Photon-burst analysis in two-photon fluorescence excitation flow cytometry

被引:0
作者
Hänninen, PE [1 ]
Soini, JT [1 ]
Soini, E [1 ]
机构
[1] Turku Univ, Dept Med Phys & Chem, FIN-20521 Turku, Finland
来源
CYTOMETRY | 1999年 / 36卷 / 03期
关键词
flow cytometry; rare-event detection; two-photon fluorescence excitation; photon burst detection; autocorrelation;
D O I
10.1002/(SICI)1097-0320(19990701)36:3<183::AID-CYTO6>3.0.CO;2-C
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We studied the use of a dramatically reduced testing zone in combination with two-photon excitation and photon-burst analysis in high-throughput rare-event detection simulation using a modified flow cytometer. Two-photon excitation measurements were performed with a mode-locked titanium:sapphire laser. Fluorescence emission was measured with a photon-counting avalanche photodiode. Measured signal was analysed offline by autocorrelation and burst detection methods. Test samples were composed of full blood and orange fluorescent polystyrene nanospheres mixed in full blood. Results show chat two-photon fluorescence excitation and time-correlation analysis provide a good signal-to-noise ratio for rare-event particle detection in a turbid sample environment. Cytometry 36:183-188, 1999. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 26 条
[1]   Scanning two-photon fluctuation correlation spectroscopy: Particle counting measurements for detection of molecular aggregation [J].
Berland, KM ;
So, PTC ;
Chen, Y ;
Mantulin, WW ;
Gratton, E .
BIOPHYSICAL JOURNAL, 1996, 71 (01) :410-420
[2]   ENRICHMENT OF FETAL CELLS FROM MATERNAL BLOOD BY HIGH-GRADIENT MAGNETIC CELL SORTING (DOUBLE MACS) FOR PCR-BASED GENETIC-ANALYSIS [J].
BUSCH, J ;
HUBER, P ;
PFLUGER, E ;
MILTENYI, S ;
HOLTZ, J ;
RADBRUCH, A .
PRENATAL DIAGNOSIS, 1994, 14 (12) :1129-1140
[3]   SINGLE-MOLECULE DETECTION - APPLICATIONS TO ULTRASENSITIVE BIOCHEMICAL-ANALYSIS [J].
CASTRO, A ;
SHERA, EB .
APPLIED OPTICS, 1995, 34 (18) :3218-3222
[4]  
CHEN CH, 1987, OPT COMMUN, V63, P1
[5]   2-PHOTON LASER SCANNING FLUORESCENCE MICROSCOPY [J].
DENK, W ;
STRICKLER, JH ;
WEBB, WW .
SCIENCE, 1990, 248 (4951) :73-76
[6]   Isolation of fetal trophoblasts and nucleated erythrocytes from the peripheral blood of pregnant women for prenatal diagnosis of fetal aneuploides [J].
Durrant, LG ;
Martin, WL ;
McDowall, KM ;
Liu, DTY .
EARLY HUMAN DEVELOPMENT, 1996, 47 :S79-S83
[7]   2-PHOTON SPECTRA OF AROMATIC-MOLECULES [J].
GOODMAN, L ;
RAVA, RP .
ACCOUNTS OF CHEMICAL RESEARCH, 1984, 17 (07) :250-257
[8]   PURIFICATION OF FETAL CELLS FROM MATERNAL BLOOD USING AN AVIDIN-BIOTIN IMMUNOAFFINITY COLUMN [J].
HALL, JM ;
ADAMS, S ;
WILLIAMS, S ;
REHSE, MA ;
LAYTON, TJ ;
MOLESH, DA .
FETAL CELLS IN MATERNAL BLOOD: PROSPECTS FOR NONINVASIVE PRENATAL DIAGNOSIS, 1994, 731 :115-127
[9]  
HANNINEN PE, 1994, J MICROSC-OXFORD, V176, P222
[10]   FETAL CELLS IN THE BLOOD OF PREGNANT-WOMEN - DETECTION AND ENRICHMENT BY FLUORESCENCE-ACTIVATED CELL SORTING [J].
HERZENBERG, LA ;
BIANCHI, DW ;
SCHRODER, J ;
CANN, HM ;
IVERSON, GM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1979, 76 (03) :1453-1455