COMPARISON BETWEEN DIFFERENT MANUFACTURERS' 2-D AND POINT SHEAR WAVE ELASTOGRAPHY TECHNIQUES IN STAGING LIVER FIBROSIS IN CHRONIC LIVER DISEASE USING LIVER BIOPSY AS THE REFERENCE STANDARD: A PROSPECTIVE STUDY

被引:8
作者
Fang, Cheng [1 ,6 ]
Rafailidis, Vasileios [1 ]
Konstantatou, Eleni [1 ]
Yusuf, Gibran T. [1 ]
Barrow, Ian [1 ]
Pagkalidou, Eirini [2 ]
Romanos, Odyssefs [1 ]
Agarwal, Kosh [3 ]
Quaglia, Alberto [3 ,4 ,5 ]
Sidhu, Paul S. [1 ]
机构
[1] King s Coll Hosp NHS Fdn Trust, Dept Radiol, London, England
[2] Aristotle Univ Thessaloniki, Fac Hlth Sci, Sch Med, Dept Hyg Social Prevent Med & Med Stat, Thessaloniki, Greece
[3] Kings Coll Hosp NHS Fdn Trust, Inst Liver Studies, London SE5 9RS, England
[4] Royal Free London NHS Fdn Trust, Dept Cellular Pathol, London, England
[5] UCL, UCL Canc Inst, London, England
[6] Kings Coll Hosp NHS Fdn Trust, Dept Radiol, Denmark Hill, London SE5 9RS, England
关键词
Point shear wave elastography; 2-D shear wave elastography; Shear wave elastography; Chronic liver disease; Liver biopsy; Liver fibrosis; ULTRASOUND ELASTOGRAPHY; REPRODUCIBILITY; STIFFNESS;
D O I
10.1016/j.ultrasmedbio.2022.06.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this study was to assess the utility of 2-D shear wave elastography (SWE) in assessing liver fibrosis in patients with chronic liver disease by comparing its performance with that of point shear wave elastography (pSWE) using liver histological staging as the reference standard. In this ethics committee-approved, single-institution prospective study, pSWE and 2-D SWE velocity measurements were obtained in 121 adult patients (age: 18-70 y, median: 45 y) immediately before a liver biopsy for chronic liver disease. Shear wave velocity (SWV) and Ishak scores were compared using the Kruskal-Wallis test, Spearman's correlation and receiver operating characteristic (ROC) curve analysis. Youden's index was used to determine the optimal cutoff point. There was no technical failure using pSWE and 2-D SWE. The mean difference for SWV between pSWE and 2-D SWE was 0.0223 (limits of agreement: -1.1009, 1.1145). Values for both pSWE and 2-D SWE were significantly correlated with fibrosis stage (Spearman's rho = 0.606, p < 0.0001; rho = 0.722, p < 0.001 respectively). The area under the ROC curve differentiating F >= 3 was 0.855 (95% confidence interval: 0.778-0.932) for pSWE and 0.884 (95% CI: 0.817-0.951) for 2-D SWE. The AUC for differentiating F >= 5 was 0.890 (95% CI: 0.826-0.954) for pSWE and 0.926 (95% CI: 0.88-0.973) for 2-D SWE. This study indicates that 2-D SWE provides feasible and accurate assessment of liver fibrosis, comparable to that provided by pSWE from two different manufacturers' machines. (C) 2022 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:2229 / 2236
页数:8
相关论文
共 50 条
  • [1] Comparison between Two-Dimensional and Point Shear Wave Elastography Techniques in Evaluating Liver Fibrosis Using Histological Staging as the Reference Standard: A Prospective Pilot Study
    Lee, Sang Min
    Ha, Hong Il
    Lee, In Jae
    Lee, Kwanseop
    Lee, Jung Woo
    Park, Ji Won
    Kim, Sung-Eun
    Kwon, Mi Jung
    Choe, Ji-Young
    Yoon, Sam-Youl
    Yeo, Seung-Gu
    Kim, Min-Jeong
    DIAGNOSTICS, 2023, 13 (09)
  • [2] COMPARISON OF SOUND TOUCH ELASTOGRAPHY, SHEAR WAVE ELASTOGRAPHY AND VIBRATION-CONTROLLED TRANSIENT ELASTOGRAPHY IN CHRONIC LIVER DISEASE ASSESSMENT USING LIVER BIOPSY AS THE "REFERENCE STANDARD"
