Failure investigation of secondary super-heater tubes in a power boiler

被引:30
作者
Abou-elazm, A. Saad [1 ]
El Mahallawi, I. [1 ]
Abdel-karim, R. [1 ]
Rashad, R. [2 ]
机构
[1] Cairo Univ, Fac Engn, Dept Met, Giza 12613, Egypt
[2] Cairo Univ, Fac Engn, Dept Mech Engn, Giza 12613, Egypt
关键词
Failure; Stress corrosion cracking; Sensitization; Super-heater tubes; Boiler; STRESS-CORROSION CRACKING;
D O I
10.1016/j.engfailanal.2008.06.024
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
I his study investigates a failure case in El-Kureimat thermal power station unit number 2 which experienced secondary super-heater tube failures. The failed tubes were reportedly found to be weeping during an operating pressure hydrostatic test, performed after a repair of another boiler component. The failure analysis indicated that the 304H tube leakage was due to stress corrosion cracking. The cracked tubes were studied and found to have undergone sensitization due to either welding or heat treatment of bent parts. Both service-exposed and laboratory specimens were studied in the current work. The service exposed samples that exhibited cracking were removed from the foresaid boiler. The laboratory specimens were used to verify proposed failure sequence and to evaluate the susceptibility of this alloy to sensitization. A correlation was made between artificially sensitized samples and stress corrosion cracking mechanism. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:433 / 448
页数:16
相关论文
共 15 条
[1]  
[Anonymous], ANN BOOK ASTM STAND
[2]  
*ASTM, ANN BOOK ASTM
[3]  
CRAIG B, SPECIALTY HDB ASM, V13
[4]  
DAVIS JR, 1996, SPECIALTY HDB ASM
[5]  
GOUDA VK, 1981, BRIT CORROS J, V16, P25
[6]  
KINA AY, 2007, MICROSTRUCTURE INTER
[7]  
LOGAN HL, 1990, STRESS CORROSION NAC
[8]   MICROSTRUCTURAL CHANGES IN AUSTENITIC STAINLESS-STEELS DURING LONG-TERM AGING [J].
MINAMI, Y ;
KIMURA, H ;
IHARA, Y .
MATERIALS SCIENCE AND TECHNOLOGY, 1986, 2 (08) :795-806
[9]   Comparative study: Degree of sensitization and intergranular stress corrosion cracking susceptibility of type 304 stainless steel [J].
Muraleedharan, P ;
Gnanamoorthy, JB ;
Rodriguez, P .
CORROSION, 1996, 52 (10) :790-800
[10]   Stress corrosion cracking of sensitized type 304 stainless steel in hydrochloric acid solution - Predicting time-to-failure and effect of sensitizing temperature [J].
Nishimura, R ;
Katim, I ;
Maeda, Y .
CORROSION, 2001, 57 (10) :853-862