A source model for efficient brachytherapy computations with Monte Carlo

被引:7
作者
Weaver, K [1 ]
Siantar, CH [1 ]
Chandler, W [1 ]
White, RM [1 ]
机构
[1] LAWRENCE LIVERMORE NATL LAB,PHYS & SPACE TECHNOL DIRECTORATE,LIVERMORE,CA 94550
关键词
brachytherapy; Monte Carlo; source model; anisotropy;
D O I
10.1118/1.597890
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Monte Carlo techniques have the potential for producing accurate brachytherapy dose distributions in heterogeneous finite geometries. However, for routine clinical use, computational speed must be adequate. fast, all-particle, CT-based Monte Carlo code called PEREGRINE is being developed at Lawrence Livermore National Laboratory for radiation treatment planning. As one feature, the code will produce accurate dose distributions from brachytherapy sources in heterogeneous geometries. For efficiency, brachytherapy sources in this model are treated as points or line segments. Radiation is emitted with the proper energy spectrum and (perhaps anisotropic) angular distribution. In particular, for anisotropic emission the polar angle is determined by a random-number driven empirical function constructed from a source's measured or precomputed fluence emission pattern. Source model parameters are presented for iodine and iridium sources. While designed for the PEREGRINE program, this source model can be used in any Monte Carlo code. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:2079 / 2084
页数:6
相关论文
共 17 条
[1]  
Browne E., 1986, Table of Radioactive Isotopes
[2]   TWO-DIMENSIONAL DOSE DISTRIBUTION AROUND A COMMERCIAL I125 SEED [J].
BURNS, GS ;
RAESIDE, DE .
MEDICAL PHYSICS, 1988, 15 (01) :56-60
[3]  
KUBIATOWICZ D, 1983, COMMUNICATION
[4]  
LING C, 1985, MED PHYS, V182, P652
[5]   PHYSICAL DOSIMETRY OF I-125 SEEDS OF A NEW DESIGN FOR INTERSTITIAL IMPLANT [J].
LING, CC ;
YORKE, ED ;
SPIRO, IJ ;
KUBIATOWICZ, D ;
BENNETT, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (11) :1747-1752
[6]   COMPARISON OF RADIATION-DOSIMETRY IN WATER AND IN SOLID PHANTOM MATERIALS FOR I-125 AND PD-103 BRACHYTHERAPY SOURCES - EGS4 MONTE-CARLO STUDY [J].
LUXTON, G .
MEDICAL PHYSICS, 1994, 21 (05) :631-641
[7]   TISSUE INHOMOGENEITY CORRECTION FOR BRACHYTHERAPY SOURCES IN A HETEROGENEOUS PHANTOM WITH CYLINDRICAL SYMMETRY [J].
MEIGOONI, AS ;
NATH, R .
MEDICAL PHYSICS, 1992, 19 (02) :401-407
[8]   ANISOTROPY FUNCTIONS FOR PD-103, I-125, AND IR-192 INTERSTITIAL BRACHYTHERAPY SOURCES [J].
NATH, R ;
MEIGOONI, AS ;
MUENCH, P ;
MELILLO, A .
MEDICAL PHYSICS, 1993, 20 (05) :1465-1473
[9]   DOSIMETRY OF INTERSTITIAL BRACHYTHERAPY SOURCES - RECOMMENDATIONS OF THE AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO 43 [J].
NATH, R ;
ANDERSON, LL ;
LUXTON, G ;
WEAVER, KA ;
WILLIAMSON, JF ;
MEIGOONI, AS .
MEDICAL PHYSICS, 1995, 22 (02) :209-234
[10]  
Nelson W.R., 1985, EGS4 CODE SYSTEM