    Gatos, Ilias
    Drazinos, Petros
    Yarmenitis, Spyros
    Theotokas, Ioannis
    Zoumpoulis, Pavlos S.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (04) : 959 - 971
  • [3] COMPARISON OF 2-D SHEAR WAVE ELASTOGRAPHY AND POINT SHEAR WAVE ELASTOGRAPHY FOR ASSESSING LIVER FIBROSIS
    Zhou, Xiaozhuan
    Rao, Jiawei
    Wu, Xukun
    Deng, Ronghai
    Ma, Yi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (03) : 408 - 427
  • [4] Comparison of Visual Transient Elastography and Shear Wave Elastography in Evaluating Liver Fibrosis in Patients with Chronic Liver Disease
    Yang, Jiali
    Li, Jiawu
    Ye, Guilin
    Luo, Yan
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 3553 - 3561
  • [5] COMPARATIVE STUDY BETWEEN THE DIAGNOSTIC PERFORMANCE OF POINT AND 2-D SHEAR-WAVE ELASTOGRAPHY FOR THE NON-INVASIVE ASSESSMENT OF LIVER FIBROSIS IN PATIENTS WITH CHRONIC HEPATITIS C USING TRANSIENT ELASTOGRAPHY AS REFERENCE
    Baldea, Victor
    Sporea, Ioan
    Lupusoru, Raluca
    Bende, Felix
    Mare, Ruxandra
    Popescu, Alina
    Sirli, Roxana
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (11) : 2979 - 2988
  • [6] Prospective comparison of transient, point shear wave, and magnetic resonance elastography for staging liver fibrosis
    Lefebvre, Thierry
    Wartelle-Bladou, Claire
    Wong, Philip
    Sebastiani, Giada
    Giard, Jeanne-Marie
    Castel, Helene
    Murphy-Lavallee, Jessica
    Olivie, Damien
    Ilinca, Andre
    Sylvestre, Marie-Pierre
    Gilbert, Guillaume
    Gao, Zu-Hua
    Nguyen, Bich N.
    Cloutier, Guy
    Tang, An
    EUROPEAN RADIOLOGY, 2019, 29 (12) : 6477 - 6488
  • [7] ASSESSMENT OF LIVER FIBROSIS WITH 2-D SHEAR WAVE ELASTOGRAPHY IN COMPARISON TO TRANSIENT ELASTOGRAPHY AND ACOUSTIC RADIATION FORCE IMPULSE IMAGING IN PATIENTS WITH CHRONIC LIVER DISEASE
    Gerber, Ludmila
    Kasper, Daniela
    Fitting, Daniel
    Knop, Viola
    Vermehren, Annika
    Sprinzl, Kathrin
    Hansmann, Martin L.
    Herrmann, Eva
    Bojunga, Joerg
    Albert, Joerg
    Sarrazin, Christoph
    Zeuzem, Stefan
    Friedrich-Rust, Mireen
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (09) : 2350 - 2359
  • [8] Comparison between shear wave elastography and serological findings for the evaluation of fibrosis in chronic liver disease
    Liaqat, Mahjabeen
    Siddique, Kashif
    Yousaf, Imran
    Bacha, Raham
    Farooq, S. Muhammad Yousaf
    Gilani, Syed Amir
    JOURNAL OF ULTRASONOGRAPHY, 2021, 21 (86) : E186 - E193
  • [9] Comparison of Visual Transient Elastography, Vibration Controlled Transient Elastography, Shear Wave Elastography and Sound Touch Elastography in Chronic liver Disease assessment using liver biopsy as 'Gold Standard'
    Gatos, Ilias
    Yarmenitis, Spyros
    Theotokas, Ioannis
    Koskinas, John
    Manesis, Emmanuel
    Zoumpoulis, Spyros P.
    Zoumpoulis, Pavlos S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 157
  • [10] Comparison of Transient Elastography and Point Shear Wave Elastography for Analysis of Liver Stiffness: A Prospective Study
    Losurdo, Giuseppe
    Ditonno, Ilaria
    Novielli, Domenico
    Celiberto, Francesca
    Iannone, Andrea
    Castellaneta, Antonino
    Dell'Aquila, Paola
    Ranaldo, Nunzio
    Rendina, Maria
    Barone, Michele
    Ierardi, Enzo
    Di Leo, Alfredo
    DIAGNOSTICS, 2024, 14 (06)