The effect of physiological noise in phase functional magnetic resonance imaging:: from blood oxygen level-dependent effects to direct detection of neuronal currents

被引:29
作者
Hagberg, Gisela E. [1 ]
Bianciardi, Marta [1 ,5 ]
Brainovich, Valentina [1 ]
Cassara, Antonino Mario [2 ,3 ,4 ]
Maraviglia, Bruno [2 ,3 ,4 ]
机构
[1] Fdn Santa Lucia IRCCS, Lab Neuroimaging, I-00179 Rome, Italy
[2] Univ Roma La Sapienza, Dept Phys, I-00185 Rome, Italy
[3] Museo Storico Fis, I-00184 Rome, Italy
[4] Ctr Studi & Ric, I-00184 Rome, Italy
[5] NINDS, Adv MRI Sect, NIH, Bethesda, MD 20892 USA
关键词
fMRI; phase; physiological noise; BOLD; nc-MRI; human; brain;
D O I
10.1016/j.mri.2008.01.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, the possibility to use both magnitude and phase image sets for the statistical evaluation of fMRI has been proposed, with the prospective of increasing both statistical power and the spatial specificity. In the present work, several issues that affect the spatial and temporal stability in fMRI phase time series in the presence of physiologic noise processes are reviewed, discussed and illustrated by experiments performed at 3 T. The observed phase value is a fingerprint of the underlying voxel averaged magnetic field variations. Those related to physiological processes can be considered static or dynamic in relation to the temporal scale of a 2D acquisition and will play out on different spatial scales as well: globally across the entire images slice, and locally depending on the constituents and their relative fractions inside the MRI voxel. The 'static' respiration-induced effects lead to magneto-mechanic scan-to-scan variations in the global magnetic field but may also contribute to local BOLD fluctuations due to respiration-related variations in arterial carbon dioxide. Likewise, the 'dynamic' cardiac-related effects will lead to global susceptibility effects caused by pulsatile motion of the brain as well as local blood pressure-related changes in BOLD and changes in blood flow velocity. Finally, subject motion may lead to variations in both local and global tissue susceptibility that will be especially pronounced close to air cavities. Since dissimilar manifestations of physiological processes can be expected in phase and in magnitude images, a direct relationship between phase and magnitude scan-to-scan fluctuations cannot be assumed a priori. Therefore three different models were defined for the phase stability, each dependent on the relation between phase and magnitude variations and the best will depend on the underlying noise processes. By experiments on healthy volunteers at rest, we showed that phase stability depends on the type of post-processing and can be improved by reducing the low-frequency respiration-induced mechano-magnetic effects. Although the manifestations of physiological noise were in general more pronounced in phase than in magnitude images, due to phase wraps and global Bo effects, we Suggest that a phase stability similar to that found in magnitude could theoretically be achieved by adequate correction methods. Moreover, as suggested by out-experimental data regarding BOLD-related phase effects, phase stability could even supersede magnitude stability in voxels covering dense microvascular networks with BOLD-related fluctuations as the dominant noise contributor. In the interest of the quality of both BOLD-based and nc-MRI methods, future studies are required to find alternative methods that can improve phase stability, designed to match the temporal and spatial scale of the underlying neuronal activity. (c) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:1026 / 1040
页数:15
相关论文
共 40 条
[1]   How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging [J].
Andersson, JLR ;
Skare, S ;
Ashburner, J .
NEUROIMAGE, 2003, 20 (02) :870-888
[2]   Direct detection of neuronal activity with MRI: Fantasy, possibility, or reality? [J].
Bandettini, PA ;
Petridou, N ;
Bodurka, J .
APPLIED MAGNETIC RESONANCE, 2005, 29 (01) :65-88
[3]   Combination of BOLD-fMRI and VEP recordings for spin-echo MRI detection of primary magnetic effects caused by neuronal currents [J].
Bianciardi, M ;
Di Russo, F ;
Aprile, T ;
Maraviglia, B ;
Hagberg, GE .
MAGNETIC RESONANCE IMAGING, 2004, 22 (10) :1429-1440
[4]   Separating respiratory-variation-related neuronal-activity-related fluctuations in fluctuations from fMRI [J].
Birn, RM ;
Diamond, JB ;
Smith, MA ;
Bandettini, PA .
NEUROIMAGE, 2006, 31 (04) :1536-1548
[5]   Modelling the magnetic signature of neuronal tissue [J].
Blagoev, K. B. ;
Mihaila, B. ;
Travis, B. J. ;
Alexandrov, L. B. ;
Bishop, A. R. ;
Ranken, D. ;
Posse, S. ;
Gasparovic, C. ;
Mayer, A. ;
Aine, C. J. ;
Ulbert, I. ;
Morita, M. ;
Muller, W. ;
Connor, J. ;
Halgren, E. .
NEUROIMAGE, 2007, 37 (01) :137-148
[6]  
BODURKA J, 2005, P INT SOC MAG RESON, V13, P1554
[7]   Optimal measurement of magnitude and phase from MR data [J].
Bonny, JM ;
Renou, JP ;
Zanca, M .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 113 (02) :136-144
[8]   Realistic simulations of neuronal activity: A contribution to the debate on direct detection of neuronal currents by MRI [J].
Cassara, A. M. ;
Hagberg, G. E. ;
Bianciardi, M. ;
Migliore, M. ;
Maraviglia, B. .
NEUROIMAGE, 2008, 39 (01) :87-106
[9]   Numerical calculations of the static magnetic field in three-dimensional multi-tissue models of the human head [J].
Collins, CM ;
Yang, B ;
Yang, QX ;
Smith, MB .
MAGNETIC RESONANCE IMAGING, 2002, 20 (05) :413-424
[10]   New robust 3-D phase unwrapping algorithms: Application to magnetic field mapping and undistorting echoplanar images [J].
Cusack, R ;
Papadakis, N .
NEUROIMAGE, 2002, 16 (03) :754-764