Impedimetric array in polymer microfluidic cartridge for low cost point-of-care diagnostics

被引:41
作者
Lakey, Andrew [1 ]
Ali, Zulfiqur [1 ]
Scott, Simon M. [1 ]
Chebil, Syrine [2 ]
Korri-Youssoufi, Hafsa [2 ]
Hunor, Santha [3 ]
Ohlander, Anna [4 ]
Kuphal, Mathias [5 ]
Samitier Marti, Josep [5 ]
机构
[1] Teesside Univ, Healthcare Innovat Ctr, Middlesbrough TS1 3BX, Tees Valley, England
[2] Univ Paris Saclay, ECBB, ICMMO, UMR 8182,CNRS,Univ Paris Sud, F-91405 Orsay, France
[3] Budapest Univ Technol & Econ, Dept Elect Technol, Budapest, Hungary
[4] Fraunhofer EMFT, Inst Microsyst & Solid State Technol, Munich, Germany
[5] Barcelona Inst Sci & Technol, IBEC Inst Bioengn Catalonia, Barcelona, Spain
基金
英国工程与自然科学研究理事会;
关键词
Impedimetric sensing; Electropolymerisation; Interdigitated electrodes; Point-of-care diagnostics; Microfluidics; DEEP-VEIN THROMBOSIS; D-DIMER; PULMONARY-EMBOLISM; SELECTIVE IMMUNOSENSOR; BIOSENSOR; GOLD; THROMBOEMBOLISM; NANOPARTICLES; NANOTUBES; ASSAY;
D O I
10.1016/j.bios.2018.12.054
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Deep Vein Thrombosis and pulmonary embolism (DVT/PE) is one of the most common causes of unexpected death for hospital in-patients. D-dimer is used as a biomarker within blood for the diagnosis of DVT/PE. We report a low-cost microfluidic device with a conveniently biofunctionalised interdigitated electrode (IDE) array and a portable impedimetric reader as a point-of-care (POC) device for the detection of D-dimer to aid diagnosis of DVT/PE. The IDE array elements, fabricated on a polyethylenenaphtalate (PEN) substrate, are biofunctionalised in situ after assembly of the microfluidic device by electropolymerisation of a copolymer of polypyrrole to which is immobilised a histidine tag anti-D-Dimer antibody. The most consistent copolymer films were produced using chronopotentiometry with an applied current of 5 mu A for a period of 50 s using a two-electrode system. The quality of the biofunctionalisation was monitored using optical microscopy, chronopotentiometry curves and impedimetric analysis. Measurement of clinical plasma sample with a D-dimer at concentration of 437 ng/mL with 15 biofunctionalised IDE array electrodes gave a ratiometric percentage of sample reading against the blank with an average value of 124 +/- 15 at 95% confidence. We have demonstrated the concept of a low cost disposable microfluidic device with a receptor functionalised on the IDE array for impedimetric detection towards POC diagnostics. Changing the receptor on the IDE array would allow this approach to be used for the direct detection of a wide range of analytes in a low cost manner.
引用
收藏
页码:147 / 154
页数:8
相关论文
共 30 条
[11]   Validation of a new D-dimer microparticle enzyme immunoassay (AxSYM D-Dimer) in patients with suspected pulmonary embolism (PE) [J].
Ghanima, W. ;
Sandset, P. M. .
THROMBOSIS RESEARCH, 2007, 120 (04) :471-476
[12]   Effect of electrical conditions on an impedimetric immunosensor based on a modified conducting polypyrrole [J].
Hafaid, Imen ;
Chebil, Syrine ;
Korri-Youssoufi, Hafsa ;
Bessueille, Francois ;
Errachid, Abdelhamid ;
Sassi, Zina ;
Ali, Zulfiqur ;
Abdelghani, Adnane ;
Jaffrezic-Renault, Nicole .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 144 (01) :323-331
[13]   A potentiometric immunosensor based on silver nanoparticles decorated ZnO nanotubes, for the selective detection of d-dimer [J].
Ibupoto, Z. H. ;
Jamal, N. ;
Khun, K. ;
Liu, X. ;
Willander, M. .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 182 :104-111
[14]   The Development of Highly Sensitive and Selective Immunosensor Based on Antibody Immobilized ZnO Nanorods for the Detection of D-Dimer [J].
Ibupoto, Zafar H. ;
Mitrou, Nikolaos ;
Nikoleli, Georgia-Paraskevi ;
Nikolelis, Dimitrios P. ;
Willander, Magnus ;
Psaroudakis, Nikolas .
ELECTROANALYSIS, 2014, 26 (02) :292-298
[15]   Conductometric microbiosensors for environmental monitoring [J].
Jaffrezic-Renault, Nicole ;
Dzyadevych, Sergei V. .
SENSORS, 2008, 8 (04) :2569-2588
[16]   Comparison of the performances of conductometric microsensors for different technologies and designs of interdigitated electrodes [J].
Khadro, Basma ;
Santha, Hunor ;
Nagy, Peter ;
Harsanyi, Gabor ;
Jaffrezic-Renault, Nicole .
SENSOR LETTERS, 2008, 6 (03) :413-416
[17]   Electrochemical probing of DNA based on oligonucleotide-functionalized polypyrrole [J].
Korri-Youssoufi, H ;
Yassar, A .
BIOMACROMOLECULES, 2001, 2 (01) :58-64
[18]   Polymer-based technology platform for robust electrochemical sensing using gold microelectrodes [J].
Kuphal, M. ;
Mills, C. A. ;
Korri-Youssoufi, H. ;
Samitier, J. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01) :279-284
[19]  
Lopez Jose A, 2004, Hematology Am Soc Hematol Educ Program, P439
[20]   A novel proteinase K biosensor based on interdigitated conductometric electrodes for proteins determination in rivers and sewers water [J].
Marrakchi, M ;
Dzyadevych, SV ;
Namour, P ;
Martelet, C ;
Jaffrezic-Renaulta, N .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 :390-395