Seasonal Variation and Age-related Changes in the Relative Permittivity of Concrete Bridge Decks on Korea Expressways

被引:10
作者
Rhee, Ji-Young [1 ]
Kee, Seong-Hoon [2 ]
Kim, Hong-Sam [1 ]
Choi, Jae-Jin [3 ]
机构
[1] Korea Expressway Corp, Hwaseong, South Korea
[2] Dong A Univ, Dept Architectural Engn, Busan, South Korea
[3] Kongju Natl Univ, Dept Civil & Environm Engn, Kong Ju, South Korea
基金
新加坡国家研究基金会;
关键词
ground-penetrating radar; relative permittivity; concrete; seasonal variation; concrete age; deterioration; GROUND-PENETRATING RADAR; GPR; WATER;
D O I
10.1186/s40069-018-0239-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The purposes of this study were to investigate the seasonal variations in the relative permittivity of actual concrete bridge decks of various ages on Korea expressways, and to propose a practical way to calibrate two critical effects, to assess the condition of the concrete bridge decks with better accuracy. For these purposes, fifty-three actual concrete bridge decks on Korea expressways were scanned using an air-coupled ground penetrating radar (GPR) system, and the relative permittivity of the concrete was evaluated from the GPR data in the field. A statistical analysis showed that the relative permittivity of the concrete bridge decks in Korea are closely correlated with seasonal changes and concrete ages. For concrete bridge decks aged 10 years or older, the effect of concrete age was not as significant as that of relative humidity of the air on relative permittivity of concrete. Based on the results, a simple calibration process was proposed to suppress the effects of seasonal variation and age of concrete on the measured relative permittivity of the concrete decks on actual bridges. As will be discussed, the resulting relative permittivity method produced better agreement with the current condition of the concrete bridge decks as determined by visual inspection and other complementary methods (energy attenuation of GPR signals and corrosion potential measurements) than without the calibration process.
引用
收藏
页数:18
相关论文
共 30 条
  • [21] Rhee Jiyoung, 2017, [Journal of Korea Academia-Industrial cooperation Society, 한국산학기술학회논문지], V18, P209, DOI 10.5762/KAIS.2017.18.4.209
  • [22] Rhee Jiyoung, 2016, [Journal of The Korea Institute for Structural Maintenance and Inspection, 한국구조물진단유지관리공학회 논문집], V20, P84
  • [23] Electrical properties of water in clay and silty soils
    Saarenketo, T
    [J]. JOURNAL OF APPLIED GEOPHYSICS, 1998, 40 (1-3) : 73 - 88
  • [24] Suh J. W., 2000, ROAD ENG ASS AS AUST
  • [25] Suh J. W., 1998, 986765 KOR HIGHW COR
  • [26] Suh JW, 2004, RTST0403 KOR HIGHW R
  • [27] Condition assessment of concrete structures using a new analysis method: Ground-penetrating radar computer-assisted visual interpretation
    Tarussov, Alexander
    Vandry, Marc
    De La Haza, Aldo
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2013, 38 : 1246 - 1254
  • [28] The Ministry of Construction Division, 1984, 88 OL EXPR CONSTR MA
  • [29] Data acquisition and processing parameters for concrete bridge deck condition assessment using ground-coupled ground penetrating radar: Some considerations
    Varnavina, Aleksandra V.
    Khamzin, Aleksey K.
    Torgashov, Evgeniy V.
    Sneed, Lesley H.
    Goodwin, Brandon T.
    Anderson, Neil L.
    [J]. JOURNAL OF APPLIED GEOPHYSICS, 2015, 114 : 123 - 133
  • [30] Zhong Yanhui, 2012, 2012 14th International Conference on Ground Penetrating Radar (GPR), P403, DOI 10.1109/ICGPR.2012.6254899