Robotic navigation for catheter ablation: benefits and challenges

被引:21
作者
Aagaard, Philip [1 ]
Natale, Andrea [2 ,3 ,4 ,5 ,6 ,7 ,8 ]
Di Biase, Luigi [1 ,2 ,3 ,9 ]
机构
[1] Montefiore Hosp, Albert Einstein Coll Med, Bronx, NY 10467 USA
[2] St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, Austin, TX USA
[3] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[4] Stanford Univ, Div Cardiol, Stanford, CA 94305 USA
[5] Case Western Reserve Univ, Cleveland, OH 44106 USA
[6] Calif Pacific Med Ctr, EP Serv, San Francisco, CA USA
[7] Scripps Clin, Intervent Electrophys, San Diego, CA USA
[8] Univ Texas Austin, Dell Med Sch, Austin, TX 78712 USA
[9] Univ Foggia, Dept Cardiol, Foggia, Italy
关键词
atrial fibrillation; atrial flutter; remote robotic ablation remote magnetic navigation catheter ablation; supraventricular tachycardia; ventricular tachycardia; REMOTE MAGNETIC NAVIGATION; VENTRICULAR OUTFLOW TRACT; PERSISTENT-ATRIAL-FIBRILLATION; PULMONARY VEIN ISOLATION; SUFFICIENT CURRENT CONTROVERSIES; INITIAL CLINICAL-EXPERIENCE; RANDOMIZED CONTROLLED-TRIAL; CONGENITAL HEART-DISEASE; IRRIGATED-TIP CATHETER; LONG-TERM OUTCOMES;
D O I
10.1586/17434440.2015.1052406
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Manual radio frequency (RF) ablation to restore a normal cardiac rhythm requires significant skill, manual dexterity and experience. In response to this, ablation methods and technologies have evolved rapidly in the past decade, including the development of remote navigation technologies. Today, two principal methods of remote navigation are available. One utilizes magnetic field vectors to navigate proprietary catheters, the other maneuvers standard catheters robotically. The main advantages of remote navigation include improved catheter stability, reduced fluoroscopy times and decreased total radiation exposure to both the patient and the operator. The main limitations include cost and longer procedure times. Remote magnetic navigation appears to have the best safety profile; however, its efficacy in creating lesions may be lower, which has been attributed to the soft-tip catheter used. Remote robotic navigation on the other hand, which uses regular catheter tips, is associated with a slightly higher overall complication rate, but higher efficacy. This article reviews the pros and cons of remote navigation for ablation of both atrial and ventricular substrates. Finally, it attempts to predict the direction of this field in the coming years.
引用
收藏
页码:457 / 469
页数:13
相关论文
共 109 条
[1]   Clinical usefulness of a multielectrode basket catheter for idiopathic ventricular tachycardia originating from right ventricular outflow tract [J].
Aiba, T ;
Shimizu, W ;
Taguchi, A ;
Suyama, K ;
Kurita, T ;
Aihara, N ;
Kamakura, S .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2001, 12 (05) :511-517
[2]   Acute and Long-Term Outcomes of Catheter Ablation Using Remote Magnetic Navigation in Patients With Congenital Heart Disease [J].
Akca, Ferdi ;
Bauernfeind, Tamas ;
Witsenburg, Maarten ;
Abkenari, Lara Dabiri ;
Cuypers, Judith A. ;
Roos-Hesselink, Lien W. ;
de Groot, Natasja M. S. ;
Jordaens, Luc ;
Szili-Torok, Tamas .
AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (03) :409-414
[3]   Safety and efficacy of the remote magnetic navigation for ablation of ventricular tachycardias-a systematic review [J].
Akca, Ferdi ;
Onsesveren, Ibrahim ;
Jordaens, Luc ;
Szili-Torok, Tamas .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (01) :65-71
[4]   First Evidence of Clinical Benefit of Robotically Driven Catheter Ablation or an Outlayer? [J].
Almendral, Jesus .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (11) :1423-1426
[5]  
[Anonymous], CIRCULATION ARRHYTHM
[6]   Initial clinical experience with a remote magnetic catheter navigation system for ablation of cavotricuspid isthmus-dependent right atrial flutter [J].
Arya, Arash ;
Kottkamp, Hans ;
Piorkowski, Christopher ;
Bollmann, Andreas ;
Gerdes-Li, Jin-Hong ;
Riahi, Sam ;
Esato, Masahiro ;
Hindricks, Gerhard .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2008, 31 (05) :597-603
[7]   Catheter ablation of atrial fibrillation using remote magnetic catheter navigation: a case-control study [J].
Arya, Arash ;
Zaker-Shahrak, Ruzbeh ;
Sommer, Phillip ;
Bollmann, Andreas ;
Wetzel, Ulrike ;
Gaspar, Thomas ;
Richter, Sergio ;
Husser, Daniela ;
Piorkowski, Christopher ;
Hindricks, Gerhard .
EUROPACE, 2011, 13 (01) :45-50
[8]   Catheter Ablation of Scar-Related Ventricular Tachycardia in Patients with Electrical Storm Using Remote Magnetic Catheter Navigation [J].
Arya, Arash ;
Eitel, Charlote ;
Bollmann, Andreas ;
Wetzel, Ulrike ;
Sommer, Phillipp ;
Gaspar, Thomas ;
Husser, Daniella ;
Piorkowski, Christopher ;
Hindricks, Gerhard .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (11) :1312-1318
[9]   Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar-related ventricular tachycardia [J].
Aryana, Arash ;
d'Avila, Andre ;
Heist, E. Kevin ;
Mela, Theofanie ;
Singh, Jagmeet P. ;
Ruskin, Jeremy N. ;
Reddy, Vivek Y. .
CIRCULATION, 2007, 115 (10) :1191-1200
[10]   Worldwide Experience with the Robotic Navigation System in Catheter Ablation of Atrial Fibrillation: Methodology, Efficacy and Safety [J].
Bai, Rong ;
Di Biase, Luigi ;
Valderrabano, Miguel ;
Lorgat, Faizel ;
Mlcochova, Hanka ;
Tilz, Roland ;
Meyerfeldt, Udo ;
Hranitzky, Patrick M. ;
Wazni, Oussama ;
Kanagaratnam, Prapa ;
Doshi, Rahul N. ;
Gibson, Douglas ;
Pisapia, Andre ;
Mohanty, Prasant ;
Saliba, Walid ;
Ouyang, Feifan ;
Kautzner, Josef ;
Gallinghouse, G. Joseph ;
Natale, Andrea .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (08) :820-826