COMPARISON BETWEEN DIFFERENT MANUFACTURERS' 2-D AND POINT SHEAR WAVE ELASTOGRAPHY TECHNIQUES IN STAGING LIVER FIBROSIS IN CHRONIC LIVER DISEASE USING LIVER BIOPSY AS THE REFERENCE STANDARD: A PROSPECTIVE STUDY

被引:8
作者
Fang, Cheng [1 ,6 ]
Rafailidis, Vasileios [1 ]
Konstantatou, Eleni [1 ]
Yusuf, Gibran T. [1 ]
Barrow, Ian [1 ]
Pagkalidou, Eirini [2 ]
Romanos, Odyssefs [1 ]
Agarwal, Kosh [3 ]
Quaglia, Alberto [3 ,4 ,5 ]
Sidhu, Paul S. [1 ]
机构
[1] King s Coll Hosp NHS Fdn Trust, Dept Radiol, London, England
[2] Aristotle Univ Thessaloniki, Fac Hlth Sci, Sch Med, Dept Hyg Social Prevent Med & Med Stat, Thessaloniki, Greece
[3] Kings Coll Hosp NHS Fdn Trust, Inst Liver Studies, London SE5 9RS, England
[4] Royal Free London NHS Fdn Trust, Dept Cellular Pathol, London, England
[5] UCL, UCL Canc Inst, London, England
[6] Kings Coll Hosp NHS Fdn Trust, Dept Radiol, Denmark Hill, London SE5 9RS, England
关键词
Point shear wave elastography; 2-D shear wave elastography; Shear wave elastography; Chronic liver disease; Liver biopsy; Liver fibrosis; ULTRASOUND ELASTOGRAPHY; REPRODUCIBILITY; STIFFNESS;
D O I
10.1016/j.ultrasmedbio.2022.06.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this study was to assess the utility of 2-D shear wave elastography (SWE) in assessing liver fibrosis in patients with chronic liver disease by comparing its performance with that of point shear wave elastography (pSWE) using liver histological staging as the reference standard. In this ethics committee-approved, single-institution prospective study, pSWE and 2-D SWE velocity measurements were obtained in 121 adult patients (age: 18-70 y, median: 45 y) immediately before a liver biopsy for chronic liver disease. Shear wave velocity (SWV) and Ishak scores were compared using the Kruskal-Wallis test, Spearman's correlation and receiver operating characteristic (ROC) curve analysis. Youden's index was used to determine the optimal cutoff point. There was no technical failure using pSWE and 2-D SWE. The mean difference for SWV between pSWE and 2-D SWE was 0.0223 (limits of agreement: -1.1009, 1.1145). Values for both pSWE and 2-D SWE were significantly correlated with fibrosis stage (Spearman's rho = 0.606, p < 0.0001; rho = 0.722, p < 0.001 respectively). The area under the ROC curve differentiating F >= 3 was 0.855 (95% confidence interval: 0.778-0.932) for pSWE and 0.884 (95% CI: 0.817-0.951) for 2-D SWE. The AUC for differentiating F >= 5 was 0.890 (95% CI: 0.826-0.954) for pSWE and 0.926 (95% CI: 0.88-0.973) for 2-D SWE. This study indicates that 2-D SWE provides feasible and accurate assessment of liver fibrosis, comparable to that provided by pSWE from two different manufacturers' machines. (C) 2022 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:2229 / 2236
页数:8
相关论文
共 22 条
[1]   INTRA- AND INTEROPERATOR REPRODUCIBILITY OF ACOUSTIC RADIATION FORCE IMPULSE (ARFI) ELASTOGRAPHY-PRELIMINARY RESULTS [J].
Bota, Simona ;
Sporea, Ioan ;
Sirli, Roxana ;
Popescu, Alina ;
Danila, Mirela ;
Costachescu, Dan .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (07) :1103-1108
[2]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[3]  
Dietrich CF, 2017, ULTRASCHALL MED, V38, pE16, DOI 10.1055/s-0043-103952
[4]   Ultrasound-based liver elastography in the assessment of fibrosis [J].
Fang, C. ;
Lim, A. ;
Sidhu, P. S. .
CLINICAL RADIOLOGY, 2020, 75 (11) :822-831
[5]   Ultrasound-based liver elastography: current results and future perspectives [J].
Fang, Cheng ;
Sidhu, Paul S. .
ABDOMINAL RADIOLOGY, 2020, 45 (11) :3463-3472
[6]   Reducing the Number of Measurements in Liver Point Shear-Wave Elastography: Factors that Influence the Number and Reliability of Measurements in Assessment of Liver Fibrosis in Clinical Practice [J].
Fang, Cheng ;
Jaffer, Ounali S. ;
Yusuf, Gibran T. ;
Konstantatou, Eleni ;
Quinlan, Daniel J. ;
Agarwal, Kosh ;
Quaglia, Alberto ;
Sidhu, Paul S. .
RADIOLOGY, 2018, 287 (03) :844-852
[7]   Reproducibility of 2-Dimensional Shear Wave Elastography Assessment of the Liver [J].
Fang, Cheng ;
Konstantatou, Eleni ;
Romanos, Odyssefs ;
Yusuf, Gibran T. ;
Quinlan, Daniel J. ;
Sidhu, Paul S. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (08) :1563-1569
[8]   Evaluation of Inter-System Variability in Liver Stiffness Measurements [J].
Ferraioli, Giovanna ;
De Silvestri, Annalisa ;
Lissandrin, Raffaella ;
Maiocchi, Laura ;
Tinelli, Carmine ;
Filice, Carlo ;
Barr, Richard G. .
ULTRASCHALL IN DER MEDIZIN, 2019, 40 (01) :64-75
[9]   Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity [J].
Ferraioli, Giovanna ;
Tinelli, Carmine ;
Zicchetti, Mabel ;
Above, Elisabetta ;
Poma, Gianluigi ;
Di Gregorio, Marta ;
Filice, Carlo .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) :3102-3106
[10]   Comparative study between pSWE and 2D-SWE techniques integrated in the same ultrasound machine, with Transient Elastography as the reference method [J].
Foncea, Camelia ;
Popescu, Alina ;
Lupusoru, Raluca ;
Fofiu, Renata ;
Sirli, Roxana ;
Danila, Mirela ;
Sporea, Ioan .
MEDICAL ULTRASONOGRAPHY, 2020, 22 (01) :15-21