Synthetic single crystal diamond diodes for radiotherapy dosimetry

被引:40
作者
Almaviva, S. [1 ]
Marinelli, Marco [1 ]
Milani, E. [1 ]
Tucciarone, A. [1 ]
Verona-Rinati, G. [1 ]
Consorti, R. [2 ]
Petrucci, A. [2 ]
De Notaristefani, F. [3 ]
Ciancaglioni, I.
机构
[1] Univ Roma Tor Vergata, Ist Nazl Fis Nucl, Dipartimento Ingn Meccan, I-00133 Rome, Italy
[2] Osped San Filippo Neri, UO Fis Sanit, I-00135 Rome, Italy
[3] Univ Roma 3, Ist Nazl Fis Nucl, Dipartimento Ingn Elettron, I-00146 Rome, Italy
关键词
single crystal diamond; radiotherapy dosimeter;
D O I
10.1016/j.nima.2008.06.028
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Synthetic single crystal diamonds in a p-type/intrinsic/metal structure were tested as dosimeters for radiotherapy. The devices have been analyzed by using 6 and 10MV Bremsstrahlung X-ray beams and electron beams from 6 MeV up to 18 MeV from a CLINAC DHX Varian accelerator. All measurements have been performed in a water phantom and ionization chambers were used for calibration and comparison. The dosimeters were operated in photovoltaic regime with no external bias voltage applied. A few Gy pre-irradiation was performed in order to stabilize the device output, resulting in fluctuations sensitivity below +/-0.5%. No dose rate dependence of the detector response was observed. Very good reproducibility and linearity were obtained as well. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:273 / 277
页数:5
相关论文
共 13 条
[1]   Diamond dosimetry: Outcomes of the CANDIDO and CONRAD INFN projects [J].
Bucciolini, M ;
Borchi, E ;
Bruzzi, M ;
Casati, M ;
Cirrone, P ;
Cuttone, G ;
De Angelis, C ;
Lovik, I ;
Onori, S ;
Raffaele, L ;
Sciortino, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 552 (1-2) :189-196
[2]   An investigation of the operating characteristics of two PTW diamond detectors in photon and electron beams [J].
De Angelis, C ;
Onori, S ;
Pacilio, M ;
Cirrone, GAP ;
Cuttone, G ;
Raffaele, L ;
Bucciolini, M ;
Mazzocchi, S .
MEDICAL PHYSICS, 2002, 29 (02) :248-254
[3]   Performances of homoepitaxial single crystal diamond in diagnostic x-ray dosimetry [J].
Garino, Y ;
Lo Giudice, A ;
Manfredotti, C ;
Marinelli, M ;
Milani, E ;
Tucciarone, A ;
Verona-Rinati, G .
APPLIED PHYSICS LETTERS, 2006, 88 (15)
[4]   Recent improvements on the use of CVD diamond ionisation chambers for radiotherapy applications [J].
Guerrero, M. J. ;
Tromson, D. ;
Descamps, C. ;
Bergonzo, P. .
DIAMOND AND RELATED MATERIALS, 2006, 15 (4-8) :811-814
[5]   Requirements for synthetic diamond devices for radiotherapy dosimetry applications [J].
Guerrero, MJ ;
Tromson, D ;
Rebisz, M ;
Mer, C ;
Bazin, B ;
Bergonzo, P .
DIAMOND AND RELATED MATERIALS, 2004, 13 (11-12) :2046-2051
[6]   DOSE-RATE DEPENDENCE OF A PTW DIAMOND DETECTOR IN THE DOSIMETRY OF A 6 MV PHOTON-BEAM [J].
HOBAN, PW ;
HEYDARIAN, M ;
BECKHAM, WA ;
BEDDOE, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (08) :1219-1229
[7]  
IAEA, 2000, 398 TRS IAEA
[8]   PREPARATION AND CHARACTERISTICS OF NATURAL DIAMOND NUCLEAR RADIATION DETECTORS [J].
KOZLOV, SF ;
STUCK, R ;
HAGEALI, M ;
SIFFERT, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) :160-170
[9]   A study of radiation dosimeters based on synthetic HPHT diamond [J].
Marczewska, B. ;
Kupriyanov, I. ;
Pal'yanov, Yu. ;
Nowak, T. ;
Olko, P. ;
Rebisz, M. ;
Waligorski, M. P. R. .
DIAMOND AND RELATED MATERIALS, 2007, 16 (02) :191-195
[10]   High performance 6LiF-diamond thermal neutron detectors [J].
Marinelli, Marco ;
Milani, E. ;
Prestopino, G. ;
Scoccia, M. ;
Tucciarone, A. ;
Verona-Rinati, G. ;
Angelone, M. ;
Pillon, M. ;
Lattanzi, D. .
APPLIED PHYSICS LETTERS, 2006, 89 (14)