A system for high-resolution X-ray phase-contrast imaging and tomography of biological specimens

被引:3
作者
Poletto, Luca [1 ]
Caldon, Matteo [1 ]
Tondello, Giuseppe [1 ]
机构
[1] CNR, Natl Inst Phys Matter Italy, Lab UV & Xray Opt Res, Dept Informat Engn, Padua, Italy
来源
DEVELOPMENTS IN X-RAY TOMOGRAPHY VI | 2008年 / 7078卷
关键词
X-ray tomography; phase-contrast imaging;
D O I
10.1117/12.793001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A system for high-resolution X-ray diagnostics is presented. It consists of a microfocus X-ray source with spot size of 5 mu m that is operated in the 10-90 kV range. The detector is a Ce:YAG crystal coupled to a CCD camera with 5 mu m pixel size and 1392x1040 format. The magnification of the optical coupling is chosen in the 1 to 4 range, giving a spatial resolving element of 5 to 20 pm. The sample to be acquired is mounted on a motorized rototranslation stage for the automatic acquisition of the X-tay views both for tomography and phase-contrast imaging. The sample is positioned half-way between the source and the detector. X-ray images show very high contrast due to phase effects in addition to absorption. Some images of biological specimens are presented to assess the capability of revealing very low differences in density due to the presence of phase contrast. A complete high-resolution tomography of a drosophila is presented.
引用
收藏
页数:10
相关论文
共 12 条
  • [1] RECENT APPLICATIONS OF X-RAYS IN CONDENSED MATTER PHYSICS
    ALSNIELSEN, J
    MATERLIK, G
    [J]. PHYSICS TODAY, 1995, 48 (11) : 34 - 40
  • [2] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [3] HENDEE W, 1999, BIOMEDICAL USES RAD, P73705
  • [4] KAK AC, 1988, PRINCIPLES COMPUTERI, P73705
  • [5] KALENDER WA, 2005, COMPUTED TOMOGRAPHY, P73705
  • [6] X-ray phase-contrast microscopy and microtomography
    Mayo, SC
    Davis, TJ
    Gureyev, TE
    Miller, PR
    Paganin, D
    Pogany, A
    Stevenson, AW
    Wilkins, SW
    [J]. OPTICS EXPRESS, 2003, 11 (19): : 2289 - 2302
  • [7] MILLS DM, 2002, 3 GENERATION HARD XR, P73705
  • [8] NESTERETS YI, 1995, REV SCI INSTRUM, V76, P73705
  • [9] Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
    Pfeiffer, F
    Weitkamp, T
    Bunk, O
    David, C
    [J]. NATURE PHYSICS, 2006, 2 (04) : 258 - 261
  • [10] IMAGE-RECONSTRUCTION FROM CONE-BEAM PROJECTIONS - NECESSARY AND SUFFICIENT CONDITIONS AND RECONSTRUCTION METHODS
    SMITH, BD