Evaluation of the enantioselectivity of glycogen-based synergistic system with amino acid chiral ionic liquids as additives in capillary electrophoresis

被引:54
作者
Zhang, Qi [1 ]
Du, Yingxiang [1 ,2 ,3 ]
机构
[1] China Pharmaceut Univ, Dept Analyt Chem, Nanjing 210009, Jiangsu, Peoples R China
[2] China Pharmaceut Univ, Minist Educ, Key Lab Drug Qual Control & Pharmacovigilance, Nanjing 210009, Peoples R China
[3] China Pharmaceut Univ, State Key Lab Nat Med, Nanjing 210009, Peoples R China
基金
中国国家自然科学基金;
关键词
Capillary electrophoresis; Enantiomeric separation; Chiral ionic liquids; Amino acid ionic liquids; Glycogen; Synergistic system; BASIC DRUGS; ENANTIOMERIC SEPARATION; ELECTROKINETIC CHROMATOGRAPHY; CLINDAMYCIN PHOSPHATE; ENANTIOSEPARATION; SELECTOR; POLYSACCHARIDES; CYCLODEXTRINS; LACTOBIONATE; DESIGN;
D O I
10.1016/j.chroma.2013.07.053
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, two novel amino acid chiral ILs, tetramethylammonium-L-arginine (TMA-L-Arg) and tetramethylammonium-L-aspartic acid (TMA-L-Asp), were applied for the first time in CE enantioseparation to evaluate their potential synergistic effect with glycogen as chiral selector. As observed, significantly improved separation of tested enantiomers were obtained in the chiral ILs/glycogen synergistic systems compared to the single glycogen separation system. Several primary parameters affecting the enantioseparation, such as amino acid ILs (AAILs) concentration, glycogen concentration and buffer pH, were systematically investigated. An achiral tetramethylammonium hydroxide ionic liquid (TMA-OH) modified separation system was also evaluated to validate the superiority of the novel chiral ILs/glycogen synergistic systems. To further optimize the overall synergistic systems, the effect of three other parameters, including buffer concentration, applied voltage and capillary temperature were simultaneously analyzed by a central composite design (CCD), and excellent enantioseparations were achieved with the optimized parameters. The results indicate that the application of chiral ILs/glycogen synergistic systems is a promising way in chiral separation science. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 43 条
[1]   Enantioseparation using selected polysaccharides as chiral buffer additives in capillary electrophoresis [J].
Chankvetadze, B ;
Saito, M ;
Yashima, E ;
Okamoto, Y .
JOURNAL OF CHROMATOGRAPHY A, 1997, 773 (1-2) :331-338
[2]   Enantioseparations by using capillary electrophoretic techniques The story of 20 and a few more years [J].
Chankvetadze, Bezhan .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1168 (1-2) :45-70
[3]   Evaluation of the enantioseparation capability of the novel chiral selector clindamycin phosphate towards basic drugs by micellar electrokinetic chromatography [J].
Chen, Bin ;
Du, Yingxiang .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (11) :1806-1812
[4]   Study on enantiomeric separation of basic drugs by NACE in methanol-based medium using erythromycin lactobionate as a chiral selector [J].
Chen, Bin ;
Du, Yingxiang ;
Wang, Hao .
ELECTROPHORESIS, 2010, 31 (02) :371-377
[5]   Investigation of enantiomeric separation of basic drugs by capillary electrophoresis using clindamycin phosphate as a novel chiral selector [J].
Chen, Bin ;
Du, Yingxiang ;
Li, Ping .
ELECTROPHORESIS, 2009, 30 (15) :2747-2754
[6]   Evaluation of the enantioselectivity of glycogen-based dual chiral selector systems towards basic drugs in capillary electrophoresis [J].
Chen, Jiaquan ;
Du, Yingxiang ;
Zhu, Fenxia ;
Chen, Bin .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (45) :7158-7163
[7]   Glycogen: A novel branched polysaccharide chiral selector in CE [J].
Chen, Jiaquan ;
Du, Yingxiang ;
Zhu, Fenxia ;
Chen, Bin .
ELECTROPHORESIS, 2010, 31 (06) :1044-1050
[8]  
Daali Y, 1999, ELECTROPHORESIS, V20, P3424, DOI 10.1002/(SICI)1522-2683(19991101)20:17<3424::AID-ELPS3424>3.3.CO
[9]  
2-Q
[10]  
Du YX, 2010, CHIM OGGI, V28, P37