Subjective assessment of depth of anaesthesia by experienced and inexperienced anaesthetists

被引:6
作者
Hadzidiakos, D [1 ]
Nowak, A [1 ]
Laudahn, N [1 ]
Baars, J [1 ]
Herold, K [1 ]
Rehberg, B [1 ]
机构
[1] Charite Univ Med Berlin, Dept Anaesthesiol, D-10117 Berlin, Germany
关键词
anaesthesia general; monitoring; depth of anaesthesia; anaesthesiology; learning; task performance and analysis; awareness; anaesthesia;
D O I
10.1017/S026502150600010X
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: To measure 'depth of anaesthesia', anaesthesiologists use a combination of observable end-points such as immobility and autonomic stability. Unconsciousness and amnesia are not reliably observable end-points, but correlate with parameters derived from the electroencephalogram. We investigated the association of subjective assessment and electroencephalographic measures of anaesthetic depth in a group of experienced (> 4 yr of experience) and a group of inexperienced (< 2 yr of experience) anaesthesiologists. Methods: One hundred ASA I or II patients were assigned to either group. Anaesthesiologists assessed 'anaesthetic depth' using an 11-point numeric and a 5-point verbal scale. Bispectral index and spectral entropy were recorded as electroencephalogram parameters. The association between the subjective assessment and the electroencephalogram parameters was calculated using the prediction probability, P-K. Results: Association between subjective assessment and electroencephalographic parameters showed a tendency to a better prediction probability in the experienced group. The difference was significant (P < 0.05) for the bispectral index (P-K 0.76 +/- 0.01 for experienced and 0.71 +/- 0.01 for inexperienced anaesthesiologists). In both groups, a large percentage of the data points recorded during surgery showed bispectral index values above the recommended value of 60 (13.2% in the experienced and 34.3% in the inexperienced group) despite a subjective assessment of 'deep' or 'very deep' anaesthetic depth. Conclusion: The study demonstrates that the association between subjectively assigned values of anaesthetic depth and electroencephalographic parameters of anaesthetic depth is better for anaesthesiologists with more clinical experience. However, in the 'inexperienced' as well as 'experienced' group a high percentage of bispectral index and entropy values above 60 occurred despite a subjective assessment of adequate anaesthetic depth. Although there was no evidence for explicit memory, this may indicate a risk for memory formation.
引用
收藏
页码:292 / 299
页数:8
相关论文
共 39 条
  • [1] EXAGGERATED ANESTHETIC REQUIREMENTS IN THE PREFERENTIALLY ANESTHETIZED BRAIN
    ANTOGNINI, JF
    SCHWARTZ, K
    [J]. ANESTHESIOLOGY, 1993, 79 (06) : 1244 - 1249
  • [2] Manual versus target-controlled infusions of propofol
    Breslin, DS
    Mirakhur, RK
    Reid, JE
    Kyle, A
    [J]. ANAESTHESIA, 2004, 59 (11) : 1059 - 1063
  • [3] CLINICAL SIGNS OF ANESTHESIA
    CULLEN, DJ
    CROMWELL, TH
    CULLEN, BF
    FOURCADE, HE
    SMITH, NT
    STEVENS, WC
    STOELTING, RK
    BAHLMAN, SH
    EGER, EI
    DOLAN, WM
    GREGORY, GA
    [J]. ANESTHESIOLOGY, 1972, 36 (01) : 21 - +
  • [4] Unconscious auditory priming during surgery with propofol and nitrous oxide anaesthesia: a replication
    Deeprose, C
    Andrade, J
    Harrison, D
    Edwards, N
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (01) : 57 - 62
  • [5] Unconscious learning during surgery with propofol anaesthesia
    Deeprose, C
    Andrade, J
    Varma, S
    Edwards, N
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (02) : 171 - 177
  • [6] EGER EI, 1993, ANESTH ANALG, V77, P408
  • [7] MINIMUM ALVEOLAR ANESTHETIC CONCENTRATION - A STANDARD OF ANESTHETIC POTENCY
    EGER, EI
    SAIDMAN, LJ
    BRANDSTATER, B
    [J]. ANESTHESIOLOGY, 1965, 26 (6P1) : 756 - +
  • [8] Ellerkmann RK, 2004, ANESTHESIOLOGY, V101, P1275
  • [9] EVANS JM, 1987, LANCET, V330, P1033
  • [10] Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers
    Glass, PS
    Bloom, M
    Kearse, L
    Rosow, C
    Sebel, P
    Manberg, P
    [J]. ANESTHESIOLOGY, 1997, 86 (04) : 836 - 847