The reliability of computed tomography (CT) values and dimensional measurements of the oropharyngeal region using cone beam CT: comparison with multidetector CT

被引:89
|
作者
Yamashina, A. [1 ]
Tanimoto, K. [1 ]
Sutthiprapaporn, P. [1 ,2 ]
Hayakawa, Y. [3 ]
机构
[1] Hiroshima Univ, Grad Sch Biomed Sci, Dept Oral & Maxillofacial Surg, Hiroshima 730, Japan
[2] Khon Kaen Univ, Fac Dent, Dept Oral Diag, Khon Kaen, Thailand
[3] Kitami Inst Technol, Fac Engn, Dept Comp Sci, Kitami, Hokkaido, Japan
关键词
computed tomography; cone beam; computed tomography value; oropharynx;
D O I
10.1259/dmfr/45926904
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the reliability of cone beam CT (CBCT) values and dimensional measurements of oropharyngeal air spaces as compared with those of multidetector row CT (MDCT). Methods: A soft tissue equivalent phantom with different sized holes was used. The phantom was scanned using CBCT and MDCT. In addition, a volunteer was examined using both methods for clinical comparison. The CT data were retrieved to a personal computer and treated using image processing software for three-dimensional rendering and dimensional measurements. The CT values of air, water and soft tissues were measured experimentally and the CT values of air, fat and muscle were measured in a clinical case. The diameter of each hole drilled in the phantom was measured on CBCT and MDCT images using the software tool and digimatic callipers. Results: The CBCT values were quite different from the Hounsfield units obtained with a typical MDCT system. The standard deviations were almost ten times larger with CBCT. In vivo assessment showed that the CBCT values for fat had a wide range that partially overlapped the values for muscle. The measurement of distances greater than 4 mm was consistent for all methods. The difference for holes was less than 0.2 mm. Conclusions: The phantom study showed that CBCT provides limited quantitative CT values for each pixel on sliced images for differentiating air, water and soft tissues. However, the measurement of air spaces with CBCT was quite accurate.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 50 条
  • [21] Comparison of anterior and posterior trabecular bone microstructure of human mandible using cone-beam CT and micro CT
    Ibrahim, Norliza
    Parsa, Azin
    Hassan, Bassam
    van der Stelt, Paul
    Rahmat, Rabiah A.
    Ismail, Siti M.
    Aartman, Irene H. A.
    BMC ORAL HEALTH, 2021, 21 (01)
  • [22] Comparison of propagation-based CT using synchrotron radiation and conventional cone-beam CT for breast imaging
    Taba, Seyedamir Tavakoli
    Baran, Patrycja
    Nesterets, Yakov I.
    Pacile, Serena
    Wienbeck, Susanne
    Dullin, Christian
    Pavlov, Konstantin
    Maksimenko, Anton
    Lockie, Darren
    Mayo, Sheridan C.
    Quiney, Harry M.
    Dreossi, Diego
    Arfelli, Fulvia
    Tromba, Giuliana
    Lewis, Sarah
    Gureyev, Timur E.
    Brennan, Patrick C.
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2740 - 2750
  • [23] Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program
    Periago, Danielle R.
    Scarfe, William C.
    Moshiri, Mazyar
    Scheetz, James P.
    Silveira, Anibal M.
    Farman, Allan G.
    ANGLE ORTHODONTIST, 2008, 78 (03) : 387 - 395
  • [24] Metallic materials in the exomass impair cone beam CT voxel values
    Candemil, Amanda P.
    Salmon, Benjamin
    Freitas, Deborah Q.
    Ambrosano, Glaucia M. B.
    Haiter-Neto, Francisco
    Oliveira, Matheus L.
    DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (06)
  • [25] Variability of dental cone beam CT grey values for density estimations
    Pauwels, R.
    Nackaerts, O.
    Bellaiche, N.
    Stamatakis, H.
    Tsiklakis, K.
    Walker, A.
    Bosmans, H.
    Bogaerts, R.
    Jacobs, R.
    Horner, K.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1021):
  • [26] Accuracy of intraoral radiography, multidetector helical CT, and limited cone-beam CT for the detection of horizontal tooth root fracture
    Iikubo, Masahiro
    Kobayashi, Kaoru
    Mishima, Akira
    Shimoda, Shinji
    Daimaruya, Takayoshi
    Igarashi, Chinami
    Imanaka, Masahiro
    Yuasa, Masao
    Sakamoto, Maya
    Sasano, Takashi
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (05): : E70 - E74
  • [27] Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT
    Parsa, Azin
    Ibrahim, Norliza
    Hassan, Bassam
    van der Stelt, Paul
    Wismeijer, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (01) : E1 - E7
  • [28] The influence of exposure parameters on jawbone model accuracy using cone beam CT and multislice CT
    Vandenberghe, B.
    Luchsinger, S.
    Hostens, J.
    Dhoore, E.
    Jacobs, R.
    DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (06) : 466 - 474
  • [29] Comparison of micro-CT and cone beam CT on the feasibility of assessing trabecular structures in mandibular condyle
    Liang, Xin
    Zhang, Zuyan
    Gu, Jianping
    Wang, Zhihui
    Vandenberghe, Bart
    Jacobs, Reinhilde
    Yang, Jie
    Ma, Guowu
    Ling, Haibin
    Ma, Xuchen
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (05)
  • [30] A motion-compensated cone-beam CT using electrical impedance tomography imaging
    Pengpan, T.
    Smith, N. D.
    Qiu, W.
    Yao, A.
    Mitchell, C. N.
    Soleimani, M.
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (01) : 19 - 34