univ Iasi Romania, Fac Mat Sci & Engn, Blvd Dimitrie Mangeron 67, Iasi 700050, Romania
来源
MODTECH INTERNATIONAL CONFERENCE - MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING VI (MODTECH 2018) | 2018年 / 400卷
关键词
BEHAVIOR; COBALT;
D O I
10.1088/1757-899X/400/2/022008
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The goal of this study consists in the determination of structural modifications produced in a non-noble alloy intended for metal components of the skeletonized removable partial dentures following electrochemical corrosion in artificial saliva. The behavior to electrochemical corrosion was shown by the microstructural and chemical analysis by means of an electron scanning microscope fitted with an EDAX electron detector. We noticed that on the analyzed surface of Co-Cr-Mo alloy (Remanium GM 800, Dentaurum) that the Co and Mo elements lost their initial mass percentage, whereas others like Si increased their mass percentage with a very small quantity, a fact indicating the corrosion of Co and Mo elements and a better resistance of silicon. Following the determinations made, we may affirm that Co-Cr-Mo alloy (Remanium GM 800, Dentaurum) has a behavior to electrochemical corrosion in artificial saliva of generalized type and preferential by phases, with oxidization on the entire surface of the material and the formation of a superficial corrosion layer on the phase of matrix type.
引用
收藏
页数:6
相关论文
共 14 条
[1]  
[Anonymous], 2000, CORROSION METAL ENV
[2]  
Bellefontaine G, 2010, CORROSION COCRMO ALL, P13
[3]   Electrochemical behavior of CoCrMo alloy in the active state in acidic and alkaline buffered solutions [J].
Contu, F ;
Elsener, B ;
Böhni, H .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2003, 150 (09) :B419-B424
[4]  
Crook P, 1990, METALS HDB NONFERROU, P447
[5]   Elemental ion release from four different fixed prosthodontic materials [J].
Elshahawy, Waleed ;
Watanabe, Ikuya ;
Koike, Mari .
DENTAL MATERIALS, 2009, 25 (08) :976-981
[6]  
Galo R, 2012, BRAZILIAN DENT J, V23
[7]   Electrochemical corrosion studies on Co-Cr-Mo implant alloy in biological solutions [J].
Hsu, RWW ;
Yang, CC ;
Huang, CA ;
Chen, YS .
MATERIALS CHEMISTRY AND PHYSICS, 2005, 93 (2-3) :531-538
[8]  
Kauser F., 2007, CORROSION COCR MO AL, P4
[9]   Simple isolation method for the bulk isolation of wear particles from metal on metal bearing surfaces generated in a hip simulator test [J].
Lu, Fang ;
Royle, Matt ;
Lali, Ferdinand V. ;
Hart, Alister J. ;
Collins, Simon ;
Housden, Jonathan ;
Shelton, Julia C. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2012, 23 (04) :891-901
[10]   CORROSION RESISTANCE OF Co-Cr-Mo ALLOY USED IN DENTISTRY [J].
Lukaszczyk, A. ;
Augustyn-Pieniazek, J. .
ARCHIVES OF METALLURGY AND MATERIALS, 2015, 60 (01) :523-528