A Two-Year Evaluation of Corrosion-Induced Damage to Hot Galvanized Reinforcing Steel B500SP in Chloride Contaminated Concrete

被引:7
作者
Jasniok, Mariusz [1 ]
Sozanska, Maria [2 ]
Kolodziej, Jacek [1 ]
Chmiela, Bartosz [2 ]
机构
[1] Silesian Tech Univ, Fac Civil Engn, 5 Akad, PL-44100 Gliwice, Poland
[2] Silesian Tech Univ, Fac Mat Engn, 8 Krasinskiego, PL-40019 Katowice, Poland
关键词
concrete; reinforcing steel; zinc coating; HDG; corrosion; chlorides; LPR; EIS; SEM; EDS; CARBONATED CONCRETE; INDUCED CRACKING; BOND-STRENGTH; REBARS; REINFORCEMENTS; TEMPERATURE; PERFORMANCE; MECHANISM; THICKNESS; BEHAVIOR;
D O I
10.3390/ma13153315
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Corrosion-induced damage to concrete reinforced with bars is a serious problem regarding technical and economic aspects and strongly depends on used materials, corrosion environment, and service life. Tests described in this paper refer to a two-year evaluation of the effectiveness of protection provided by zinc-coated low-carbon reinforcing steel of grade B500SP in concrete against chloride corrosion. Performed tests were comparative and included measurements conducted on four groups of concrete test elements with dimensions of 40 mm x 40 mm x 140 mm reinforced with a bar having a diameter of phi 8 mm. Particular groups were a combination of different types of concrete with or without chloride additives, with galvanized or black steel. Chlorides as CaCl(2)were added to the concrete mix in the amount of 3% of cement weight in concrete. Reinforced concrete specimens were periodically monitored within two years using the following techniques: linear polarization resistance (LPR) and electrochemical impedance spectroscopy (EIS). Polarization measurements were conducted in a three-electrode arrangement, in which a rebar in concrete served as a working electrode, stainless steel sheet was used as an auxiliary electrode, and Cl-/AgCl,Ag was a reference electrode. Comparative tests of changes in the density of corrosion current in concrete specimens without chloride additives basically demonstrated no development of corrosion, and possible passivation was expected in case of black steel. Higher densities of corrosion current were observed for galvanized steel during first days of testing. The reason was the dissolution of zinc after the contact with initially high pH of concrete pore solution. Six-month measurements demonstrated a higher density of corrosion current in concrete specimens with high concentration of chlorides, which unambiguously indicated corrosion in concrete reinforced with galvanized or black steel. Densities of corrosion current determined for selected specimens dramatically decreased after an 18-month interval in measurements. Corrosion was even inhibited on black steel as an insulating barrier of corrosion products was formed. The above observations were confirmed with structural studies using scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) techniques. Results obtained from corrosion (LPR, EIS) and structural (SEM, EDS) tests on specimens of concrete reinforced with steel B500SP demonstrated a very favorable impact of zinc coating on steel by providing two-year protection against corrosion in the environment with very high chloride content.
引用
收藏
页数:26
相关论文
共 53 条
[1]   On-site measurements of corrosion rate of reinforcements [J].
Andrade, C ;
Alonso, C .
CONSTRUCTION AND BUILDING MATERIALS, 2001, 15 (2-3) :141-145
[2]  
Andrade C., 2004, Galvanized Steel Reinforcement in Concrete, P111, DOI [10.1016/B978-008044511-3/50020-7, DOI 10.1016/B978-008044511-3/50020-7]
[3]   The steel-concrete interface [J].
Angst, Ueli M. ;
Geiker, Mette R. ;
Michel, Alexander ;
Gehlen, Christoph ;
Wong, Hong ;
Isgor, O. Burkan ;
Elsener, Bernhard ;
Hansson, Carolyn M. ;
Francois, Raoul ;
Hornbostel, Karla ;
Polder, Rob ;
Alonso, Maria Cruz ;
Sanchez, Mercedes ;
Correia, Maria Joao ;
Criado, Maria ;
Sagues, A. ;
Buenfeld, Nick .
MATERIALS AND STRUCTURES, 2017, 50 (02)
[4]  
[Anonymous], 2009, FIB B, V49
[5]  
[Anonymous], 2017, A123A123M ASTM
[6]  
[Anonymous], 1999, C87691 ASTM
[7]  
[Anonymous], 2015, A767A767M ASTM
[8]  
[Anonymous], 2016, 206A1 EN
[9]  
[Anonymous], 2008, 199211 EN
[10]   EIS study of passivation of austenitic and duplex stainless steels reinforcements in simulated pore solutions [J].
Blanco, G ;
Bautista, A ;
Takenouti, H .
CEMENT & CONCRETE COMPOSITES, 2006, 28 (03) :212-219