The reliability of computed tomography (CT) values and dimensional measurements of the oropharyngeal region using cone beam CT: comparison with multidetector CT

被引:89
|
作者
Yamashina, A. [1 ]
Tanimoto, K. [1 ]
Sutthiprapaporn, P. [1 ,2 ]
Hayakawa, Y. [3 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed Sci, Dept Oral & Maxillofacial Surg, Hiroshima 730, Japan
[2] Khon Kaen Univ, Fac Dent, Dept Oral Diag, Khon Kaen, Thailand
[3] Kitami Inst Technol, Fac Engn, Dept Comp Sci, Kitami, Hokkaido, Japan
关键词
computed tomography; cone beam; computed tomography value; oropharynx;
D O I
10.1259/dmfr/45926904
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the reliability of cone beam CT (CBCT) values and dimensional measurements of oropharyngeal air spaces as compared with those of multidetector row CT (MDCT). Methods: A soft tissue equivalent phantom with different sized holes was used. The phantom was scanned using CBCT and MDCT. In addition, a volunteer was examined using both methods for clinical comparison. The CT data were retrieved to a personal computer and treated using image processing software for three-dimensional rendering and dimensional measurements. The CT values of air, water and soft tissues were measured experimentally and the CT values of air, fat and muscle were measured in a clinical case. The diameter of each hole drilled in the phantom was measured on CBCT and MDCT images using the software tool and digimatic callipers. Results: The CBCT values were quite different from the Hounsfield units obtained with a typical MDCT system. The standard deviations were almost ten times larger with CBCT. In vivo assessment showed that the CBCT values for fat had a wide range that partially overlapped the values for muscle. The measurement of distances greater than 4 mm was consistent for all methods. The difference for holes was less than 0.2 mm. Conclusions: The phantom study showed that CBCT provides limited quantitative CT values for each pixel on sliced images for differentiating air, water and soft tissues. However, the measurement of air spaces with CBCT was quite accurate.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 50 条
  • [31] Measurements of the coronary blood flow using Computed Tomography (CT)
    Grimme, S
    Krug, B
    Just, T
    Bovenschulte, H
    Paperno, S
    Lackner, K
    Cardio-Visions 2004: JUNGE EXZELLENZE IN DER KARDIOVASKULAREN FORSCHUNG, 2005, : 197 - 199
  • [32] A comparative study of accuracy of detection of surface osseous changes in the temporomandibular joint using multidetector CT and cone beam CT
    Zain-Alabdeen, E. H.
    Alsadhan, R. I.
    DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (03) : 185 - 191
  • [33] Cone-beam Computed Tomography of the Paranasal Sinuses: Comparison Study with Multidetector Computed Tomography
    Kei, P. L.
    Tan, J. S. P.
    Leong, J. L.
    Kwok, Y. M.
    Lim, W. E. H.
    Chan, L. L.
    HONG KONG JOURNAL OF RADIOLOGY, 2013, 16 (02): : 110 - 116
  • [34] Multidetector CT fluoroscopy and cone-beam CT-guided percutaneous transthoracic biopsy: comparison based on patient doses
    Strocchi, S.
    Colli, V.
    Conte, L.
    RADIATION PROTECTION DOSIMETRY, 2012, 151 (01) : 162 - 165
  • [35] Comparison of hand and semiautomatic tracing methods for creating maxillofacial artificial organs using sequences of computed tomography (CT) and cone beam computed tomography (CBCT) images
    Szabo, Bence T.
    Aksoy, Secil
    Repassy, Gabor
    Csomo, Krisztian
    Dobo-Nagy, Csaba
    Orhan, Kaan
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2017, 40 (06): : 307 - 312
  • [36] A comparative study of cone-beam CT and multidetector CT in the preoperative assessment of odontogenic cysts and tumors
    Shweel, Mohamed
    Amer, Maha Ishak
    El-Shamanhory, Ashraf Fathy
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2013, 44 (01): : 23 - 32
  • [37] A comparison of jaw dimensional and quality assessments of bone characteristics with cone-beam CT, spiral tomography, and multi-slice spiral CT
    Loubele, Miet
    Guerrero, Maria Eugenia
    Jacobs, Reinhilde
    Suetens, Paul
    van Steenberghe, Daniel
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (03) : 446 - 454
  • [38] Cone-Beam-CT Dose Simulation of Dental Cone-Beam-CT Using GMctdospp
    Voigt, J.
    Wulff, J.
    Guldner, C.
    Fiebich, M.
    MEDICAL PHYSICS, 2011, 38 (06) : 3399 - +
  • [39] Generating synthesized computed tomography (CT) from cone-beam computed tomography (CBCT) using CycleGAN for adaptive radiation therapy
    Liang, Xiao
    Chen, Liyuan
    Dan Nguyen
    Zhou, Zhiguo
    Gu, Xuejun
    Yang, Ming
    Wang, Jing
    Jiang, Steve
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):
  • [40] Comparison of Imaging performance: Cone beam CT versus conventional CT simulators
    Menon, G.
    Tambasco, M.
    MEDICAL PHYSICS, 2006, 33 (07) : 2663 - 2663