Development of a hollow fiber membrane module for using implantable artificial lung

被引:20
作者
Kim, Gi-Beum [1 ,5 ]
Kim, Seong-Jong [2 ]
Kim, Min-Ho [3 ]
Hong, Chul-Un [4 ,5 ]
Kang, Hyung-Sub [1 ,5 ]
机构
[1] Chonbuk Natinaol Univ, Coll Vet Med, Dept Pharmacol, Jeonju, Jeonbuk, South Korea
[2] Chonbuk Natinaol Univ, Coll Engn, Div Chem Engn, Jeonju, Jeonbuk, South Korea
[3] Chonbuk Natinaol Univ, Chonbuk Natl Univ, Sch Med, Dept Thorac & Cardiovasc Surg, Jeonju, Jeonbuk, South Korea
[4] Chonbuk Natinaol Univ, Coll Engn, Div Biomed Engn, Jeonju, Jeonbuk, South Korea
[5] Chonbuk Natinaol Univ, Ctr Healthcare Technol Dev, Jeonju, Jeonbuk, South Korea
关键词
Intravascular lung; Hemolysis; Vibration; Gas transfer; ACUTE RESPIRATORY-FAILURE; OXYGENATOR; REMOVAL;
D O I
10.1016/j.memsci.2008.09.045
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study examined the effects of multiple mechanical forces on gas exchange and hemolysis in intravascular lung assist devices (IVLAD). Specific attention was paid to on the effect of membrane vibration. This study adhered to the recommended practice for the assessment of hemolysis described by the American Society of Testing and Materials (ASTM). The results showed a higher oxygen (O-2) transfer rate and carbon dioxide (CO2) removal rate in each excited frequency bandwidth than those without vibration. The maximum oxygen transfer and carbon dioxide removal rate occurred at frequency band of 7 Hz. The gas exchange improved maximum 52%. The plasma-free hemoglobin was 11.2 +/- 0.57 and 14.4 +/- 0.74 mg/100 ml by exciting a piezo-vibrator with a sinusoidal wave magnitude of DC10V and DC50V, respectively. The NIHO value was determined to be 59 +/- 2.76 and 95 +/- 432 mg/100 ml by exciting a piezo-vibrator with a sinusoidal wave magnitude of DC10V and DC50V, respectively. In conclusion, piezoelectric lead zirconate titanate (PZT) materials are exciting systems for improving the oxygen transfer efficiency and blood suitability of hollow fiber membrane in the development of new IVLAD. Crown Copyright (C) 2008 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:130 / 136
页数:7
相关论文
共 14 条
[1]   INTRAVENACAVAL MEMBRANE-OXYGENATION AND CARBON-DIOXIDE REMOVAL IN SEVERE ACUTE RESPIRATORY-FAILURE [J].
CONRAD, SA ;
EGGERSTEDT, JM ;
GRIER, LR ;
MORRIS, VF ;
ROMERO, MD .
CHEST, 1995, 107 (06) :1689-1697
[2]   Analysis of in vitro continuous wet-dry CO2 removal with hydrophilic membranes from slowly flowing blood [J].
Czermak, P ;
Walz, M ;
Catapano, G .
JOURNAL OF MEMBRANE SCIENCE, 2006, 273 (1-2) :89-96
[3]   Recent progress in engineering the Pittsburgh intravenous membrane oxygenator [J].
Federspiel, WJ ;
Hewitt, T ;
Hout, MS ;
Walters, FR ;
Lund, LW ;
Sawzik, PJ ;
Reeder, G ;
Borovetz, HS ;
Hattler, BG .
ASAIO JOURNAL, 1996, 42 (05) :M435-M442
[4]  
Hattler B G, 1992, ASAIO J, V38, pM322, DOI 10.1097/00002480-199207000-00046
[5]  
HOOKER T P, 1992, Journal of the American Osteopathic Association, V92, P886
[6]   RATE OF THROMBUS ACCUMULATION ON INTRAVENACAVAL IVOX DEVICES EXPLANTED FROM HUMAN CLINICAL-TRIAL PATIENTS WITH ACUTE RESPIRATORY-FAILURE [J].
IMAI, H ;
SCHAAP, RN ;
MORTENSEN, JD .
ARTIFICIAL ORGANS, 1994, 18 (11) :818-821
[7]   Enhancement of oxygen transfer in hollow fiber membrane by the vibration method [J].
Kim, GB ;
Kim, SJ ;
Hong, CU ;
Kwon, TK ;
Kim, NG .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2005, 22 (04) :521-527
[8]   Vibration characteristics of piezoelectric lead zirconate titanate by fluid flow in intravascular oxygenator [J].
Kim, Gi-Beum ;
Hong, Chul-Un ;
Kwon, Tae-Kyu .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (4B) :3811-3817
[9]  
Kim N, 2006, J HIGH ENERGY PHYS
[10]   Preclinical evaluation of a hollow fiber silicone membrane oxygenator for extracorporeal membrane oxygenator application [J].
Maeda, T ;
Iwasaki, A ;
Kawahito, S ;
Nakata, K ;
Nonaka, K ;
Linneweber, J ;
Shulte-Eistrup, S ;
Takano, T ;
Yoshikawa, M ;
Sato, K ;
Kuwana, J ;
Murabayashi, S ;
Nosé, Y .
ASAIO JOURNAL, 2000, 46 (04) :426-430