Improving diffusion MRI using simultaneous multi-slice echo planar imaging

被引:273
作者
Setsompop, K. [1 ,2 ]
Cohen-Adad, J. [1 ,2 ]
Gagoski, B. A. [3 ]
Raij, T. [1 ,2 ]
Yendiki, A. [1 ,2 ]
Keil, B. [1 ,2 ]
Wedeen, V. J. [1 ,2 ]
Wald, L. L. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Dept Radiol, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
关键词
Diffusion MRI; Simultaneous multi-slice; CAIPIRINHA; Parallel imaging; SPIN-ECHO; SELECTIVE EXCITATION; FIBER ORIENTATION; TENSOR MRI; IMAGES; GRADIENT; EPI; RECONSTRUCTIONS; ARRAYS; SIGNAL;
D O I
10.1016/j.neuroimage.2012.06.033
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In diffusion MRI, simultaneous multi-slice single-shot EPI acquisitions have the potential to increase the number of diffusion directions obtained per unit time, allowing more diffusion encoding in high angular resolution diffusion imaging (HARDI) acquisitions. Nonetheless, unaliasing simultaneously acquired, closely spaced slices with parallel imaging methods can be difficult, leading to high g-factor penalties (i.e., lower SNR). The CAIPIRINHA technique was developed to reduce the g-factor in simultaneous multi-slice acquisitions by introducing interslice image shifts and thus increase the distance between aliased voxels. Because the CAIPIRINHA technique achieved this by controlling the phase of the RF excitations for each line of k-space, it is not directly applicable to single-shot EPI employed in conventional diffusion imaging. We adopt a recent gradient encoding method, which we termed "blipped-CAIPI", to create the image shifts needed to apply CAIPIRINHA to EPI. Here, we use pseudo-multiple replica SNR and bootstrapping metrics to assess the performance of the blipped-CAIPI method in 3 x simultaneous multi-slice diffusion studies. Further, we introduce a novel image reconstruction method to reduce detrimental ghosting artifacts in these acquisitions. We show that data acquisition times for Q-ball and diffusion spectrum imaging (DSI) can be reduced 3-fold with a minor loss in SNR and with similar diffusion results compared to conventional acquisitions. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:569 / 580
页数:12
相关论文
共 50 条
  • [41] Using multi-echo simultaneous multi-slice (SMS) EPI to improve functional MRI of the subcortical nuclei of the basal ganglia at ultra-high field (7T)
    Puckett, Alexander M.
    Bollmann, Saskia
    Poser, Benedikt A.
    Palmer, Jake
    Barth, Markus
    Cunnington, Ross
    NEUROIMAGE, 2018, 172 : 886 - 895
  • [42] High-Resolution Simultaneous Multi-Slice Accelerated Turbo Spin-Echo Musculoskeletal Imaging: A Head-to-Head Comparison With Routine Turbo Spin-Echo Imaging
    Gao, Feifei
    Wen, Zejun
    Dou, Shewei
    Kan, Xiaojing
    Wei, Shufang
    Ge, Yinghui
    FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [43] Simultaneous multi-slice accelerated 4D-MRI for radiotherapy guidance
    Keijnemans, K.
    Borman, P. T. S.
    van Lier, A. L. H. M. W.
    Verhoeff, J. J. C.
    Raaymakers, B. W.
    Fast, M. F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (09)
  • [44] MR susceptibility contrast imaging using a 2D simultaneous multi-slice gradient-echo sequence at 7T
    Bian, Wei
    Kerr, Adam B.
    Tranvinh, Eric
    Parivash, Sherveen
    Zahneisen, Benjamin
    Han, May H.
    Lock, Christopher B.
    Goubran, Maged
    Zhu, Kongrong
    Rutt, Brian K.
    Zeineh, Michael M.
    PLOS ONE, 2019, 14 (07):
  • [45] Acoustic Noise Reduction of Echo Planar Imaging in Diffusion MRI
    Zhao, Junwei
    Lin, Zhenliang
    Zhou, Xiaodong
    Li, Guobin
    Luo, Jie
    ICBBE 2019: 2019 6TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND BIOINFORMATICS ENGINEERING, 2019, : 33 - 38
  • [46] An optimization framework to maximize signal-to-noise ratio in simultaneous multi-slice body imaging
    Stemkens, Bjorn
    Sbrizzi, Alessandro
    Andreychenko, Anna A.
    Crijns, Sjoerd P. M.
    Lagendijk, Jan J. W.
    van den Berg, Cornelis A. T.
    Tijssen, Rob H. N.
    NMR IN BIOMEDICINE, 2016, 29 (03) : 275 - 283
  • [47] Radial simultaneous multi-slice CAIPI for ungated myocardial perfusion
    Wang, Haonan
    Adluru, Ganesh
    Chen, Liyong
    Kholmovski, Eugene G.
    Bangerter, Neal K.
    DiBella, Edward V. R.
    MAGNETIC RESONANCE IMAGING, 2016, 34 (09) : 1329 - 1336
  • [48] Ultrafast fMRI of the rodent brain using simultaneous multi-slice EPI
    Lee, Hsu-Lei
    Li, Zengmin
    Coulson, Elizabeth J.
    Chuang, Kai-Hsiang
    NEUROIMAGE, 2019, 195 : 48 - 58
  • [49] Simultaneous multi-slice spin- and gradient-echo dynamic susceptibility-contrast perfusion-weighted MRI of gliomas
    Han, Misung
    Yang, Baolian
    Fernandez, Brice
    Lafontaine, Marisa
    Alcaide-Leon, Paula
    Jakary, Angela
    Burns, Brian L.
    Morrison, Melanie A.
    Villanueva-Meyer, Javier E.
    Chang, Susan M.
    Banerjee, Suchandrima
    Lupo, Janine M.
    NMR IN BIOMEDICINE, 2021, 34 (01)
  • [50] Comparison of multi-echo spiral and echo planar imaging in functional MRI
    Klarhöfer, M
    Barth, M
    Moser, E
    MAGNETIC RESONANCE IMAGING, 2002, 20 (04) : 359 - 364