Micro-Computed Tomography and Scanning Electron Microscopy Comparisons of Two Nickel-Titanium Rotary Root Canal Instruments Used With Reciprocating Motion

被引:23
|
作者
Kim, Hee-Chul [1 ]
Hwang, You-Jeong [2 ]
Jung, Da-Woon [2 ]
You, Sung-Yeop [3 ,4 ]
Kim, Hyeon-Cheol [5 ]
Lee, WooCheol [3 ,4 ]
机构
[1] Korea Univ, Coll Med, Dept Chem, Seoul 136705, South Korea
[2] CHA Univ, CHA Bundang Med Ctr, Dept Dent, Songnam, South Korea
[3] Seoul Natl Univ, Sch Dent, Dept Conservat Dent, Seoul 110749, South Korea
[4] Seoul Natl Univ, Dent Res Inst, Seoul 110749, South Korea
[5] Pusan Natl Univ, Sch Dent, Dept Conservat Dent, Yangsan, South Korea
关键词
micro-computed tomography; reciprocating motion; apical transportation; single-file technique; microcrack; metallurgic property; F2 PROTAPER TECHNIQUE; CYCLIC FATIGUE LIFE; ENDODONTIC INSTRUMENTS; SHAPING ABILITY; ENGINE-DRIVEN; SHAPED CANALS; WAVEONE; RESISTANCE; MOVEMENT; SYSTEMS;
D O I
10.1002/sca.21039
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The single-file root canal instrumentation technique using reciprocating motion has been gaining concern. Therefore, the purpose of this study was to compare the shaping ability of single ProTaper F2 file and WaveOne Primary file when they were used in the curved root canal with reciprocation motion and to investigate the durability of the file after use with a scanning electron microscopy (SEM). Changes in structure model index (SMI), root canal volume, curvature, surface area, and degree of transportation were measured from the cross-sectional images of the prepared canals using the micro-CT system with an isotropic resolution of 16 m. Results showed that there were no differences in the changes of root canal volume, surface area, and SMI between the two file groups after the preparation (p > 0.05). The ProTaper group showed a curvature straightening value of 25.45 +/- 12.51%, while the WaveOne group showed 27.30 +/- 10.91%, and there was no statistically significant difference (p > 0.05). The transportation values between the two groups showed no significant differences (p > 0.05). SEM revealed that 60% of ProTaper files showed initiation of microcracks on the surface while those were detected on the only one WaveOne file. The single-file technique using either WaveOne Primary or ProTaper F2 can be safely used under each reciprocating motion without creating an increased apical transportation in curved canals. However, the metallurgic property resists cyclic fatigue was more favorable with WaveOne under the scanning evaluation. SCANNING 35: 112-118, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:112 / 118
页数:7
相关论文
共 50 条
  • [21] A comparison of the shaping ability of three nickel-titanium rotary instruments: a micro-computed tomography study via a contrast radiopaque technique in vitro
    Zhao Wei
    Zhi Cui
    Ping Yan
    Han Jiang
    BMC Oral Health, 17
  • [22] A comparison of the shaping ability of three nickel-titanium rotary instruments: a micro-computed tomography study via a contrast radiopaque technique in vitro
    Wei, Zhao
    Cui, Zhi
    Yan, Ping
    Jiang, Han
    BMC ORAL HEALTH, 2017, 17
  • [23] Comparison of Two Techniques for Assessing the Shaping Efficacy of Repeatedly Used Nickel-Titanium Rotary Instruments
    Ounsi, Hani F.
    Franciosi, Giovanni
    Paragliola, Raffaele
    Al Huzaimi, Khalid
    Salameh, Ziad
    Tay, Franklin R.
    Ferrari, Marco
    Grandini, Simone
    JOURNAL OF ENDODONTICS, 2011, 37 (06) : 847 - 850
  • [24] Shaping ability of rotary or reciprocating systems for oval root canal preparation: a micro-computed tomography study
    Camila Galletti Espir
    Camila Almeida Nascimento-Mendes
    Juliane Maria Guerreiro-Tanomaru
    Bruno Cavalini Cavenago
    Marco Antonio Hungaro Duarte
    Mário Tanomaru-Filho
    Clinical Oral Investigations, 2018, 22 : 3189 - 3194
  • [25] Microscopic computerized tomographic evaluation of root canal transportation prepared with twisted or ground nickel-titanium rotary instruments
    Freire, Laila Gonzales
    Gavini, Giulio
    Branco-Barletta, Fernando
    Sanches-Cunha, Rodrigo
    dos Santos, Marcelo
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (06): : E143 - E148
  • [26] Reciprocating Root Canal Technique Induces Greater Debris Accumulation Than a Continuous Rotary Technique as Assessed by 3-Dimensional Micro-Computed Tomography
    Robinson, Jonathan R.
    Lumley, Philip J.
    Cooper, Paul R.
    Grover, Liam M.
    Walmsley, A. Damien
    JOURNAL OF ENDODONTICS, 2013, 39 (08) : 1067 - 1070
  • [27] Shaping ability of two nickel–titanium instruments activated by continuous rotation or adaptive motion: a micro-computed tomography study
    E. Pedullà
    G. Plotino
    N. M. Grande
    G. Avarotti
    G. Gambarini
    E. Rapisarda
    F. Mannocci
    Clinical Oral Investigations, 2016, 20 : 2227 - 2233
  • [28] Analysis of second mesiobuccal root canal instrumentation in maxillary first molars with three nickel–titanium rotary instruments: a micro-computed tomographic study
    Yuerong Zhang
    Jie Liu
    Yongchun Gu
    Juan Wang
    Hai Xu
    Guangdong Zhang
    Odontology, 2021, 109 : 496 - 505
  • [29] Comparison of Canal Transportation and Changes in Canal Curvature of Two Nickel-Titanium Rotary Instruments
    El Batouty, Kariem M.
    Elmallah, Waleed E.
    JOURNAL OF ENDODONTICS, 2011, 37 (09) : 1290 - 1292
  • [30] Comparison of root canal preparation using reciprocating Safesiders stainless steel and Vortex nickel-titanium instruments
    Rhodes, S. Craig
    Huelsmann, Michael
    McNeal, Sandre F.
    Beck, Preston
    Eleazer, Paul D.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 111 (05): : 659 - 667