RETRACTED: A robust technique based on VLM and Frangi filter for retinal vessel extraction and denoising (Retracted Article)

被引:30
作者
Khan, Khan Bahadar [1 ,2 ,4 ]
Khaliq, Amir. A. [2 ]
Jalil, Abdul [2 ]
Shahid, Muhammad [3 ]
机构
[1] Islamia Univ Bahawalpur, Dept Telecommun Engn, Bahawalpur, Pakistan
[2] Int Islamic Univ, Dept Elect Engn, Islamabad, Pakistan
[3] Al Khawarizmi Inst Comp Sci, Uet Lahore, Pakistan
[4] Int Islamic Univ, Dept Elect Engn, Fac Engn & Technol, Islamabad, Pakistan
来源
PLOS ONE | 2018年 / 13卷 / 02期
关键词
ADAPTIVE HISTOGRAM EQUALIZATION; BLOOD-VESSELS; SEGMENTATION; IMAGES;
D O I
10.1371/journal.pone.0192203
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The exploration of retinal vessel structure is colossally important on account of numerous diseases including stroke, Diabetic Retinopathy (DR) and coronary heart diseases, which can damage the retinal vessel structure. The retinal vascular network is very hard to be extracted due to its spreading and diminishing geometry and contrast variation in an image. The proposed technique consists of unique parallel processes for denoising and extraction of blood vessels in retinal images. In the preprocessing section, an adaptive histogram equalization enhances dissimilarity between the vessels and the background and morphological top-hat filters are employed to eliminate macula and optic disc, etc. To remove local noise, the difference of images is computed from the top-hat filtered image and the high-boost filtered image. Frangi filter is applied at multi scale for the enhancement of vessels possessing diverse widths. Segmentation is performed by using improved Otsu thresholding on the high-boost filtered image and Frangi's enhanced image, separately. In the post-processing steps, a Vessel Location Map (VLM) is extracted by using raster to vector transformation. Postprocessing steps are employed in a novel way to reject misclassified vessel pixels. The final segmented image is obtained by using pixel-by-pixel AND operation between VLM and Frangi output image. The method has been rigorously analyzed on the STARE, DRIVE and HRF datasets.
引用
收藏
页数:22
相关论文
共 48 条
[1]   An Automatic Cognitive Graph-Based Segmentation for Detection of Blood Vessels in Retinal Images [J].
Al Shehhi, Rasha ;
Marpu, Prashanth Reddy ;
Woon, Wei Lee .
MATHEMATICAL PROBLEMS IN ENGINEERING, 2016, 2016
[2]   An Active Contour Model for Segmenting and Measuring Retinal Vessels [J].
Al-Diri, Bashir ;
Hunter, Andrew ;
Steel, David .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (09) :1488-1497
[3]   Trainable COSFIRE filters for vessel delineation with application to retinal images [J].
Azzopardi, George ;
Strisciuglio, Nicola ;
Vento, Mario ;
Petkov, Nicolai .
MEDICAL IMAGE ANALYSIS, 2015, 19 (01) :46-57
[4]   Fast Retinal Vessel Detection and Measurement Using Wavelets and Edge Location Refinement [J].
Bankhead, Peter ;
Scholfield, C. Norman ;
McGeown, J. Graham ;
Curtis, Tim M. .
PLOS ONE, 2012, 7 (03)
[5]   Digital Ocular Fundus Imaging: A Review [J].
Bernardes, Rui ;
Serranho, Pedro ;
Lobo, Conceicao .
OPHTHALMOLOGICA, 2011, 226 (04) :161-181
[6]   Emerging trends in ocular telemedicine: the diabetic retinopathy model [J].
Cavallerano, J ;
Aiello, LM .
JOURNAL OF TELEMEDICINE AND TELECARE, 2005, 11 (04) :163-166
[7]   DETECTION OF BLOOD-VESSELS IN RETINAL IMAGES USING TWO-DIMENSIONAL MATCHED-FILTERS [J].
CHAUDHURI, S ;
CHATTERJEE, S ;
KATZ, N ;
NELSON, M ;
GOLDBAUM, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1989, 8 (03) :263-269
[8]   Modified two-dimensional Otsu image segmentation algorithm and fast realisation [J].
Chen, Q. ;
Zhao, L. ;
Lu, J. ;
Kuang, G. ;
Wang, N. ;
Jiang, Y. .
IET IMAGE PROCESSING, 2012, 6 (04) :426-433
[9]   A New Approach to Segment Both Main and Peripheral Retinal Vessels Based on Gray-Voting and Gaussian Mixture Model [J].
Dai, Peishan ;
Luo, Hanyuan ;
Sheng, Hanwei ;
Zhao, Yali ;
Li, Ling ;
Wu, Jing ;
Zhao, Yuqian ;
Suzuki, Kenji .
PLOS ONE, 2015, 10 (06)
[10]  
Erdt M., 2012, J RAD ONCOLOGY INFOR, V4, P1, DOI DOI 10.3933/JR0I-4-1-19