Kretschmann based Surface Plasmon Resonance for Sensing in Visible Region

被引:16
|
作者
Menon, P. S. [1 ]
Gan, S. M. [1 ]
Mohamad, N. R. [1 ]
Jamil, N. A. [1 ]
Tarumaraja, K. A. [1 ]
Razak, N. R. [2 ]
Bakar, A. A. A. [3 ]
Mukhtar, W. M. [4 ]
Murat, N. F. [4 ]
Mohamed, R. [5 ]
Khairulazdan, N. B. [5 ]
Said, F. A. [1 ]
机构
[1] UKM, Inst Microengn & Nanoelect IMEN, Bangi, Malaysia
[2] UKM, Pusat PermataPINTAR Negara, Bangi, Malaysia
[3] Univ Kebangsaan Malaysia UKM, Ctr Adv Elect & Commun Engn, Fac Engn & Built Environm, Ukm Bangi 43600, Selangor, Malaysia
[4] Univ Sains Islam Malaysia USIM, Fac Sci & Technol, Nilai, Negeri Sembilan, Malaysia
[5] Univ Teknol MARA UiTM, Fac Appl Sci, Bandar Jengka 26400, Pahang, Malaysia
关键词
surface plasmon resonance (SPR); Kretschmann; sensor; visible wavelength; metal oxide; conducting metal oxides (TMO); graphene; graphene oxide; transition metal dichalcogenide (TMD); SPR; DESIGN; OPTIMIZATION; SENSITIVITY; SIMULATION; SENSOR; UREA;
D O I
10.1109/inec.2019.8853847
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Kretschmann-based surface plasmon resonance (K-SPR) sensing approach using planar thin metal films offer distinct advantages over other label-free sensing techniques in the visible region. SPR phenomenon occurs due to the propagation of electromagnetic waves along the surface of the thin metal layers. Practically, some refractive index changes on the dielectric sample layer will cause changes in surface plasmon polaritons (SPP). The main purpose of using this coupling technique is to match the light-wave vector wave with the SPP vector wave. This paper will give an overview of the design and development of SPR-based sensors utilizing the angular interrogation Kretschmann configuration for detecting the presence of various analytes such as urea, creatinine, glucose, ethanol and uric acid in the visible region. Various sensor layers such as 50-nm thick gold (Au), MoS2/graphene, Au/graphene oxide, Ag/ITO and Au/Ag/ZnO thin films were used to detect the analytes at 633 nm, 670 nm and 785 nm visible electromagnetic wavelengths. Output characteristics such as the reflectivity, full width at half maximum (FWHM), sensitivity, Q factor and Figure of merit (FOM) of the sensors were analyzed. Results of this study was obtained using Lumerical's Finite Difference Time Domain (FDTD) and experimental characterization was obtained using Bionavis SPR equipment; available at IMEN, UKM.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] MXene-Based Kretschmann Configured Surface Plasmon Resonance Sensor in Visible Regime
    Zhao, Liping
    Wu, Degang
    Chen, Qianhui
    PLASMONICS, 2024, 19 (03) : 1679 - 1685
  • [2] Surface plasmon resonance in the visible region in sensors based on tapered optical fibers
    Navarrete, Maria-Cruz
    Diaz-Herrera, Natalia
    Gonzalez-Cano, Agustin
    Esteban, Oscar
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 881 - 885
  • [3] Spectral and Angular Responses of Surface Plasmon Resonance Based on the Kretschmann Prism Configuration
    Gwon, Hyuk Rok
    Lee, Seong Hyuk
    MATERIALS TRANSACTIONS, 2010, 51 (06) : 1150 - 1155
  • [4] SIMULATION OF HEMOGLOBIN DETECTION USING SURFACE PLASMON RESONANCE BASED ON KRETSCHMANN CONFIGURATION
    Sumantri, Roni
    Hasanah, Lilik
    Arifin, Mohammad
    Tayubi, Yuyu Rachmat
    Wulandari, Chandra
    Rusdiana, Dadi
    Julian, Cahya
    Pawinanto, Roer Eka
    Menon, P. Susthita
    Sahari, Siti Kudnie
    Mulyanti, Budi
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2020, 15 (04): : 2239 - 2247
  • [5] Simulation of absorption-based surface plasmon resonance sensor in the Kretschmann configuration
    Fekete, Adam
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2013, 41 (06) : 646 - 652
  • [6] Optimization of Kretschmann based on Surface Plasmon Resonance Sensor using Taguchi Method
    Mei, Gan Siew
    Mohamad, Najmiah Radiah Binti
    Jamil, Nur Akmar Binti
    Majlis, Burhanuddin Yeop
    Menon, P. Susthitha
    SAINS MALAYSIANA, 2018, 47 (10): : 2565 - 2571
  • [7] Surface Plasmon Resonance Sensor Based on Kretschmann Configuration for Dengue Virus Detection
    Aprilia, Lia
    Mayasari, Rina Dewi
    Yanza, Nabella
    Pambudi, Sabar
    Tarwadi
    Budi, Agus Setyo
    Nuryadi, Ratno
    2022 INTERNATIONAL CONFERENCE ON RADAR, ANTENNA, MICROWAVE, ELECTRONICS, AND TELECOMMUNICATIONS (ICRAMET): EMERGING SCIENCE AND INDUSTRIAL INNOVATION IN ELECTRONICS AND TELECOMMUNICATION, 2022, : 175 - 178
  • [8] Surface Plasmon Resonance-Based Protein Bio-Sensing Using a Kretschmann Configured Double Prism Arrangement
    Boruah, Ratan
    Mohanta, Dambarudhar
    Choudhury, Amarjyoti
    Nath, Pabitra
    Ahmed, Gazi Ameen
    IEEE SENSORS JOURNAL, 2015, 15 (12) : 6791 - 6796
  • [9] Effect of Light Source on Kretschmann Surface Plasmon Resonance Sensor
    Gong, Chaoyang
    Gao, Hongyun
    Hua, Li
    Li, Min
    FOURTH ASIA PACIFIC OPTICAL SENSORS CONFERENCE, 2013, 8924
  • [10] Phenylalanine Sensing Based on Surface Plasmon Resonance
    Chen, Hongxia
    Lee, Jaebeom
    Kim, Sung-Hoon
    Kim, Jae-Ho
    Koh, Kwangnak
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2009, 9 (12) : 7199 - 7203